30
Views
3
CrossRef citations to date
0
Altmetric
Anatomical Pathology

Comparative study between Pap smear cytology and FTIR spectroscopy: a new tool for screening for cervical cancer

, , &
Pages 600-603 | Received 25 Jun 2007, Accepted 22 Nov 2007, Published online: 06 Jul 2009
 

Summary

Aims: To evaluate Fourier transform infrared (FTIR) spectroscopy as new tool for screening of cervical cancer in comparison with cervical cytology.

Methods: A total of 800 cervical scrapings were taken by cytobrush and placed in ThinPrep medium. The samples were dried over infrared transparent matrix. Beams of infrared light were directed at the dried samples at frequency of 4000 to 400 cm-1. The absorption data were produced using a Spectrum BX II FTIR spectrometer. Data were compared with the reference absorption data of known samples using FTIR spectroscopy software. FTIR spectroscopy was compared with cytology (gold standard).

Results: FTIR spectroscopy could differentiate normal from abnormal cervical cells in the samples examined. The sensitivity was 85%, specificity 91%, positive predictive value 19.5% and negative predictive value of 99.5%.

Conclusion: This study suggests that FTIR spectroscopy could be used as an alternative method for screening for cervical cancer.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.