Purpose

To evaluate lower lid position and tear meniscus in peripheral idiopathic facial nerve palsy (FNP).

Methods

A prospective study enrolled patients with peripheral idiopathic FNP and epiphora. Data were collected on patient demographics, House-Brackmann (HB) scale, digital photographs of the face, and tear meniscus at the 1st, 30, and 90 day after onset of FNP. Marginal reflex distance to the upper (MRD1) and lower eyelid (MRD2) were evaluated using ImageJ software. Anterior segment optical coherence tomography (OCT) was performed to measure the tear menis- cus. P< .05 was considered statistically significant.

Results

Sixteen patients were evaluated. The HB scale at presentation was grade III in six patients (37.5%). At 90 day, nine patients (56.25%) were grade I-normal. Three (18.7%) had upper lid retraction, three (18.7%) upper eyelid asymmetry and 7 (43.75%), lower eyelid retraction. The difference between MRD2-FNP with MRD2-healthy side was 0.51 ± 1.9 mm at the 1st visit, decreasing to 0.09 ± 1.47 mm at 90 days (P= .877). Tear meniscus measurements were significantly higher in FNP at the 1st visit (P= .001). The decrease in MRD2 was statistically correlated with the reduction of the tear meniscus area (TMA) (r = 0.67; P= .007) at 90 days. No correlation was found between HB and TMA. There is a difference in TMA between age groups at the 1st day(p= .009). Eldest group had higher HB scales.

Conclusion

Quantitative evaluation of eyelid position and tear meniscus are effective to document the evolution of FNP and can serve as a clue of orbicularis recovery.

Acknowlegdment

To all who collaborated in patient data collection and the English Editor (Proofreading).

Disclosure statement

No potential conflict of interest was reported by the author(s).

Additional information

Funding

The author(s) reported there is no funding associated with the work featured in this article.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.