Amplitude of movements with conical or spherical implants in anophthalmic socket

ORCID Icon, ORCID Icon, ORCID Icon & ORCID Icon
Pages 708-716 | Received 02 Apr 2021, Accepted 23 Oct 2021, Published online: 28 Nov 2021
 

ABSTRACT

Purpose: To evaluate the amplitude of movement in anophthalmic sockets reconstructed with conical or spherical orbital implants with and without an external ocular prosthesis (EOP), and whether the fornix depth could play a role. Methods: Prospective observational study involving unilateral anophthalmic sockets evaluated the amplitude of movement with conical (20 subjects) or spherical (16) non-porous orbital implants, with and without an EOP, having the contralateral eye as the control group. Standardized photographs were obtained in the four gaze directions and measurements were performed using the Image J software. The upper and lower fornix depths were measured using rulers. Results: Compared to the contralateral eye, the median movement amplitude without EOP was smaller with conical implants in supraduction (−0.88 mm, p=0.008), abduction (−2.26 mm, p<0.001) and adduction (−0.91 mm, p=0.008). Spherical implants had reduced movement only in abduction (−2.63 mm, p<0.001). Conical and spherical implants had similar amplitudes of movement in all versions, and were always smaller compared to the control. The median movement amplitude with the EOP was −3.05 mm (p=0.001) than without the EOP in abduction and −2.07 mm (p=0.020) in adduction, regardless of implant format. The fornix depth did not affect the orbital implants or EOP movement amplitude’s median. Conclusion: Conical and spherical implants provide similar amplitude of movement and fornix depth did not have an influence on it. The amplitude of movement was significantly limited compared to the contralateral eye and was even more reduced if the EOP was in place with conical or spherical implant formats.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Data availability statement

The authors confirm that the data supporting the findings of this study are available within the article.

Additional information

Funding

The author(s) reported there is no funding associated with the work featured in this article.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.