Abstract

Background

Mechanical obstruction is the most common cause of shunt failure for hydrocephalic patients. However, the diagnosis is extremely challenging and often requires invasive testing methods. Thus, a simple and non-invasive technique is in urgent need to predict the intracranial pressure (ICP) of hydrocephalic patients during their post-surgical follow-up, which could help neurosurgeons to determine the conditions of the shunt system.

Materials and methods

Two groups of patients were enrolled in the current study. In group I, patients were enrolled as they were diagnosed with high ICP hydrocephalus and received shunt surgery. The shunt valve pressures were taken for their post-surgical ICP. Meanwhile, the participants of group II exhibited abnormally increased lumbar puncture opening pressure (LPOP; from 180 to 400 mmH2O). Both the ICP and LPOP were used to match with their corresponding tympanic membrane temperature (TMT).

Results

When patients’ ICP were in the normal range (group I, from 50 to 180 mmH2O), the TMT correlated with ICP in a linear regression model (R2=0.59, p<0.001). Interestingly, when patients exhibited above-normal ICP (LPOP was from 180 to 400 mmH2O), their TMT fit well with the ICP in a third-order polynomial regression (R2=0.88). When the ICP was 287.98 mmH2O, the TMT approached the vertex, which was 38.54 °C. Based on this TMT-ICP algorithm, we invented a non-invasive ICP monitor system. Interestingly, a tight linear correlation was detected between the ICP data drawn from the non-invasive device and Codman ICP monitoring system (R2=0.93, p<0.01).

Conclusions

We believe the TMT-ICP algorithm (the Y-Jiang model) could be used for preliminary prediction of shunt malfunction as well as monitoring ICP changes.

Acknowledgment

We want to express our sincere acknowledgment to all the participants and those who helped in completing the current study.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.