459
Views
8
CrossRef citations to date
0
Altmetric
Methods Paper

Development of a high-yield expression and purification system for platelet factor 4

, , , , &
Pages 249-256 | Received 24 Apr 2017, Accepted 02 Aug 2017, Published online: 27 Nov 2017
 

Abstract

Heparin-induced thrombocytopenia (HIT) is an adverse drug reaction characterized by IgG antibodies bound to complexes of platelet factor 4 (PF4) and heparin. The majority of diagnostic tests for HIT rely on an exogenous source of PF4 to identify anti-PF4/heparin antibodies. These include the PF4-dependent enhanced serotonin release assay (PF4-SRA) among others. Using a bacterial expression system, we developed a novel and efficient method of producing recombinant human PF4 (rhPF4) that is biochemically and antigenically similar to platelet-derived human PF4. rhPF4 was produced using the pET expression system in the BL21(DE3) strain of Escherichia coli. The system was optimized for protein expression using isopropyl β-D-1-thiogalactopyranoside at different induction temperatures and incubation times. rhPF4 solubility was improved by using different detergents during cell lysis and by purifying with heparin affinity and ion exchange chromatography. Biochemical characteristics of rhPF4 were investigated using mass spectrometry, SDS-PAGE analysis, and gel filtration chromatography and compared to platelet-derived PF4. Antigenic and functional characteristics of rhPF4 were studied using the anti-PF4/heparin EIA and the PF4-SRA. Using this method, we could produce 11.4 ± 0.6 mg of pure rhPF4 per liter of bacterial culture. Absorbance readings from the anti-PF4/heparin EIA using platelet-derived and rhPF4 were highly correlated (n = 194; r = 0.9545, p < 0.0001); and functional release of serotonin in the PF4-SRA induced by anti-PF4/heparin antibodies was similar to either platelet-derived or rhPF4 and heparin (r = 0.9597, p < 0.0001). Our method of rhPF4 production is efficient and does not rely on a source of platelets. The rhPF4 purification method described produces greater yields at a lower cost than other current methods. The application of this method can improve the efficiency of biochemical investigations and HIT diagnostic testing by supplying sufficient amounts of PF4.

Funding

Ishac Nazy holds a McMaster University, Department of Medicine, Internal Career Research Award. Funding support for this work was provided by a grant from the Canadian Institute for Health Research awarded to Dr. Ishac Nazy (#363046).

Declaration of interest

Conflict of interest disclosure: the authors declare no competing financial interests.

Additional information

Notes on contributors

Ishac Nazy

Contribution: AH carried out the described studies, analyzed data, and wrote the manuscript. IN designed the research, interpreted data, and wrote the manuscript. JWS and JCM assisted with experimentation, provided technical assistance, and helped write the manuscript. DMA and JGK designed the research and helped write the manuscript. All authors reviewed and approved the final version of the manuscript.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.