91
Views
11
CrossRef citations to date
0
Altmetric
Original

Analysis of γ-rays induced chromosome aberrations: A fingerprint evaluation with a combination of pan-centromeric and pan-telomeric probes

, , , , &
Pages 869-875 | Received 07 Apr 2006, Accepted 28 Aug 2006, Published online: 03 Jul 2009
 

Abstract

Purpose: To evaluate the types of induced chromosome aberrations after the exposure of peripheral blood to γ-rays by the simultaneous detection of all centromeres and telomeres; and to analyse the suitability of different radiation fingerprints for the assessment of radiation quality in cases of recent exposures.

Material and methods: Peripheral blood samples were irradiated at 2, 4 and 6 Gy of γ-rays. Cytogenetic analysis was carried out by fluorescence in situ hybridization (FISH) technique with pan-centromeric and peptide nucleic acid (PNA)-telomeric DNA probes. Cells were analysed using a Cytovision® FISH workstation, chromosome aberrations and the length of the acentric fragments were recorded.

Results: The total number of the incomplete chromosome elements was 276. The ratio between incomplete elements and multicentrics was 0.38. The number of acentrics was 1096, 71% were complete acentrics, 15% incomplete acentrics, and 14% interstitial fragments. The relative length of complete, incomplete and interstitial acentrics fragments were 2.70 ± 0.04, 1.91 ± 0.07, and 1.42 ± 0.04 respectively. The mean value of the F-ratio was 11.5 higher than the one, 5.5, previously obtained for α-particles. For the G-ratio there was no difference between γ-rays and α-particles, 2.8 and 2.8 respectively. The mean value of the H-ratio for γ-rays, 0.25, was lower than for α-particles 0.40.

Conclusion: The results support that the percentage of incomplete chromosome aberrations depends on radiation type; low-linear energy transfer (LET) radiation would produces less incomplete aberrations than high-LET radiation. The F- and H-ratios seem to be good indicators of radiation quality, although a real estimation of the H-ratio is only possible using pan-telomeric probes.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.