160
Views
9
CrossRef citations to date
0
Altmetric
Original Contributions

Threats to Life in Residential Structure Fires

, MD, , MA, PA-C, EMT-P, , MD & , MD
Pages 297-301 | Received 13 Dec 2007, Accepted 04 Mar 2008, Published online: 02 Jul 2009
 

Abstract

Introduction. Firefighters are taught that heat, oxygen deprivation, andcarbon monoxide (CO) are the primary threats to life in residential structure fires, andthey are taught to search for victims on the fire floor first, andthen floors above. The objective of this study was to gather data regarding oxygen, CO, andheat conditions inside a realistic house fire, to examine the validity of these teachings. Methods. During six live-burn training evolutions in a two-story wood-frame house, metering for oxygen levels, CO levels, andtemperature was conducted. Except where noted, all readings were taken 24 inches off the floor, to simulate the location of a crawling victim or firefighter. Readings were hand-recorded on a convenience basis by firefighters stationed outside the building, near the meters. Results. Of the 35 oxygen levels recorded, the lowest was 18.2%, with only 12 readings below 20%. Three of 16 first-floor readings were below 20%, whereas nine of 19 second-floor readings were below 20% (p = 0.07). First- andsecond-floor readings were comparable (mean 20.3% vs. 19.9%, p = 0.11). Except for one reading of 1,870 ppm, all CO readings at the ceiling exceeded the 2,000-ppm limit of the meters. Of the 34 CO levels recorded 24 inches off the floor, 29 (76%) exceeded the permissible exposure limit of 50 ppm, with the highest reading being 1,424 ppm, well above the “immediately dangerous to life andhealth” level of 1,200 ppm. None of the 20 CO levels recorded on the first floor exceeded the 30-minute exposure limit of 800 ppm, whereas seven of 14 second-floor readings exceeded this limit (p < 0.001). While ceiling temperatures frequently exceeded the 1,000°F limit of the meters, none of 16 readings taken 24 inches off the floor exceeded 137°F. First- andsecond-floor temperatures were comparable (mean 88.5°F vs. 90.1°F, p = 0.9). Conclusions. In residential structure fires, CO poses a greater threat to victims andfirefighters than does oxygen deprivation or heat. Emergency medical services personnel should consider CO toxicity in all fire victims. Conditions on the floor above a fire are at least as adverse as those on the fire floor.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.