Medication Errors in Pediatric Patients after Implementation of a Field Guide with Volume-Based Dosing

, , &
Pages 213-220 | Received 20 Jun 2021, Accepted 02 Jan 2022, Published online: 27 Jan 2022
 

Abstract

Background

Several studies have demonstrated the high frequency of medication errors in pediatric patients by prehospital providers during both patient care and simulation. In 2015, our hospital-based urban EMS system introduced the HandtevyTM Field Guide that provides precalculated pediatric doses in milliliters (mL) by patient age. We hypothesized that implementation of the Field Guide would increase the percentage of correct pediatric medication doses to greater than 85%.

Methods

We performed a single center retrospective cohort study of medications administered to patients < 13 years of age from August 2017 to July 2019 compared to 2014 baseline data through electronic medical record review. We excluded nebulized medications and online medication direction cases. Our primary outcome was the percentage of correct doses defined as a dose within 80–120% of the Field Guide dose recommendation. Each dosing error was reviewed by two investigators.

Results

We analyzed 483 drug administrations in 375 patients for the Field Guide study period. Doses were correct in 89.4% of medication administrations with 68.5% reportedly administered exactly as dictated by the Field Guide compared to 51.1% in the baseline period (p < 0.001). During the Field Guide study period, the following medications had 100% appropriate dosing: adenosine, dextrose 10%, diphenhydramine, epinephrine 1:10,000, glucagon, naloxone and oral ondansetron. Overdoses accounted for 4.4% of medication errors and underdoses accounted for 6.2% of medications errors. The most overdosed medications were intranasal (IN) midazolam (11.8%) and intravenous fentanyl (9.4%). The most underdosed medications were IN midazolam (23.5%) and intramuscular epinephrine 1:1000 (12.5%). The highest percentage of errors (20%) were seen in the zero to one-year-old age group.

Conclusion

After implementation of a precalculated mL dose system by patient age for EMS providers, most pediatric medications were reportedly administered within the appropriate dose range. A field guide with precalculated doses (in mL) may be an effective tool for reducing pediatric medication dosing errors by EMS providers.

Disclosure Statement

The authors report no conflict of interest.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.