159
Views
1
CrossRef citations to date
0
Altmetric
Original Research

Disinfection of Stethoscope and Non-Infrared Thermometer: Practices of Physicians in Ethiopia in the Era of COVID-19

ORCID Icon, ORCID Icon, , &
Pages 3245-3257 | Published online: 05 Jan 2021
 

Abstract

Background

Stethoscopes and non-infrared thermometers are the customary medical equipment used by the physicians on a daily basis, among various patients. With the rise of potential infections in the healthcare facilities and the transmission nature of the current COVID-19 pandemic, consistent and correct disinfections of these devices after each use should not be pardoned. This study, therefore, aimed to assess the level of stethoscope and non-infrared thermometer disinfection practices among physicians involved in direct patient contact during the COVID-19 pandemic.

Methods

A web-based cross-sectional survey was conducted among physicians working in Ethiopia to assess their practice of stethoscope and non-infrared thermometer disinfection. The online survey was circulated using an anonymous and self-reporting questionnaire via Google form with a consent form appended to it. The developed Google form link was shared with physicians through their email addresses and social media pages. A descriptive summary was computed and presented by tables and figures. Multivariable logistic regression model was used to identify factors associated stethoscope and non-infrared thermometer after every use.

Results

The proportion of stethoscope and non-infrared thermometer disinfections after every use was 13.9% (95% CI: 10.9–17.6) and 20.4% (95% CI: 16.7–24.5), respectively. Taking COVID-19 training (AOR: 2.52; 95% CI: 1.29–4.92) and the availability of stethoscope disinfection materials at the workplace (AOR: 3.03; 95% CI: 1.29–7.10) were significantly increased the odds of stethoscope disinfection after every use. The odds of stethoscope disinfection after every use was significantly decreased for those who reported the use of shared stethoscope (AOR: 0.34; 95% CI: 0.12–0.92).

Conclusion

Only a wee share of the respondents reported that they have disinfected their stethoscopes and non-infrared thermometers after every use – possibly jeopardizing both patients and clinicians safety, particularly during the COVID-19 pandemic.

Acknowledgments

We would like to thank all study participants take part in this survey.

Abbreviations

AOR, adjusted odds ratio; CI, confidence interval; COVID-19, coronavirus disease; WHO, World Health Organization; COR, crudes odds ratio.

Data Sharing Statement

Data are available from the corresponding author upon a reasonable request.

Author Contributions

All authors contributed to data analysis, drafting or revising the article, have agreed on the journal to which the article will be submitted, gave final approval of the version to be published, and agree to be accountable for all aspects of the work.

Disclosure

The authors report no conflicts of interest in this work.

Additional information

Funding

There is no funding to report.