1,477
Views
43
CrossRef citations to date
0
Altmetric
Original Articles

Automatic delineation for replanning in nasopharynx radiotherapy: What is the agreement among experts to be considered as benchmark?

, , , , , , , , , & show all
Pages 1417-1422 | Received 06 May 2013, Accepted 01 Jun 2013, Published online: 19 Aug 2013
 

Abstract

Background and purpose. Anatomic changes during head and neck radiotherapy require replanning. The primary aim of this study is the definition of the agreement among experts in the head and neck automatic delineation frame to use as benchmark. The secondary goal is to assess the reliability of automatic delineation for nasopharynx radiotherapy and time saving. Material and methods. A computed tomography (CT) scan was acquired in 10 nasopharynx patients along intensity-modulated radiotherapy (IMRT) treatment for replanning. Deformable registration with replanning autocontouring of the structures was performed using VelocityAI 2.3© software defining Structure Set A. The optimization of these contours was obtained through revision by a skilled operator, drawing Structure Set B. An ex novo Structure Set C was segmented on the replanning CT-scan by an expert delineation team. The mean Dice's Similarity Index (mDSI) was calculated between Structure Set A and B, A and C, and between B and C for each volume. All segmentation times for organs at risk (OARs) and clinical target volume (CTV) were recorded and compared. Results. We validated the replanning autocontoured Structure Sets for 10 patients. For volumetric analysis we observed mDSI values of 0.87 for the OARs, 0.70 for nodes, 0.90 for CTV in the Structure Set A-B comparison and respectively of 0.74, 0.63 and 0.78 for the Structure Set A-C one, and 0.78, 0.78 and 0.85 for Structure Set B-C, which represents the existing expert based benchmark. We calculated a mean saved time in Structure Set B of 30 minutes. Conclusions. Autocontouring procedures offer considerable segmentation time saving with acceptable reliability of the contours, even if an independent check procedure for their optimization is still required to increase their adherence to referential benchmark gold standard among experts, which stands at a 0.80 DSI value.

Declaration of interest: The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the paper.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.