Initial clinical experience using a novel laparoscopy assistant

, &
Pages 167-173 | Received 02 Jun 2010, Accepted 26 Jul 2010, Published online: 25 Nov 2010
 

Abstract

This article presents the first clinical and experimental experiences of the PMASS (Postural Mechatronic Assistance Solo Surgery) from a prospective study carried on on thirteen laparoscopic procedures. Also, their advantages and disadvantages are identified. The PMASS is a system with three articulations; two articulations are passive and one is active; this handles the optic in real time, reducing the latency time by spatial relocation. The surgeons assisted themselves visually in 13 surgical procedures, having direct and intuitive control in real time of the laparoscopic vision field using the PMASS. The surgical and delay time was documented for each surgery. The surgical procedures were: Laparoscopic appendicectomy, ovarian cystectomy and laparoscopic sterilization. In all procedures, surgeons were able to auto-navigate in real time and there was no visual tremor while using the system. The global average times taken to perform the self-assisted surgery with the PMASS for the laparoscopic appendicectomies were 45 ± 4.5 minutes, ovarian cystectomies 49 ± 3.5 minutes and for the laparoscopic sterilization 22 ± 2 minutes. The approximate set-up time of PMASS was one minute, and removal almost a minute (the time required by the surgeon to remove the harness after completing the surgery). The laparoscope itself disengages from the PMASS in a couple of seconds approximately. There were no transoperative or postoperative complications during the procedures. Thirteen laparoscopic procedures were performed, the design of the mechatronic assistance allowed the surgeon to self-assist visually in real time and in an autonomous way in the solo-surgery mode, without compromising the surgical performance and the morbidity. Additionally, the latency times are also reduced by space relocation and coupling of the telescope.

Acknowledgment

The authors want to express their Acknowledgment to CONACYT México (National Council for Science and Technology) for their support.

Declaration of interest: The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the paper.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.