ORIGINAL ARTICLE

Experimental study of an adjustable-length titanium ossicular prosthesis in a temporal bone model

, &
Pages 33-37 | Received 08 Jan 2004, Accepted 18 Mar 2004, Published online: 08 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

Mark Praetorius, Sabrina S. Kirchenbauer, Stefanie Buss, Christoph Klingmann, Peter K. Plinkert & Ingo Baumann. (2010) First experiences with a new adjustable length titanium ossicular prosthesis (ALTO). Acta Oto-Laryngologica 130:11, pages 1237-1241.
Read now

Articles from other publishers (15)

Merlin Schär, Ivo Dobrev, Christof Röösli, Alexander M. Huber & Jae Hoon Sim. (2023) Effects of preloads on middle-ear transfer function and acoustic reflex in ossiculoplasty with PORP. Hearing Research 430, pages 108709.
Crossref
Eric M. Kraus, Gregory B. Russell, Sarah J. Allen & Sarah A. Pearson. (2022) Long-Term Hearing Results of Endoskeletal Ossicular Reconstruction in Chronic Ears Using Titanium Prostheses Having a Helical Coil: Part 1—Kraus K-Helix Crown, Incus to Stapes. Otology & Neurotology 43:9, pages 1056-1064.
Crossref
Mario Milazzo, Pieter G.G. Muyshondt, Josephine Carstensen, Joris J.J. Dirckx, Serena Danti & Markus J. Buehler. (2020) De novo topology optimization of total ossicular replacement prostheses. Journal of the Mechanical Behavior of Biomedical Materials 103, pages 103541.
Crossref
Thomas Stoppe, Matthias Bornitz, Nikoloz Lasurashvili, Kirsten Sauer, Thomas Zahnert, Karim Zaoui & Thomas Beleites. (2018) Function, Applicability, and Properties of a Novel Flexible Total Ossicular Replacement Prosthesis With a Silicone Coated Ball and Socket Joint. Otology & Neurotology 39:6, pages 739-747.
Crossref
Rafal Rusinek, Marcin Szymanski & Grzegorz Teresinski. (2018) Middle ear vibrations with SMA prosthesis. Experimental research. MATEC Web of Conferences 148, pages 12001.
Crossref
Rafal Rusinek, Jerzy Warminski, Andrzej Weremczuk & Marcin Szymanski. (2018) Analytical solutions of a nonlinear two degrees of freedom model of a human middle ear with SMA prosthesis. International Journal of Non-Linear Mechanics 98, pages 163-172.
Crossref
Luis A. Vallejo, María T. Manzano, Antonio Hidalgo, Alberto Hernández, Juan Sabas, Hugo Lara, Elisa Gil-Carcedo & David Herrero. (2017) Análisis experimental mediante vibrometría láser doppler en huesos temporales de cadáver fresco de una nueva prótesis de maleovestibulopexia. Acta Otorrinolaringológica Española 68:2, pages 69-79.
Crossref
Luis A. Vallejo, María T. Manzano, Antonio Hidalgo, Alberto Hernández, Juan Sabas, Hugo Lara, Elisa Gil-Carcedo & David Herrero. (2017) A New Malleostapedotomy Prosthesis. Experimental Analysis by Laser Doppler Vibrometer in Fresh Cadaver Temporal Bones. Acta Otorrinolaringologica (English Edition) 68:2, pages 69-79.
Crossref
Rusinek Rafal, Marcin Szymanski & Pawel Lajmert. Vibration of middle ear with shape memory prosthesis - Experimental and numerical study. Vibration of middle ear with shape memory prosthesis - Experimental and numerical study.
Peter K. GottliebXiping Li, Ashkan MonfaredNikolas BlevinsSunil Puria. (2016) First results of a novel adjustable-length ossicular reconstruction prosthesis in temporal bones. The Laryngoscope 126:11, pages 2559-2564.
Crossref
Masahiro Okada, Kiyofumi Gyo, Taro Takagi, Takashi Fujiwara, Hirotaka Takahashi, Nobuhiro Hakuba & Naohito Hato. (2014) Air-bone gap in ears with a well-repaired tympanic membrane after Type III and Type IV tympanoplasty. Auris Nasus Larynx 41:2, pages 153-159.
Crossref
A.O. Gostian, D. Pazen, J.C. Luers, K.B. Huttenbrink & D. Beutner. (2013) Titanium ball joint total ossicular replacement prosthesis – Experimental evaluation and midterm clinical results. Hearing Research 301, pages 100-104.
Crossref
Yoav Hahn & Dennis I. Bojrab. (2013) Outcomes following Ossicular Chain Reconstruction with Composite Prostheses: Hydroxyapatite-Polyethylene vs. Hydroxyapatite-Titanium. Ear, Nose & Throat Journal 92:6, pages 250-260.
Crossref
Saumil N. Merchant & John J. Rosowski. 2013. The Middle Ear. The Middle Ear 253 272 .
Hiroyuki Yamada & Richard L. Goode. (2010) A Self-Adjusting Ossicular Prosthesis Containing Polyurethane Sponge. Otology & Neurotology 31:9, pages 1404-1408.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.