798
Views
143
CrossRef citations to date
0
Altmetric
ORIGINAL ARTICLE

Cochleostomy site: Implications for electrode placement and hearing preservation

, FACS , FRACS, , &
Pages 870-876 | Received 02 Nov 2004, Published online: 08 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (18)

Nadine Schart-Morén, Elsa Erixon, Hao Li & Helge Rask-Andersen. (2020) Cochlear implantation and residual hearing preservation long-term follow-up of the first consecutively operated patients using the round window approach in Uppsala, Sweden. Cochlear Implants International 21:5, pages 246-259.
Read now
Thomas G. Landry, Guy Earle, Jeremy A. Brown & Manohar L. Bance. (2018) Real-time intracochlear imaging of automated cochlear implant insertions in whole decalcified cadaver cochleas using ultrasound. Cochlear Implants International 19:5, pages 255-267.
Read now
Xintai Fan, Ming Xia, Zhe Wang, Hui Zhang, Chengcheng Liu, Na Wang, Lingxiao Hou, Chen Li & Anting Xu. (2018) Comparison of electrode position between round window and cochleostomy inserting approaches among young children: a cone-beam computed tomography study. Acta Oto-Laryngologica 138:9, pages 815-821.
Read now
Joshua A. Tillinger, Chhavi Gupta, Kadri Ila, Jamal Ahmed, Jeenu Mittal, Thomas R. Van De Water & Adrien A. Eshraghi. (2018) l-N-acetylcysteine protects outer hair cells against TNFα initiated ototoxicity in vitro. Acta Oto-Laryngologica 138:8, pages 676-684.
Read now
Bridget Copson, Sudanthi Wijewickrema, Yun Zhou, Patorn Piromchai, Robert Briggs, James Bailey, Gregor Kennedy & Stephen O'Leary. (2017) Supporting skill acquisition in cochlear implant surgery through virtual reality simulation. Cochlear Implants International 18:2, pages 89-96.
Read now
C J Coulson, M Zoka Assadi, R P Taylor, X Du, P N Brett, A P Reid & D W Proops. (2013) A smart micro-drill for cochleostomy formation: A comparison of cochlear disturbances with manual drilling and a human trial. Cochlear Implants International 14:2, pages 98-106.
Read now
Stephen E.J. Connor, N. Julian Holland, Andreas Agger, Annabelle C. Leong, Re Ajay Varghese, Dan Jiang & Alec Fitzgerald O'Connor. (2012) Round window electrode insertion potentiates retention in the scala tympani. Acta Oto-Laryngologica 132:9, pages 932-937.
Read now
J Addams-Williams, L Munaweera, B Coleman, R Shepherd & S Backhouse. (2011) Cochlear implant electrode insertion: In defence of cochleostomy and factors against the round window membrane approach. Cochlear Implants International 12:sup2, pages S36-S39.
Read now
David R Friedland & Christina Runge. (2011) Hearing preservation surgery: proposal for an evidence-based grading scale. Cochlear Implants International 12:sup1, pages S76-S77.
Read now
Shin-Ichi Usami, Hideaki Moteki, Nobuyoshi Suzuki, Hisakuni Fukuoka, Maiko Miyagawa, Shin-Ya Nishio, Yutaka Takumi, Satoshi Iwasaki & Claude Jolly. (2011) Achievement of hearing preservation in the presence of an electrode covering the residual hearing region. Acta Oto-Laryngologica 131:4, pages 405-412.
Read now
Yisgav Shapira, Adrien A. Eshraghi & Thomas J. Balkany. (2011) The perceived angle of the round window affects electrode insertion trauma in round window insertion – an anatomical study. Acta Oto-Laryngologica 131:3, pages 284-289.
Read now
Luiz Lavinsky, Michelle Lavinsky-Wolff & Joel Lavinsky. (2010) Transcanal Cochleostomy in Cochlear Implantation: Experience with 50 Cases. Cochlear Implants International 11:4, pages 228-232.
Read now
Norio Yamamoto, Shintaro Fujimura, Eriko Ogino, Harukazu Hiraumi, Tatsunori Sakamoto & Juichi Ito. (2010) Management of labyrinthine fistulae in Kyoto University Hospital. Acta Oto-Laryngologica 130:sup563, pages 16-19.
Read now
Thomas R. van de Water, Christine T. Dinh, Richard Vivero, Gia Hoosien, Adrien A. Eshraghi & Thomas J. Balkany. (2010) Mechanisms of hearing loss from trauma and inflammation: otoprotective therapies from the laboratory to the clinic. Acta Oto-Laryngologica 130:3, pages 308-311.
Read now
Andrea Simpson, Hugh J. McDermott, Richard C. Dowell, Catherine Sucher & Robert J.S. Briggs. (2009) Comparison of two frequency-to-electrode maps for acoustic-electric stimulation. International Journal of Audiology 48:2, pages 63-73.
Read now
>Wolfgang Gstoettner, Silke Helbig, Claudia Settevendemie, Uwe Baumann, Jens Wagenblast, Christoph Arnoldner, >Wolfgang Gstoettner, Silke Helbig, Claudia Settevendemie, Uwe Baumann, Jens Wagenblast & Christoph Arnoldner. (2009) A new electrode for residual hearing preservation in cochlear implantation: first clinical results. Acta Oto-Laryngologica 129:4, pages 372-379.
Read now
Ingo Todt, Grit Rademacher, Jan Wagner, Friederike Göpel, Dietmar Basta, Ernst Haider & Arne Ernst. (2009) Evaluation of cochlear implant electrode position after a modified round window insertion by means of a 64-multislice CT. Acta Oto-Laryngologica 129:9, pages 966-970.
Read now
>Hans W. Pau, T. Just, S. Dommerich & D. Behrend. (2007) Temporal bone investigations on landmarks for conventional or endosteal insertion of cochlear electrodes. Acta Oto-Laryngologica 127:9, pages 920-926.
Read now

Articles from other publishers (125)

Ling Ding, Luguang Zhang, Jing Li & Tao Lin. (2023) Electrode−Modiolus Distance Affects Speech Perception for Lateral Wall Electrodes. Otology & Neurotology 44:10, pages e702-e709.
Crossref
Zubair Hasan, Seraphina Key, Michael Lee & Melville Da Cruz. (2023) Systematic Review of Intracochlear Measurements and Effect on Postoperative Auditory Outcomes after Cochlear Implant Surgery. Otology & Neurotology.
Crossref
Wenxi Gu, Hannah Daoudi, Ghizlene Lahlou, Olivier Sterkers, Evelyne Ferrary, Yann Nguyen, Isabelle Mosnier & Renato Torres. (2023) Auditory outcomes after scala vestibuli array insertion are similar to those after scala tympani insertion 1 year after cochlear implantation. European Archives of Oto-Rhino-Laryngology.
Crossref
Alexander Geerardyn, MengYu ZhuTim Klabbers, Wendy Huinck, Emmanuel Mylanus, Joseph B. NadolJrJr, Nicolas Verhaert & Alicia M. Quesnel. (2023) Human Histology after Structure Preservation Cochlear Implantation via Round Window Insertion. The Laryngoscope.
Crossref
Saad Elzayat, Mahmoud Mandour, Haitham H. Elfarargy, Rasha Lotfy, Valerio Margani, Edoardo Covelli & Maurizio Barbara. (2022) The Impact of the Location of Chorda Tymapni Nerve Origin on the Round Window Accessibility During Pediatric Cochlear Implantation: A Radioclinical Assessment. Otology & Neurotology 43:8, pages e829-e834.
Crossref
Aniket A. Saoji, Madison K. Graham, Weston J. Adkins, Ashley M. Nassiri, Brian A. Neff, Matthew L. Carlson & Colin L. W. Driscoll. (2022) Relationship Between Intraoperative Electrocochleography Responses and Immediate Postoperative Bone Conduction Thresholds in Cochlear Implantation. Otology & Neurotology 43:8, pages e880-e887.
Crossref
Vardhan S Avasarala, Sanjay K Jinka & Anita Jeyakumar. (2022) Complications of Cochleostomy Versus Round Window Surgical Approaches: A Systematic Review and Meta-Analysis. Cureus.
Crossref
Bridget Copson, Sudanthi Wijewickrema, Xingjun Ma, Yun Zhou, Jean-Marc Gerard & Stephen O’Leary. (2021) Surgical approach to the facial recess influences the acceptable trajectory of cochlear implantation electrodes. European Archives of Oto-Rhino-Laryngology 279:1, pages 137-147.
Crossref
William Crohan & Gunesh P. Rajan. 2022. Cochlear Implants. Cochlear Implants 363 385 .
Murat Koc, Abdullah Dalgic & Mehmet Ziya Ozuer. (2021) The Effects of Round Window Membrane Injury and the Use of a Model Electrode Application on Hearing in Rats. Ear, Nose & Throat Journal, pages 014556132199018.
Crossref
Arman Danielian, Gail Ishiyama, Ivan A. Lopez & Akira Ishiyama. (2021) Predictors of Fibrotic and Bone Tissue Formation With 3-D Reconstructions of Post-Implantation Human Temporal Bones. Otology & Neurotology Publish Ahead of Print.
Crossref
P. Reynard, E. Ionescu, C.A. Joly, A. Ltaief-Boudrigua, A. Coudert & H. Thai-Van. (2021) Vestibular impairment in cochlear implanted children presenting enlarged vestibular aqueduct and enlarged endolymphatic sac. International Journal of Pediatric Otorhinolaryngology 141, pages 110557.
Crossref
Michael B. Pringle & Katarzyna M. Konieczny. (2020) Anatomy of the Round Window Region With Relation to Selection of Entry Site Into the Scala Tympani. The Laryngoscope 131:2.
Crossref
Joaquin E. Jimenez, Nandini Govil, Amber D. Shaffer, Jessica C. Ledonne & David H. Chi. (2021) Hearing preservation with a slim modiolar cochlear implant in a pediatric cohort. International Journal of Pediatric Otorhinolaryngology 140, pages 110479.
Crossref
Howard W. Francis, Carlton J. Zdanski, Ivette Cejas & Laurie Eisenberg. 2021. Cummings Pediatric Otolaryngology. Cummings Pediatric Otolaryngology 236 248 .
Mozafar Sarafraz, Mahsa Heidari, Arash Bayat, Mohammad Ghasem Hanafi, Ali Fahimi, Maryam Farasat, Nader Saki & Javad Molaei. (2020) Role of HRCT imaging in predicting the visibility of Round window (RW) on patients underwent cochlear implant surgery. Clinical Epidemiology and Global Health 8:2, pages 432-436.
Crossref
Floris Heutink, Berit M. Verbist, Lucas H. M. Mens, Wendy J. Huinck & Emmanuel A. M. Mylanus. (2019) The evaluation of a slim perimodiolar electrode: surgical technique in relation to intracochlear position and cochlear implant outcomes. European Archives of Oto-Rhino-Laryngology 277:2, pages 343-350.
Crossref
Aniket A. Saoji, Neil S. Patel, Matthew L. Carlson, Brian A. Neff, Kanthaiah Koka, Venkata S. Aditya Tarigoppula & Colin L. W. Driscoll. (2019) Multi-frequency Electrocochleography Measurements can be Used to Monitor and Optimize Electrode Placement During Cochlear Implant Surgery. Otology & Neurotology 40:10, pages 1287-1291.
Crossref
Megan J. Foggia, Rene Vielman Quevedo & Marlan R. Hansen. (2019) Intracochlear fibrosis and the foreign body response to cochlear implant biomaterials. Laryngoscope Investigative Otolaryngology 4:6, pages 678-683.
Crossref
Anastasiya Starovoyt, Tristan Putzeys, Jan Wouters & Nicolas Verhaert. (2019) High-resolution Imaging of the Human Cochlea through the Round Window by means of Optical Coherence Tomography. Scientific Reports 9:1.
Crossref
R Sharma, R Meher, J C Passey, J Kumar, A Gupta & S Kharbanda. (2019) Comparative evaluation of round window niche accessibility pre-operatively on high-resolution computed tomography of the temporal bone with intra-operative findings. The Journal of Laryngology & Otology 133:7, pages 575-579.
Crossref
Jianqing Chen, Yingwei Wu, Jun Shi, Huan Jia, Zhaoyan Wang, Zhihua Zhang & Hao Wu. (2019) Predictors of round window membrane visibility in pediatric cochlear implant surgery using temporal bone HRCT: A retrospective study. International Journal of Pediatric Otorhinolaryngology 121, pages 150-153.
Crossref
Katherine Gautschi-Mills, Katijah Khoza-Shangase & Dhanashree Pillay. (2019) Preservation of residual hearing after cochlear implant surgery: an exploration of residual hearing function in a group of recipients at cochlear implant units. Brazilian Journal of Otorhinolaryngology 85:3, pages 310-318.
Crossref
Rasim Yilmazer, Robert C. Gerring, Charif Sidani, Amit Wolfovitz, Simon I. Angeli & Fred F. Telischi. (2018) The Feasibility of Retrofacial Approach for Cochlear Implantation. Otology & Neurotology 39:7, pages e550-e556.
Crossref
S Sharma, M Grover, S N Singh, T Kataria & R S Lakhawat. (2018) Cochlear orientation: pre-operative evaluation and intra-operative significance. The Journal of Laryngology & Otology 132:06, pages 540-543.
Crossref
Leise Elisabeth Hviid Korsager, Jesper Hvass Schmidt, Christian Faber & Jens Højberg Wanscher. (2018) Vestibular Outcome After Cochlear Implantation Is Not Related to Surgical Technique: A Double Blinded, Randomized Clinical Trial of Round Window Approach Versus Cochleostomy. Otology & Neurotology 39:3, pages 306-312.
Crossref
Lisandro Leon, Frank M. Warren & Jake J. Abbott. (2018) An In-Vitro Insertion-Force Study of Magnetically Guided Lateral-Wall Cochlear-Implant Electrode Arrays. Otology & Neurotology 39:2, pages e63-e73.
Crossref
Matthew L. Carlson, Brendan P. O’Connell, Christine M. Lohse, Colin L. Driscoll & Alex D. Sweeney. (2018) Survey of the American Neurotology Society on Cochlear Implantation: Part 2, Surgical and Device-Related Practice Patterns. Otology & Neurotology 39:1, pages e20-e27.
Crossref
Naresh Panda. (2017) Evaluation of Round Window Accessibility for Electrode Insertion: Validation Study from two Centers. Journal of Otolaryngology-ENT Research 8:5.
Crossref
Yasser A. Fouad, Ahmad Shaker Elaassar, Mohammad Waheed El-anwar, Ebrahim Sabir, Ahmad Abdelhamid & Mai Ghonimy. (2017) Role of Multislice CT Imaging in Predicting the Visibility of the Round Window in Pediatric Cochlear Implantation. Otology & Neurotology 38:8, pages 1097-1103.
Crossref
Kapil Sikka, Arvind Kairo, Chirom Amit Singh, T. S. Roy, Sanjeev Lalwani, Rakesh Kumar, Alok Thakar & Suresh C. Sharma. (2017) An Evaluation of the Surgical Trauma to Intracochlear Structures After Insertion of Cochlear Implant Electrode Arrays: A Comparison by Round Window and Antero-Inferior Cochleostomy Techniques. Indian Journal of Otolaryngology and Head & Neck Surgery 69:3, pages 375-379.
Crossref
Ihab Nada, Ahmed Nabil Abdelhamid & Ahmed Negm. (2017) The utilization of round window membrane surface tension in facilitating slim electrodes insertion during cochlear implantation. European Archives of Oto-Rhino-Laryngology 274:9, pages 3327-3334.
Crossref
Jonathon Lo, Phillip Sale, Sudanthi Wijewickrema, Luke Campbell, Hayden Eastwood & Stephen John O’leary. (2017) Defining the Hook Region Anatomy of the Guinea Pig Cochlea for Modeling of Inner Ear Surgery. Otology & Neurotology 38:6, pages e179-e187.
Crossref
Xingjun Ma, Sudanthi Wijewickrema, Yun Zhou, Bridget Copson, James Bailey, Gregor Kennedy & Stephen O'Leary. (2017) Simulation for Training Cochlear Implant Electrode Insertion. Simulation for Training Cochlear Implant Electrode Insertion.
Pooneh R. TabriziHongqiang SangHadi F. TalariDiego PreciadoReza MonfarediBrian ReillySreekanth ArikatlaAndinet EnquobahrieKevin Cleary. Temporal bone dissection simulator for training pediatric otolaryngology surgeons. Temporal bone dissection simulator for training pediatric otolaryngology surgeons.
Yu. K. Yanov, V. E. Kuzovkov, A. S. Lilenko, I. V. Kostevich, S. B. Sugarova & A. Sh. Amonov. (2017) Topographic anatomy of the hook region and its significance for the choice of the surgical technique for the cochlear implantation. Vestnik otorinolaringologii 82:3, pages 4.
Crossref
Jorge de Abajo, Raquel Manrique-Huarte, Ignacio Sanhueza, Laura Alvarez-Gómez, Cristina Zulueta-Santos, Diego Calavia, Fernando Ramírez & Manuel Manrique. (2017) Effects of Implantation and Reimplantation of Cochlear Implant Electrodes in an In Vivo Animal Experimental Model (Macaca fascicularis). Ear & Hearing 38:1, pages e57-e68.
Crossref
Conor Kelly & Lina A. J. Reiss. (2017) Hearing Preservation Cochlear Implants: A Review of Potential Mechanisms of Hearing Loss After Implantation. Perspectives of the ASHA Special Interest Groups 2:6, pages 54-63.
Crossref
Daniel Thomas Ginat, Gul Moonis, Suresh K. Mukherji & Michael B. Gluth. 2017. Atlas of Postsurgical Neuroradiology. Atlas of Postsurgical Neuroradiology 351 419 .
Yusu Ni, Peidong Dai, Chunfu Dai & Huawei Li. (2017) Cochlear implant-related three-dimensional characteristics determined by micro-computed tomography reconstruction. Clinical Anatomy 30:1, pages 39-43.
Crossref
Anita S. Deshpande & N. Wendell Todd. (2016) Implanting straight into cochlea risks the facial nerve: a Cartesian coordinate study. Surgical and Radiologic Anatomy 38:10, pages 1153-1159.
Crossref
Brendan P. O'ConnellJacob B. HunterGeorge B. Wanna. (2016) The importance of electrode location in cochlear implantation. Laryngoscope Investigative Otolaryngology 1:6, pages 169-174.
Crossref
M J Polonenko, S L Cushing, K A Gordon, B Allemang, S Jewell & B C Papsin. (2016) Stimulation parameters differ between current anti-modiolar and peri-modiolar electrode arrays implanted within the same child. The Journal of Laryngology & Otology 130:11, pages 1007-1021.
Crossref
Leopoldo Cordero. (2016) IMPLANTE COCLEAR Y AUDICIÓN RESIDUAL. Revista Médica Clínica Las Condes 27:6, pages 808-811.
Crossref
Soha Hamada, Abir Omara, Ihab K. Sefein & Amr Younes. (2016) The impact of electrode type on intraoperative and postoperative telemetry measures in cochlear implant using different surgical technique. The Egyptian Journal of Otolaryngology 32:4, pages 264-270.
Crossref
Clair Vandersteen, Thomas Demarcy, Coralie Roger, Eric Fontas, Charles Raffaelli, Nicholas Ayache, Hervé Delingette & Nicolas Guevara. (2015) Impact of the surgical experience on cochleostomy location: a comparative temporal bone study between endaural and posterior tympanotomy approaches for cochlear implantation. European Archives of Oto-Rhino-Laryngology 273:9, pages 2355-2361.
Crossref
Kevin Cleary. (2016) Medical robotics for pediatric applications shoulder arthrography, ankle rehabilitation, and temporal bone surgery. Medical robotics for pediatric applications shoulder arthrography, ankle rehabilitation, and temporal bone surgery.
B. Devroede, I. Pauwels, S.-D. Le Bon, J. Monstrey & A.-L. Mansbach. (2016) Interest of vestibular evaluation in sequentially implanted children: Preliminary results. European Annals of Otorhinolaryngology, Head and Neck Diseases 133, pages S7-S11.
Crossref
Feng Yang, Yang Liu, Jianjun Sun, Jinrang Li & Rendong Song. (2015) Congenital malformation of the oval window: experience of radiologic diagnosis and surgical technique. European Archives of Oto-Rhino-Laryngology 273:3, pages 593-600.
Crossref
Yang Liu & Feng Yang. (2015) Scala tympani drill-out technique for oval window atresia with malformed facial nerve: A report of three cases. Journal of Otology 10:4, pages 154-158.
Crossref
Marian Poley, Emma Overmyer, Patricia Craun, Meredith Holcomb, Brian Reilly, David White & Diego Preciado. (2015) Does pediatric cochlear implant insertion technique affect intraoperative neural response telemetry thresholds?. International Journal of Pediatric Otorhinolaryngology 79:9, pages 1404-1407.
Crossref
Ya Liu, Claude Jolly, Susanne Braun, Thomas Janssen, Elias Scherer, Jochen Steinhoff, Harald Ebenhoch, Andrea Lohner, Thomas Stark & Jan Kiefer. (2015) Effects of a dexamethasone-releasing implant on cochleae: A functional, morphological and pharmacokinetic study. Hearing Research 327, pages 89-101.
Crossref
Hongzheng Zhang, Gemaine Stark & Lina Reiss. (2015) Changes in Gene Expression and Hearing Thresholds After Cochlear Implantation. Otology & Neurotology 36:7, pages 1157-1165.
Crossref
Jennifer C. Alyono, C. Eduardo Corrales, Markus E. Huth, Nikolas H. Blevins & Anthony J. Ricci. (2015) Development and Characterization of Chemical Cochleostomy in the Guinea Pig. Otolaryngology–Head and Neck Surgery 152:6, pages 1113-1118.
Crossref
Hayo Andrés Breinbauer & Mark Praetorius. (2015) Variability of an Ideal Insertion Vector for Cochlear Implantation. Otology & Neurotology 36:4, pages 610-617.
Crossref
Ling Zhou, David R. Friedmann, Claudiu Treaba, Robert Peng & J. Thomas RolandJr.Jr.. (2015) Does cochleostomy location influence electrode trajectory and intracochlear trauma?. The Laryngoscope 125:4, pages 966-971.
Crossref
Luke Campbell, Arielle Kaicer, Robert Briggs & Stephen O’Leary. (2015) Cochlear Response Telemetry. Otology & Neurotology 36:3, pages 399-405.
Crossref
Esperanza Bas, Christine T. Dinh, Rosemary Ojo, Adrien A. Eshraghi & Thomas R. Van De Water. 2015. Free Radicals in ENT Pathology. Free Radicals in ENT Pathology 395 421 .
Lisandro Leon, Matt S. Cavilla, Michael B. Doran, Frank M. Warren & Jake J. Abbott. (2014) Scala-Tympani Phantom With Cochleostomy and Round-Window Openings for Cochlear-Implant Insertion Experiments. Journal of Medical Devices 8:4.
Crossref
Charissa N. Kahue, Alex D. Sweeney, Matthew L. Carlson & David S. Haynes. (2014) Vaccination recommendations and risk of meningitis following cochlear implantation. Current Opinion in Otolaryngology & Head and Neck Surgery 22:5, pages 359-366.
Crossref
Chiemi Tanaka, Anh Nguyen-Huynh, Katherine Loera, Gemaine Stark & Lina Reiss. (2014) Factors associated with hearing loss in a normal-hearing guinea pig model of hybrid cochlear implants. Hearing Research 316, pages 82-93.
Crossref
Joseph Y. Young, Maura E. Ryan & Nancy M. Young. (2014) Preoperative Imaging of Sensorineural Hearing Loss in Pediatric Candidates for Cochlear Implantation. RadioGraphics 34:5, pages E133-E149.
Crossref
Sushrut Kale, Vanessa M. Cervantes, Mailing R. Wu, Dominic V. Pisano, Nakul Sheth & Elizabeth S. Olson. (2014) A novel perfusion-based method for cochlear implant electrode insertion. Hearing Research 314, pages 33-41.
Crossref
Claire Iseli, Oliver F. Adunka & Craig A. Buchman. (2014) Scala tympani cochleostomy survey: A follow‐up study. The Laryngoscope 124:8, pages 1928-1931.
Crossref
Sidharth V Puram & Daniel J Lee. 2005. Encyclopedia of Life Sciences. Encyclopedia of Life Sciences.
J. T. F. Postelmans, R. J. Stokroos, E. van Spronsen, W. Grolman, R. A. Tange, M. J. Maré & Wouter Albert Dreschler. (2013) Comparison of two cochlear implantation techniques and their effects on the preservation of residual hearing. Is the surgical approach of any importance?. European Archives of Oto-Rhino-Laryngology 271:5, pages 997-1005.
Crossref
Rebecca L. Turok, Robert F. Labadie, George B. Wanna, Benoit M. Dawant & Jack H. Noble. Cochlear implant simulator for surgical technique analysis. Cochlear implant simulator for surgical technique analysis.
Henryk Skarżyński & Piotr Skarżyński. (2020) New strategy of partial deafness treatment – 18 years of experience. Nowa Audiofonologia 3:5, pages 9-16.
Crossref
Francesca Atturo, Maurizio Barbara & Helge Rask-Andersen. (2014) On the Anatomy of the ‘Hook' Region of the Human Cochlea and How It Relates to Cochlear Implantation. Audiology and Neurotology 19:6, pages 378-385.
Crossref
Wilhelm Wimmer, Frederic Venail, Tom Williamson, Mohamed Akkari, Nicolas Gerber, Stefan Weber, Marco Caversaccio, Alain Uziel & Brett Bell. (2014) Semiautomatic Cochleostomy Target and Insertion Trajectory Planning for Minimally Invasive Cochlear Implantation. BioMed Research International 2014, pages 1-8.
Crossref
Priscila Carvalho Miranda, André Luiz Lopes Sampaio, Rafaela Aquino Fernandes Lopes, Alessandra Ramos Venosa & Carlos Augusto Costa Pires de Oliveira. (2014) Hearing Preservation in Cochlear Implant Surgery. International Journal of Otolaryngology 2014, pages 1-6.
Crossref
Eun-Ju Jeon, Beomcho Jun, Ji-Nam Song, Ju-Eun Kim, Dong Hee Lee & Ki-Hong Chang. (2013) Surgical and radiologic anatomy of a cochleostomy produced via posterior tympanotomy for cochlear implantation based on three-dimensional reconstructed temporal bone CT images. Surgical and Radiologic Anatomy 35:6, pages 471-475.
Crossref
Annabelle C. Leong, Dan Jiang, Andreas Agger & Alec Fitzgerald-O’Connor. (2012) Evaluation of round window accessibility to cochlear implant insertion. European Archives of Oto-Rhino-Laryngology 270:4, pages 1237-1242.
Crossref
Ashish Alappatt, Vijaya Paramasivan, Senthil Arumugam, Raghunandhan Sampath & Mohan Kameswaran. (2013) EFFICACY AND OUTCOMES OF HEARING PRESERVATION TECHNIQUE IN COCHLEAR IMPLANTEES WITH RESIDUAL HEARING: EXPERIENCE IN INDIAN PATIENTS. Journal of Hearing Science 3:3, pages 52-59.
Crossref
E.B. King, J.J. Hartsock, S.J. O'Leary & A.N. Salt. (2013) Influence of Cochleostomy and Cochlear Implant Insertion on Drug Gradients following Intratympanic Application in Guinea Pigs. Audiology and Neurotology 18:5, pages 307-316.
Crossref
Guilherme Machado de Carvalho, Alexandre C. Guimaraes, Alexandre S. M. Duarte, Eder B. Muranaka, Marcelo N. Soki, Renata S. Zanotello Martins, Walter A. Bianchini, Jorge R. Paschoal & Arthur M. Castilho. (2013) Hearing Preservation after Cochlear Implantation: UNICAMP Outcomes. International Journal of Otolaryngology 2013, pages 1-8.
Crossref
David A. Gudis, Michelle Montes, Douglas C. Bigelow & Michael J. Ruckenstein. (2012) The Round Window. Otology & Neurotology 33:9, pages 1497-1501.
Crossref
Esperanza Bas, Christine T. Dinh, Carolyn Garnham, Marek Polak & Thomas R. Van de Water. (2012) Conservation of hearing and protection of hair cells in cochlear implant patients' with residual hearing. The Anatomical Record: Advances in Integrative Anatomy and Evolutionary Biology 295:11, pages 1909-1927.
Crossref
Daren Gibson, Michael B. Gluth, Andy Whyte & Marcus D. Atlas. (2011) Rotation of the osseous spiral lamina from the hook region along the basal turn of the cochlea: results of a magnetic resonance image anatomical study using high-resolution DRIVE sequences. Surgical and Radiologic Anatomy 34:8, pages 781-785.
Crossref
. (2012) Nowa strategia leczenia częściowej głuchoty – 10 lat doświadczeń. Nowa Audiofonologia 1:3, pages 11-17.
Crossref
Marco Mandalà, Liliana Colletti, Giovanni Tonoli & Vittorio Colletti. (2012) Electrocochleography during Cochlear Implantation for Hearing Preservation. Otolaryngology–Head and Neck Surgery 146:5, pages 774-781.
Crossref
Maura K. Cosetti, Scott H. Troob, Jonathan M. Latzman, William H. Shapiro, John Thomas Roland & Susan B. Waltzman. (2012) An Evidence-Based Algorithm for Intraoperative Monitoring During Cochlear Implantation. Otology & Neurotology 33:2, pages 169-176.
Crossref
Sarah E. Mowry, Erika Woodson & Bruce J. Gantz. (2012) New Frontiers in Cochlear Implantation: Acoustic Plus Electric Hearing, Hearing Preservation, and More. Otolaryngologic Clinics of North America 45:1, pages 187-203.
Crossref
Selena E. Heman-Ackah, J. Thomas RolandJr.Jr., David S. Haynes & Susan B. Waltzman. (2012) Pediatric Cochlear Implantation: Candidacy Evaluation, Medical and Surgical Considerations, and Expanding Criteria. Otolaryngologic Clinics of North America 45:1, pages 41-67.
Crossref
Henryk Skarzynski. (2012) TEN YEARS EXPERIENCE WITH A NEW STRATEGY OF PARTIAL DEAFNESS TREATMENT. Journal of Hearing Science 2:2, pages 11-18.
Crossref
Daniel Thomas Ginat & Per-Lennart A. WestessonDaniel Thomas Ginat, Gul Moonis & Suresh K. Mukherji. 2012. Atlas of Postsurgical Neuroradiology. Atlas of Postsurgical Neuroradiology 287 340 .
E. B. King, A. N. Salt, H. T. Eastwood & S. J. O’Leary. (2011) Direct Entry of Gadolinium into the Vestibule Following Intratympanic Applications in Guinea Pigs and the Influence of Cochlear Implantation. Journal of the Association for Research in Otolaryngology 12:6, pages 741-751.
Crossref
Rodrigo Martinez-Monedero, John K. Niparko & Nafi Aygun. (2011) Cochlear Coiling Pattern and Orientation Differences in Cochlear Implant Candidates. Otology & Neurotology 32:7, pages 1086-1093.
Crossref
Patrick Lecerf, David Bakhos, Jean-Philippe Cottier, Emmanuel Lescanne, Jean Paul Trijolet & Alain Robier. (2011) Midmodiolar Reconstruction as a Valuable Tool to Determine the Exact Position of the Cochlear Implant Electrode Array. Otology & Neurotology 32:7, pages 1075-1081.
Crossref
Colin L.W. Driscoll, Matthew L. Carlson, Anthony F. Fama & John I. Lane. (2011) Evaluation of the hybrid‐L24® electrode using microcomputed tomography. The Laryngoscope 121:7, pages 1508-1516.
Crossref
A. Aschendorff, T. Klenzner, S. Arndt, R. Beck, C. Schild, L. Röddiger, W. Maier & R. Laszig. (2011) Insertionsergebnisse von Contour™- und Contour-Advance™-ElektrodenInsertion results for Contour™ and Contour Advance™ electrodes. HNO 59:5, pages 448-452.
Crossref
Christopher W. Turner & Bruce J. Gantz. 2012. Auditory Prostheses. Auditory Prostheses 59 84 .
Gregory J. Basura, Oliver F. Adunka & Craig A. Buchman. (2010) Scala tympani cochleostomy for cochlear implantation. Operative Techniques in Otolaryngology-Head and Neck Surgery 21:4, pages 218-222.
Crossref
Benjamin P.C. Wei, Robert K. Shepherd, Roy M. Robins‐Browne, Graeme M. Clark & Stephen J. O'Leary. (2010) Pneumococcal meningitis post‐cochlear implantation: Preventative measures. Otolaryngology–Head and Neck Surgery 143:S5, pages 9-14.
Crossref
Oliver F. Adunka, Stefan Mlot, Thomas A. Suberman, Adam P. Campbell, Joshua Surowitz, Craig A. Buchman & Douglas C. Fitzpatrick. (2010) Intracochlear Recordings of Electrophysiological Parameters Indicating Cochlear Damage. Otology & Neurotology 31:8, pages 1233-1241.
Crossref
Simon K. W. Lloyd, Anand V. Kasbekar, Bruno Kenway, Toby Prevost, Maurice Hockman, Timothy Beale & John Graham. (2010) Developmental Changes in Cochlear Orientation-Implications for Cochlear Implantation. Otology & Neurotology 31:6, pages 902-907.
Crossref
Adam P. Campbell, Thomas A. Suberman, Craig A. Buchman, Douglas C. Fitzpatrick & Oliver F. Adunka. (2010) Flexible cochlear microendoscopy in the gerbil. The Laryngoscope 120:8, pages 1619-1624.
Crossref
Andreas Hussong, Thomas S. Rau, Tobias Ortmaier, Bodo Heimann, Thomas Lenarz & Omid Majdani. (2009) An automated insertion tool for cochlear implants: another step towards atraumatic cochlear implant surgery. International Journal of Computer Assisted Radiology and Surgery 5:2, pages 163-171.
Crossref
Thomas S. Rau, Andreas Hussong, Martin Leinung, Thomas Lenarz & Omid Majdani. (2009) Automated insertion of preformed cochlear implant electrodes: evaluation of curling behaviour and insertion forces on an artificial cochlear model. International Journal of Computer Assisted Radiology and Surgery 5:2, pages 173-181.
Crossref
Andrew J. Fishman, Laura E. Moreno, Arnold Rivera & Claus‐Peter Richter. (2010) CO 2 laser fiber soft cochleostomy: Development of a technique using human temporal bones and a guinea pig model . Lasers in Surgery and Medicine 42:3, pages 245-256.
Crossref
Xenia Meshik, Timothy A. Holden, Richard A. Chole & Timothy E. Hullar. (2010) Optimal Cochlear Implant Insertion Vectors. Otology & Neurotology 31:1, pages 58-63.
Crossref
Hayden Eastwood, Darren Pinder, David James, Andrew Chang, Stuart Galloway, Rachael Richardson & Stephen O’Leary. (2010) Permanent and transient effects of locally delivered n-acetyl cysteine in a guinea pig model of cochlear implantation. Hearing Research 259:1-2, pages 24-30.
Crossref
Thomas Klenzner, Chiu Chun Ngan, Felix Bernhard Knapp, Hayo Knoop, Jan Kromeier, Antje Aschendorff, Evangelos Papastathopoulos, Joerg Raczkowsky, Heinz Wörn & Joerg Schipper. (2008) New strategies for high precision surgery of the temporal bone using a robotic approach for cochlear implantation. European Archives of Oto-Rhino-Laryngology 266:7, pages 955-960.
Crossref
David R. FriedlandChristina Runge-Samuelson. (2009) Soft Cochlear Implantation: Rationale for the Surgical Approach. Trends in Amplification 13:2, pages 124-138.
Crossref
Berit M. Verbist, Luca Ferrarini, Jeroen J. Briaire, Andrzej Zarowski, Faiza Admiraal-Behloul, Hans Olofsen, Johan H. C. Reiber & Johan H. M. Frijns. (2009) Anatomic Considerations of Cochlear Morphology and Its Implications for Insertion Trauma in Cochlear Implant Surgery. Otology & Neurotology 30:4, pages 471-477.
Crossref
J.H. Wagner, G. Rademacher, A. Ernst & I. Todt. (2009) Kochleaimplantate im FelsenbeinpräparatCochlear implants in isolated temporal bones. HNO 57:6, pages 575-579.
Crossref
Victor Slavutsky & Luis Nicenboim. (2008) Preliminary results in cochlear implant surgery without antromastoidectomy and with atraumatic electrode insertion: the endomeatal approach. European Archives of Oto-Rhino-Laryngology 266:4, pages 481-488.
Crossref
John S Oghalai, Ross Tonini, Jamie Rasmus, Claudia Emery, Spiros Manolidis, Jeffrey T Vrabec & Joann Haymond. (2009) Intra-operative monitoring of cochlear function during cochlear implantation. Cochlear Implants International 10:1, pages 1-18.
Crossref
Thuy-Anh N. Melvin, Charles C. Della Santina, John P. Carey & Americo A. Migliaccio. (2009) The Effects of Cochlear Implantation on Vestibular Function. Otology & Neurotology 30:1, pages 87-94.
Crossref
C.J. Coulson, A.P. Reid & D.W. Proops. (2008) A cochlear implantation robot in surgical practice. A cochlear implantation robot in surgical practice.
Charles C. Finley, Timothy A. Holden, Laura K. Holden, Bruce R. Whiting, Richard A. Chole, Gail J. Neely, Timothy E. Hullar & Margaret W. Skinner. (2008) Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes. Otology & Neurotology 29:7, pages 920-928.
Crossref
C.J. Coulson, R.P. Taylor, A.P. Reid, M.V. Griffiths, D.W. Proops & P.N. Brett. (2008) An autonomous surgical robot for drilling a cochleostomy: preliminary porcine trial. Clinical Otolaryngology 33:4, pages 343-347.
Crossref
James Lin, Hinrich Staecker & M. Samir Jafri. (2008) Optical Coherence Tomography Imaging of the Inner Ear: A Feasibility Study with Implications for Cochlear Implantation. Annals of Otology, Rhinology & Laryngology 117:5, pages 341-346.
Crossref
Angelo Salami, Massimo Dellepiane, Francesco Mora, Barbara Crippa & Renzo Mora. (2008) Piezosurgery® in the cochleostomy through multiple middle ear approaches. International Journal of Pediatric Otorhinolaryngology 72:5, pages 653-657.
Crossref
Andreas Radeloff, Martin Mack, Mehran Baghi, Wolfgang K. Gstoettner & Oliver F. Adunka. (2008) Variance of Angular Insertion Depths in Free-Fitting and Perimodiolar Cochlear Implant Electrodes. Otology & Neurotology 29:2, pages 131-136.
Crossref
Ingo Todt, Dietmar Basta & Arne Ernst. (2008) Does the surgical approach in cochlear implantation influence the occurrence of postoperative vertigo?. Otolaryngology–Head and Neck Surgery 138:1, pages 8-12.
Crossref
Oliver F. Adunka & Craig A. Buchman. (2007) Scala Tympani Cochleostomy I: Results of a Survey. The Laryngoscope 117:12, pages 2187-2194.
Crossref
Oliver F. Adunka, Andreas Radeloff, Wolfgang K. Gstoettner, Harold C. Pillsbury & Craig A. Buchman. (2007) Scala Tympani Cochleostomy II: Topography and Histology. The Laryngoscope 117:12, pages 2195-2200.
Crossref
Peter M. M. C. Li, Haobing Wang, Clarinda Northrop, Saumil N. Merchant & Joseph B. Nadol. (2007) Anatomy of the Round Window and Hook Region of the Cochlea With Implications for Cochlear Implantation and Other Endocochlear Surgical Procedures. Otology & Neurotology 28:5, pages 641-648.
Crossref
Peter S. Roland, Charles G. Wright & Brandon Isaacson. (2009) Cochlear Implant Electrode Insertion: The Round Window Revisited. The Laryngoscope 117:8, pages 1397-1402.
Crossref
Junping Zhen, Cheng Liu, Shaoyu Wang, Shuwei Liu, Jingzhen He, Jun Wang & Haisong Chen. (2007) The thin sectional anatomy of the temporal bone correlated with multislice spiral CT. Surgical and Radiologic Anatomy 29:5, pages 409-418.
Crossref
Justus Ilgner, W. H. Döring & M. Westhofen. 2007. 4th International Workshop on Wearable and Implantable Body Sensor Networks (BSN 2007). 4th International Workshop on Wearable and Implantable Body Sensor Networks (BSN 2007) 166 170 .
Adrien A Eshraghi. (2006) Prevention of cochlear implant electrode damage. Current Opinion in Otolaryngology & Head & Neck Surgery 14:5, pages 323-328.
Crossref
Oliver Adunka, Patricia Roush, John Grose, Corinne Macpherson & Craig A. Buchman. (2009) Monitoring of Cochlear Function During Cochlear Implantation. The Laryngoscope 116:6, pages 1017-1020.
Crossref
Joseph B. RobersonJrJr. (2005) Cochlear implant surgery: Minimally invasive technique. Operative Techniques in Otolaryngology-Head and Neck Surgery 16:2, pages 74-77.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.