220
Views
68
CrossRef citations to date
0
Altmetric
Research Article

Chronic Electrical Stimulation of the Auditory Nerve using Non-charge-balanced Stimuli

Pages 674-684 | Published online: 08 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

Christie QI Huang, Michael Tykocinski, Dimitra Stathopoulos & Robert Cowan. (2007) Effects of steroids and lubricants on electrical impedance and tissue response following cochlear implantation. Cochlear Implants International 8:3, pages 123-147.
Read now

Articles from other publishers (67)

Kangyu Su, Zhang Qiu & Jian Xu. (2023) A 14-Bit, 12 V-to-100 V Voltage Compliance Electrical Stimulator with Redundant Digital Calibration. Micromachines 14:11, pages 2001.
Crossref
Maxime Feyerick & Wim Dehaene. (2023) Dense, 11 V-Tolerant, Balanced Stimulator IC with Digital Time-Domain Calibration for $< $100 nA Error. IEEE Transactions on Biomedical Circuits and Systems 17:5, pages 1166-1176.
Crossref
Hyunbeen Jeong, Jisung Kim, Jong-Mo Seo & Andrea Neviani. (2022) Neurostimulators for high-resolution artificial retina: ASIC design challenges and solutions. Journal of Neural Engineering.
Crossref
Maxime Feyerick & Wim Dehaene. (2022) An 11 V-tolerant, high-density neurostimulator using time-domain calibration in 65 nm CMOS. An 11 V-tolerant, high-density neurostimulator using time-domain calibration in 65 nm CMOS.
Yuki Hayashida, Seiji Kameda, Yuichi Umehira, Shinnosuke Ishikawa & Tetsuya Yagi. (2022) Multichannel stimulation module as a tool for animal studies on cortical neural prostheses. Frontiers in Medical Technology 4.
Crossref
Leanne Sijgers, Alexander Huber, Sonia Tabibi, Julian Grosse, Christof Roosli, Patrick Boyle, Kanthaiah Koka, Norbert Dillier, Flurin Pfiffner & Adrian Dalbert. (2022) Predicting Cochlear Implant Electrode Placement Using Monopolar, Three-Point and Four-Point Impedance Measurements. IEEE Transactions on Biomedical Engineering 69:8, pages 2533-2544.
Crossref
Trevor L. Bruns, Katherine E. Riojas, Robert F. Labadie & Robert J. Webster III. (2022) Real-Time Localization of Cochlear-Implant Electrode Arrays Using Bipolar Impedance Sensing. IEEE Transactions on Biomedical Engineering 69:2, pages 718-724.
Crossref
Moritz Doering, Jochen Kieninger, Gerald A Urban & Andreas Weltin. (2022) Electrochemical microelectrode degradation monitoring: in situ investigation of platinum corrosion at neutral pH. Journal of Neural Engineering 19:1, pages 016005.
Crossref
David P. Herrmann, Katharina V.A. Kretzer, Sabrina H. Pieper & Andreas Bahmer. (2021) Effects of electrical pulse polarity shape on intra cochlear neural responses in humans: Triphasic pulses with anodic and cathodic second phase. Hearing Research 412, pages 108375.
Crossref
Fatemeh Eshaghi, Esmaeil Najafiaghdam & Hossein Kassiri. (2021) A 24-Channel Neurostimulator IC With Channel-Specific Energy-Efficient Hybrid Preventive-Detective Dynamic-Precision Charge Balancing. IEEE Access 9, pages 95884-95895.
Crossref
Robert K Shepherd, Paul M Carter, Ya Lang Enke, Alex Thompson, Brianna Flynn, Ella P Trang, Ashley N Dalrymple & James B Fallon. (2020) Chronic intracochlear electrical stimulation at high charge densities: reducing platinum dissolution. Journal of Neural Engineering 17:5, pages 056009.
Crossref
Orazio Aiello. (2020) On the DC Offset Current Generated during Biphasic Stimulation: Experimental Study. Electronics 9:8, pages 1198.
Crossref
Patrick J. Boyle. 2020. The Human Auditory System - Basic Features and Updates on Audiological Diagnosis and Therapy. The Human Auditory System - Basic Features and Updates on Audiological Diagnosis and Therapy.
Khaleda Akhter Sathi, Khaleda Akhter Sathi, Md Kamal Hosain, Md. Kamal Hosain, Shuvra Prokash Biswas & Shuvra Prokash Biswas. (2020) Design and Implementation of a Low Power Energy Harvested Head-mountable Deep Brain Stimulation Device. Design and Implementation of a Low Power Energy Harvested Head-mountable Deep Brain Stimulation Device.
Ann E. Todd & David M. Landsberger. (2018) The effect of polarity order and electrode-activation order on loudness in cochlear implant users. The Journal of the Acoustical Society of America 144:2, pages EL112-EL118.
Crossref
Natalie Butz, Armin Taschwer, Sebastian Nessler, Yiannos Manoli & Matthias Kuhl. (2018) A 22 V Compliant 56 <inline-formula> <tex-math notation="LaTeX">${\mu}$ </tex-math> </inline-formula>W Twin-Track Active Charge Balancing Enabling 100% Charge Compensation Even in Monophasic and 36% Amplitude Correction in Biphasic Neural Stimulators. IEEE Journal of Solid-State Circuits 53:8, pages 2298-2310.
Crossref
Robert K Shepherd, Joel Villalobos, Owen Burns & David A X Nayagam. (2018) The development of neural stimulators: a review of preclinical safety and efficacy studies. Journal of Neural Engineering 15:4, pages 041004.
Crossref
Elizabeth A. Kelly, Samuel Levine, Kristin E. Gravel, Dianna L. Hart & Tina Huang. (2018) Utilization of Nerve Integrity Monitor for Promontory Stimulation Testing Prior to Cochlear Implant. Otology & Neurotology 39:2, pages e60-e62.
Crossref
G. Luis E. Rueda, Marco Ballini, Nick Van Hellepute & Srinjoy Mitra. (2017) Analysis of passive charge balancing for safe current-mode neural stimulation. Analysis of passive charge balancing for safe current-mode neural stimulation.
. 2016. ANSI/AAMI CI86:2017; Cochlear implant systems: Requirements for safety, functional verification, labeling and reliability reporting. ANSI/AAMI CI86:2017; Cochlear implant systems: Requirements for safety, functional verification, labeling and reliability reporting.
Zhicong Luo & Ming-Dou Ker. (2016) A High-Voltage-Tolerant and Precise Charge-Balanced Neuro-Stimulator in Low Voltage CMOS Process. IEEE Transactions on Biomedical Circuits and Systems 10:6, pages 1087-1099.
Crossref
Sven Grob, Peter A. Tass & Christian Hauptmann. (2016) Capacitive Feedthroughs for Medical Implants. Frontiers in Neuroscience 10.
Crossref
Stuart F. Cogan, David J. Garrett & Rylie A. Green. 2016. Neurobionics: The Biomedical Engineering of Neural Prostheses. Neurobionics: The Biomedical Engineering of Neural Prostheses 55 88 .
Stefan Hahnewald, Anne Tscherter, Emanuele Marconi, Jürg Streit, Hans Rudolf Widmer, Carolyn Garnham, Heval Benav, Marcus Mueller, Hubert Löwenheim, Marta Roccio & Pascal Senn. (2016) Response profiles of murine spiral ganglion neurons on multi-electrode arrays. Journal of Neural Engineering 13:1, pages 016011.
Crossref
Chao Peng, Jinyong Zhang, Xu Zhang & Lei Wang. (2015) A 16-channel electrode driver with precise calibration for electrical neural stimulation. A 16-channel electrode driver with precise calibration for electrical neural stimulation.
Haryong Song, Gyungtae Kim & Hyoungho Ko. (2015) Triple cascode high output impedance current stimulator with dynamic element matching for retinal prostheses. Triple cascode high output impedance current stimulator with dynamic element matching for retinal prostheses.
Adan I. Acosta, Muhammad S. Noor, Zelma H. T. Kiss & Kartikeya Murari. (2015) A lightweight discrete biphasic current stimulator for rodent deep brain stimulation. A lightweight discrete biphasic current stimulator for rodent deep brain stimulation.
Lucas Teixeira, Cesar Rodrigues & César Prior. (2015) Direct Feedback Topology for Reducing Residual Voltage in Functional Electrical Stimulation. Direct Feedback Topology for Reducing Residual Voltage in Functional Electrical Stimulation.
Lucas Teixeira, Cesar Rodrigues & Cesar Prior. (2015) A charge-redistribution based controller for keeping charge balance in neural stimulation. A charge-redistribution based controller for keeping charge balance in neural stimulation.
Sudip Nag, Dinesh Sharma & Nitish V. Thakor. 2015. Handbook of Bioelectronics. Handbook of Bioelectronics 365 378 .
Remo A.G.J. Arts, Erwin L.J. George, Andreas Griessner, Clemens Zierhofer & Robert J. Stokroos. (2015) Tinnitus Suppression by Intracochlear Electrical Stimulation in Single-Sided Deafness: A Prospective Clinical Trial - Part I. Audiology and Neurotology 20:5, pages 294-313.
Crossref
Arnaud J. Noreña. (2015) Revisiting the Cochlear and Central Mechanisms of Tinnitus and Therapeutic Approaches. Audiology and Neurotology 20:Suppl. 1, pages 53-59.
Crossref
A. J. Noreña, W. H. A. M. Mulders & D. Robertson. (2015) Suppression of putative tinnitus-related activity by extra-cochlear electrical stimulation. Journal of Neurophysiology 113:1, pages 132-143.
Crossref
Maohua Ren, Jinyong Zhang, Lei Wang & Zhenyu Wang. (2014) A novel biphasic-current-pulse calibration technique for electrical neural stimulation. A novel biphasic-current-pulse calibration technique for electrical neural stimulation.
Manfred Franke, Niloy Bhadra, Narendra Bhadra & Kevin Kilgore. (2014) Direct current contamination of kilohertz frequency alternating current waveforms. Journal of Neuroscience Methods 232, pages 74-83.
Crossref
Mario A. Meza-Cuevas, Dietmar Schroeder & Wolfgang H. Krautschneider. (2014) A scalable 64 channel neurostimulator based on a hybrid architecture of current steering DAC. A scalable 64 channel neurostimulator based on a hybrid architecture of current steering DAC.
R.K. Shepherd, J.B. Fallon & H.J. McDermott. 2014. Comprehensive Biomedical Physics. Comprehensive Biomedical Physics 327 341 .
Manuel Monge, Mayank Raj, Meisam Honarvar Nazari, Han-Chieh Chang, Yu Zhao, James D. Weiland, Mark S. Humayun, Yu-Chong Tai & Azita Emami. (2013) A Fully Intraocular High-Density Self-Calibrating Epiretinal Prosthesis. IEEE Transactions on Biomedical Circuits and Systems 7:6, pages 747-760.
Crossref
Andreas Bahmer & Uwe Baumann. (2013) Effects of electrical pulse polarity shape on intra cochlear neural responses in humans: Triphasic pulses with cathodic second phase. Hearing Research 306, pages 123-130.
Crossref
Jingjing Sun, Yao Chen, Xinyu Chai, Qiushi Ren & Liming Li. (2013) Penetrating electrode stimulation of the rabbit optic nerve: parameters and effects on evoked cortical potentials. Graefe's Archive for Clinical and Experimental Ophthalmology 251:11, pages 2545-2554.
Crossref
Cesar Rodrigues, Torsten Lehmann, Kushal Das & Gregg Suaning. (2013) A 2.6V Silicon-on Sapphire CMOS current imbalance sensing circuit for neurostimulation applications. A 2.6V Silicon-on Sapphire CMOS current imbalance sensing circuit for neurostimulation applications.
S. Nag, Xiaofeng Jia, N. Thakor & D. Sharma. (2013) Flexible Charge Balanced Stimulator With 5.6 fC Accuracy for 140 nC Injections. IEEE Transactions on Biomedical Circuits and Systems 7:3, pages 266-275.
Crossref
Anh Tuan Do, Yung Sern Tan, Gordon M. Xiong, Cleo Choong, Zhi Hui Kong & K. S. Yeo. (2013) A current-mode stimulator circuit with two-step charge balancing background calibration. A current-mode stimulator circuit with two-step charge balancing background calibration.
I. Williams & T. G. Constandinou. (2013) An Energy-Efficient, Dynamic Voltage Scaling Neural Stimulator for a Proprioceptive Prosthesis. IEEE Transactions on Biomedical Circuits and Systems 7:2, pages 129-139.
Crossref
Robert Shepherd, Andrew Wise & James Fallon. 2013. Disorders of Peripheral and Central Auditory Processing. Disorders of Peripheral and Central Auditory Processing 315 331 .
Hosung Chun, Yuanyuan Yang & T. Lehmann. (2012) Required matching accuracy of biphasic current pulse in multi-channel current mode bipolar stimulation for safety. Required matching accuracy of biphasic current pulse in multi-channel current mode bipolar stimulation for safety.
Ian Williams & Timothy G. Constandinou. (2012) An energy-efficient, dynamic voltage scaling neural stimulator for a proprioceptive prosthesis. An energy-efficient, dynamic voltage scaling neural stimulator for a proprioceptive prosthesis.
Antoine Nonclercq, Laurent Lonys, Anne Vanhoestenberghe, Andreas Demosthenous & Nick Donaldson. (2012) Safety of multi-channel stimulation implants: a single blocking capacitor per channel is not sufficient after single-fault failure. Medical & Biological Engineering & Computing 50:4, pages 403-410.
Crossref
Marek Zadrożniak, Marcin Szymański, Henryk Siwiec & Tomasz Broda. (2011) Zmiany impedancji elektrod u użytkowników implantów ślimakowych. Otolaryngologia Polska 65:3, pages 214-217.
Crossref
Arnaud Jean Noreña. (2011) An integrative model of tinnitus based on a central gain controlling neural sensitivity. Neuroscience & Biobehavioral Reviews 35:5, pages 1089-1109.
Crossref
Hosung Chun, Torsten Lehmann & Yuanyuan Yang. (2010) Implantable stimulator for bipolar stimulation without charge balancing circuits. Implantable stimulator for bipolar stimulation without charge balancing circuits.
Shufeng Li, Huawei Li & Zhengmin Wang. (2010) Orientation of spiral ganglion neurite extension in electrical fields of charge-balanced biphasic pulses and direct current in vitro. Hearing Research 267:1-2, pages 111-118.
Crossref
Rahul Sarpeshkar. 2010. Ultra Low Power Bioelectronics. Ultra Low Power Bioelectronics 531 578 .
Olivier Macherey, Astrid van Wieringen, Robert P. Carlyon, Ingeborg Dhooge & Jan Wouters. (2010) Forward-masking patterns produced by symmetric and asymmetric pulse shapes in electric hearing. The Journal of the Acoustical Society of America 127:1, pages 326-338.
Crossref
Song Guo & Hoi Lee. (2009) Biphasic-current-pulse self-calibration techniques for monopolar current stimulation. Biphasic-current-pulse self-calibration techniques for monopolar current stimulation.
IVAN OSORIO & M. G. FREI. (2011) SEIZURE ABATEMENT WITH SINGLE DC PULSES: IS PHASE RESETTING AT PLAY?. International Journal of Neural Systems 19:03, pages 149-156.
Crossref
Ethan D Cohen. (2009) Effects of high-level pulse train stimulation on retinal function. Journal of Neural Engineering 6:3, pages 035005.
Crossref
Thomas Jochum, Timothy Denison & Patrick Wolf. (2009) Integrated circuit amplifiers for multi-electrode intracortical recording. Journal of Neural Engineering 6:1, pages 012001.
Crossref
Kensall D. Wise, Pamela T. Bhatti, Jianbai Wang & Craig R. Friedrich. (2008) High-density cochlear implants with position sensing and control. Hearing Research 242:1-2, pages 22-30.
Crossref
Astrid van Wieringen, Olivier Macherey, Robert P. Carlyon, John M. Deeks & Jan Wouters. (2008) Alternative pulse shapes in electrical hearing. Hearing Research 242:1-2, pages 154-163.
Crossref
Ji-Jon Sit & Rahul Sarpeshkar. (2007) A Low-Power Blocking-Capacitor-Free Charge-Balanced Electrode-Stimulator Chip With Less Than 6 nA DC Error for 1-mA Full-Scale Stimulation. IEEE Transactions on Biomedical Circuits and Systems 1:3, pages 172-183.
Crossref
Pamela T. Bhatti & Kensall D. Wise. (2006) A 32-Site 4-Channel High-Density Electrode Array for a Cochlear Prosthesis. IEEE Journal of Solid-State Circuits 41:12, pages 2965-2973.
Crossref
Olivier Macherey, Astrid van Wieringen, Robert P. Carlyon, John M. Deeks & Jan Wouters. (2006) Asymmetric Pulses in Cochlear Implants: Effects of Pulse Shape, Polarity, and Rate. Journal of the Association for Research in Otolaryngology 7:3, pages 253-266.
Crossref
Robert P. Carlyon, Astrid van Wieringen, John M. Deeks, Christopher J. Long, Johannes Lyzenga & Jan Wouters. (2005) Effect of inter-phase gap on the sensitivity of cochlear implant users to electrical stimulation. Hearing Research 205:1-2, pages 210-224.
Crossref
Blake Murphy, Charles Krieger & Joaquin-Andres Hoffer. (2004) Chronically implanted epineural electrodes for repeated assessment of nerve conduction velocity and compound action potential amplitude in rodents. Journal of Neuroscience Methods 132:1, pages 25-33.
Crossref
Michael Tykocinski, Yvonne Duan, Bruce Tabor & Robert S Cowan. (2001) Chronic electrical stimulation of the auditory nerve using high surface area (HiQ) platinum electrodes. Hearing Research 159:1-2, pages 53-68.
Crossref
Christie Q Huang & Robert K Shepherd. (2000) Reduction in excitability of the auditory nerve following electrical stimulation at high stimulus rates: V. Effects of electrode surface area. Hearing Research 146:1-2, pages 57-71.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.