419
Views
120
CrossRef citations to date
0
Altmetric
Research Article

Increased Blood Cobalt and Chromium After Total Hip Replacement

, , , , &
Pages 839-844 | Published online: 22 Dec 1999

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (9)

J. B. Leikin, H. C. Karydes, P. M. Whiteley, B. K. Wills, K. L. Cumpston & J. J. Jacobs. (2013) Outpatient toxicology clinic experience of patients with hip implants. Clinical Toxicology 51:4, pages 230-236.
Read now
JS Hayes & RG Richards. (2010) The use of titanium and stainless steel in fracture fixation. Expert Review of Medical Devices 7:6, pages 843-853.
Read now
Jacob Pontoppidan Thyssen, Stig Storgaard Jakobsen, Kåre Engkilde, Jeanne Duus Johansen, Kjeld Søballe & Torkil Menné. (2009) The association between metal allergy, total hip arthroplasty, and revision. Acta Orthopaedica 80:6, pages 646-652.
Read now
X. Y. Li, N. Habibi, T. Bell & H. Dong. (2007) Microstructural characterisation of a plasma carburised low carbon Co–Cr alloy. Surface Engineering 23:1, pages 45-51.
Read now
Wolf-Christoph Witzleb, Joerg Ziegler, Frank Krummenauer, Volker Neumeister & Klaus-Peter Guenther. (2006) Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty. Acta Orthopaedica 77:5, pages 697-705.
Read now
Georgios Digas. (2005) New polymer materials in total hip arthroplasty. Acta Orthopaedica 76:sup315, pages 4-82.
Read now
Tuomo Visuri, Eero Pukkala, Pekka Pulkkinen & Pekka Paavolainen. (2003) Decreased cancer risk in patients who have been operated on with total hip and knee arthroplasty for primary osteoarthrosis. Acta Orthopaedica Scandinavica 74:3, pages 351-360.
Read now
Alexander Pilger, Andreas Schaffer, Hugo W. Rüdiger & Wolf Osterode. (2002) URINARY 8-HYDROXYDEOXYGUANOSINE AND SISTER CHROMATID EXCHANGES IN PATIENTS WITH TOTAL HIP REPLACEMENTS. Journal of Toxicology and Environmental Health, Part A 65:9, pages 655-664.
Read now

Articles from other publishers (111)

Amol O. Bajaj, Rebecca Parker, Candice Farnsworth, Christian Law & Kamisha L. Johnson-Davis. (2023) Method validation of multi-element panel in whole blood by inductively coupled plasma mass spectrometry (ICP-MS). Journal of Mass Spectrometry and Advances in the Clinical Lab 27, pages 33-39.
Crossref
Gabriel Lee Álvarez-Rosado, Kevin Adrián Martínez-Hernández, Mario Alberto Camarillo-Ramos, Verónica Quintero-Rosas, Arnoldo Díaz-Ramírez & Roberto López-Avitia. (2022) Energy consumption of an internet of things development board. REVISTA DE CIENCIAS TECNOLÓGICAS 5:4, pages 376-386.
Crossref
Dominique Lison. 2022. Handbook on the Toxicology of Metals. Handbook on the Toxicology of Metals 221 242 .
Manuel Alejandro Cardona Salcedo, Mercedes Teresita Oropeza Guzmán, Grecia Isis Moreno Grijalva, Arturo Zizumbo López, Juan Antonio Paz González & Yadira Gochi Ponce. (2021) Polylactic acid/multi walled carbon nanotubes (PLA/MWCNT) nanocomposite for 3D printing of medical devices. REVISTA DE CIENCIAS TECNOLÓGICAS 4:4, pages 388-398.
Crossref
Chen-En Tsai, James Hung, Youxin Hu, Da-Yung Wang, Robert M. Pilliar & Rizhi Wang. (2021) Improving fretting corrosion resistance of CoCrMo alloy with TiSiN and ZrN coatings for orthopedic applications. Journal of the Mechanical Behavior of Biomedical Materials 114, pages 104233.
Crossref
Hong-Min Qin, Denise Herrera, Dian-Feng Liu, Chao-Qian Chen, Armen Nersesyan, Miroslav Mišík & Siegfried Knasmueller. (2020) Genotoxic properties of materials used for endoprostheses: Experimental and human data. Food and Chemical Toxicology 145, pages 111707.
Crossref
Kamisha L. Johnson-Davis, Candice Farnsworth, Christian Law & Rebecca Parker. (2020) Method validation for a multi-element panel in serum by inductively coupled plasma mass spectrometry (ICP-MS). Clinical Biochemistry 82, pages 90-98.
Crossref
Matthew Barrett Innes & Amber Reck Atwater. (2020) Orthopedic Implant Hypersensitivity Reactions. Dermatologic Clinics 38:3, pages 361-369.
Crossref
Tevfik OğurelSancar SerbestReyhan Oğurel, Uğur TiftikçiYaşar Ölmez. (2020) BLOOD CHROMIUM-COBALT LEVELS IN PATIENTS AFTER TOTAL KNEE ARTHROPLASTY AND THEIR EFFECT ON THE RETINAL NERVE FIBER LAYER AND MACULAR GANGLION CELL COMPLEX. Retina 40:6, pages 1200-1206.
Crossref
Joy-anne N. Oliver, Yingchao Su, Xiaonan Lu, Po-Hsuen Kuo, Jincheng Du & Donghui Zhu. (2019) Bioactive glass coatings on metallic implants for biomedical applications. Bioactive Materials 4, pages 261-270.
Crossref
J.S. Hayes & R.G. Richards. 2019. Encyclopedia of Biomedical Engineering. Encyclopedia of Biomedical Engineering 257 269 .
S S Das & P Chakraborti. (2018) Development of Biomaterial for Total Hip Joint Replacement. IOP Conference Series: Materials Science and Engineering 377, pages 012177.
Crossref
Zhang Guoqing, Yang Yongqiang, Song Changhui, Fu Fan & Zhang Zimian. (2017) Study on Biocompatibility of CoCrMo Alloy Parts Manufactured by Selective Laser Melting. Journal of Medical and Biological Engineering 38:1, pages 76-86.
Crossref
Yangping Liu & Jeremy L. Gilbert. (2018) The effect of simulated inflammatory conditions and Fenton chemistry on the electrochemistry of CoCrMo alloy. Journal of Biomedical Materials Research Part B: Applied Biomaterials 106:1, pages 209-220.
Crossref
Ben Green, Emily Griffiths & Solomon Almond. (2017) Neuropsychiatric symptoms following metal-on-metal implant failure with cobalt and chromium toxicity. BMC Psychiatry 17:1.
Crossref
Reshid Berber, Amna Abdel-Gadir, Stefania Rosmini, Gabriella Captur, Sabrina Nordin, Veronica Culotta, Luigi Palla, Peter Kellman, Guy W. Lloyd, John A. Skinner, James C. Moon, Charlotte Manisty & Alister J. Hart. (2017) Assessing for Cardiotoxicity from Metal-on-Metal Hip Implants with Advanced Multimodality Imaging Techniques. Journal of Bone and Joint Surgery 99:21, pages 1827-1835.
Crossref
Wenhao Wang & Kelvin W. K. Yeung. 2017. Orthopedic Biomaterials. Orthopedic Biomaterials 495 545 .
Charlotte Beddoes, Michael Whitehouse, Wuge Briscoe & Bo Su. (2016) Hydrogels as a Replacement Material for Damaged Articular Hyaline Cartilage. Materials 9:6, pages 443.
Crossref
Johannes A. Eckert, Ulrike Mueller, Sebastian Jaeger, Benjamin Panzram & J. Philippe Kretzer. (2016) Fretting and Corrosion in Modular Shoulder Arthroplasty: A Retrieval Analysis. BioMed Research International 2016, pages 1-7.
Crossref
Tan Di, Dai Mingjiang, Fu Wenbin, Lin Songsheng, Wei Chunbei & Zhao Mingchun. (2015) Performance of CoCrMo Alloy with Me-Doped DLC Coatings Prepared by a Magnetron Sputtering Method. Rare Metal Materials and Engineering 44:12, pages 2982-2986.
Crossref
Dominique Lison. 2015. Handbook on the Toxicology of Metals. Handbook on the Toxicology of Metals 743 763 .
Brian Scharf, Cristina C. Clement, Valerio Zolla, Giorgio Perino, Bo Yan, S. Gokhan Elci, E. Purdue, S. Goldring, Frank Macaluso, Neil Cobelli, Richard W. Vachet & Laura Santambrogio. (2014) Molecular analysis of chromium and cobalt-related toxicity. Scientific Reports 4:1.
Crossref
Shima Karimi & Akram M. Alfantazi. (2014) Ion release and surface oxide composition of AISI 316L, Co–28Cr–6Mo, and Ti–6Al–4V alloys immersed in human serum albumin solutions. Materials Science and Engineering: C 40, pages 435-444.
Crossref
Henryk Matusiewicz. (2014) Potential release of in vivo trace metals from metallic medical implants in the human body: From ions to nanoparticles – A systematic analytical review. Acta Biomaterialia 10:6, pages 2379-2403.
Crossref
H. John Cooper & Joshua J. Jacobs. 2014. Metal-on-Metal Bearings. Metal-on-Metal Bearings 135 151 .
Marcella Aquino & Tania Mucci. (2013) Systemic Contact Dermatitis and Allergy to Biomedical Devices. Current Allergy and Asthma Reports 13:5, pages 518-527.
Crossref
H. Tiusanen, K. Mäkelä, M. Kiilunen, P. Sarantsin, E. Sipola & M. Pesola. (2013) The Effect Of Different Bearing Surfaces On Metal Ion Levels In Urine Following 28 Mm Metal-On-Metal And 28 Mm Metal-On-Polyethylene Total Hip Arthroplasty. Scandinavian Journal of Surgery 102:3, pages 197-203.
Crossref
Katsuhiko Maezawa, Takahito Yuasa, Kentaro Aritomi, Seiki Ogawa, Yuichiro Maruyama, Masahiko Nozawa & Kazuo Kaneko. (2013) Chromium Level of Salvaged Blood in Patients Undergoing Revision Hip Arthroplasty. Journal of Orthopaedic Surgery 21:2, pages 195-198.
Crossref
Kevin F. Wiley, Kai Ding, Julie A. Stoner, David C. Teague & Khalid M. Yousuf. (2013) Incidence of Pseudotumor and Acute Lymphocytic Vasculitis Associated Lesion (ALVAL) Reactions in Metal-On-Metal Hip Articulations: A Meta-Analysis. The Journal of Arthroplasty 28:7, pages 1238-1245.
Crossref
Yoshimitsu Okazaki & Emiko Gotoh. (2013) Metal ion effects on different types of cell line, metal ion incorporation into L929 and MC3T3-E1 cells, and activation of macrophage-like J774.1 cells. Materials Science and Engineering: C 33:4, pages 1993-2001.
Crossref
Yirong Zeng & Wenjun Feng. (2013) Metal allergy in patients with total hip replacement: A review. Journal of International Medical Research 41:2, pages 247-252.
Crossref
H. John CooperJoshua J. JacobsJerrold B. Leikin, Regina M. BardenAaron G. Rosenberg. (2013) Elevated Serum Metal Levels from Vitamin Supplementation. JBJS Case Connector 3:1, pages e18.
Crossref
Henri Migaud, Sophie Putman, Antoine Combes, Charles Berton, Donatien Bocquet, Laurent Vasseur & Julien Girard. (2012) Metal-on-Metal Bearing: Is This the End of the Line? We Do Not Think So. HSS Journal ® 8:3, pages 262-269.
Crossref
Moeed Akbar, Alasdair R. Fraser, Gerard J. Graham, James M. Brewer & M. Helen Grant. (2012) Acute inflammatory response to cobalt chromium orthopaedic wear debris in a rodent air-pouch model. Journal of The Royal Society Interface 9:74, pages 2109-2119.
Crossref
Juliane Fritzsche, Cornelia Borisch & Christof Schaefer. (2012) Case Report: High Chromium and Cobalt Levels in a Pregnant Patient with Bilateral Metal-on-Metal Hip Arthroplasties. Clinical Orthopaedics and Related Research® 470:8, pages 2325-2331.
Crossref
S Catalani, MC Rizzetti, A Padovani & P Apostoli. (2011) Neurotoxicity of cobalt. Human & Experimental Toxicology 31:5, pages 421-437.
Crossref
Jacob P. Thyssen, Allan Roeske-Nielsen & Jeanne D. Johansen. (2011) Contact allergy and human biomonitoring - an overview with a focus on metals. Contact Dermatitis 65:3, pages 125-137.
Crossref
David H. Jang & Robert S. Hoffman. (2011) Heavy Metal Chelation in Neurotoxic Exposures. Neurologic Clinics 29:3, pages 607-622.
Crossref
Paul R. Kim, Paul E. Beaulé, Michael Dunbar, Joshua K.L. Lee, Nicholas Birkett, Michelle C. Turner, Nagarajkumar Yenugadhati, Vic Armstrong & Daniel Krewski. (2011) Cobalt and Chromium Levels in Blood and Urine Following Hip Resurfacing Arthroplasty with the Conserve Plus Implant. Journal of Bone and Joint Surgery 93:Supplement_2, pages 107-117.
Crossref
F. S. HaddadR. R. ThakrarA. J. HartJ. A. SkinnerA. V. F. NargolJ. F. NolanH. S. GillD. W. MurrayA. W. BlomC. P. Case. (2011) Metal-on-metal bearings. The Journal of Bone and Joint Surgery. British volume 93-B:5, pages 572-579.
Crossref
Juliana L. Basko-Plluska, Jacob P. Thyssen & Peter C. Schalock. (2011) Cutaneous and Systemic Hypersensitivity Reactions to Metallic Implants. Dermatitis 22:2, pages 65-79.
Crossref
A. Moroni, L. Savarino, M. Hoque, M. Cadossi & N. Baldini. (2010) Do Ion Levels In Hip Resurfacing Differ From Metal-on-metal THA at Midterm?. Clinical Orthopaedics and Related Research® 469:1, pages 180-187.
Crossref
R. M. deSouzaN. R. ParsonsT. OniP. DaltonM. CostaS. Krikler. (2010) Metal ion levels following resurfacing arthroplasty of the hip. The Journal of Bone and Joint Surgery. British volume 92-B:12, pages 1642-1647.
Crossref
Katsuhiko Maezawa, Masahiko Nozawa, Takahito Yuasa, Kentaro Aritomi, Keiji Matsuda & Katsuo Shitoto. (2010) Seven Years of Chronological Changes of Serum Chromium Levels After Metasul Metal-On-Metal Total Hip Arthroplasty. The Journal of Arthroplasty 25:8, pages 1196-1200.
Crossref
Ajay Malviya, Jayasree Ramaskandhan, James P. Holland & Elizabeth A. Lingard. (2010) Metal-on-Metal Total Hip Arthroplasty. Journal of Bone and Joint Surgery 92:7, pages 1675-1683.
Crossref
Jacob P. Thyssen & Torkil Menné. (2009) Metal Allergy—A Review on Exposures, Penetration, Genetics, Prevalence, and Clinical Implications. Chemical Research in Toxicology 23:2, pages 309-318.
Crossref
Monica Nordberg & Gunnar F. Nordberg. 2009. General and Applied Toxicology. General and Applied Toxicology.
Jacob Pontoppidan Thyssen, Kristina Milting, Anne Bregnhøj, Heidi Søsted, Jeanne Duus Johansen & Torkil Menné. (2009) Nickel allergy in patch‐tested female hairdressers and assessment of nickel release from hairdressers' scissors and crochet hooks. Contact Dermatitis 61:5, pages 281-286.
Crossref
D. Turcio-Ortega, S.E. Rodil & S. Muhl. (2009) Corrosion behavior of amorphous carbon deposit in 0.89% NaCl by electrochemical impedance spectroscopy. Diamond and Related Materials 18:11, pages 1360-1368.
Crossref
Bamikole Ogunwale, Andreas Schmidt-Ott, Dominic R. M. Meek & James M. Brewer. (2009) Investigating the Immunologic Effects of CoCr Nanoparticles. Clinical Orthopaedics & Related Research 467:11, pages 3010-3016.
Crossref
Katsuhiko Maezawa, Masahiko Nozawa, Keiji Matsuda, Munehiko Sugimoto, Katsuo Shitoto & Hisashi Kurosawa. (2009) Serum Chromium Levels Before and After Revision Surgery for Loosened Metal-On-Metal Total Hip Arthroplasty. The Journal of Arthroplasty 24:4, pages 549-553.
Crossref
Alexander Zeh, Claudia Becker, Michael Planert, Peter Lattke & David Wohlrab. (2008) Time-dependent release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick™ type artificial lumbar disc (Medtronic Sofamor Danek). Archives of Orthopaedic and Trauma Surgery 129:6, pages 741-746.
Crossref
Anton H. Hosman, Henny C. van der Mei, Sjoerd K. Bulstra, Henk J. Busscher & Daniëlle Neut. (2008) Metal‐on‐metal bearings in total hip arthroplasties: Influence of cobalt and chromium ions on bacterial growth and biofilm formation. Journal of Biomedical Materials Research Part A 88A:3, pages 711-716.
Crossref
Joshua J. Jacobs, Robert M. Urban, Nadim J. Hallab, Anastasia K. Skipor, Alfons Fischer & Markus A. Wimmer. (2009) Metal-on-metal Bearing Surfaces. Journal of the American Academy of Orthopaedic Surgeons 17:2, pages 69-76.
Crossref
J. DanielH. ZiaeeC. PradhanD. J. W. McMinn. (2009) Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings. The Journal of Bone and Joint Surgery. British volume 91-B:2, pages 176-179.
Crossref
Lucia Savarino, Giovanni Padovani, Massimo Ferretti, Michelina Greco, Elisabetta Cenni, Giorgio Perrone, Francesco Greco, Nicola Baldini & Armando Giunti. (2008) Serum ion levels after ceramic‐on‐ceramic and metal‐on‐metal total hip arthroplasty: 8‐year minimum follow‐up. Journal of Orthopaedic Research 26:12, pages 1569-1576.
Crossref
M. KhanJ.-H. KuiperJ. B. Richardson. (2008) The exercise-related rise in plasma cobalt levels after metal-on-metal hip resurfacing arthroplasty. The Journal of Bone and Joint Surgery. British volume 90-B:9, pages 1152-1157.
Crossref
Antonio Moroni, Lucia Savarino, Matteo Cadossi, Nicola Baldini & Sandro Giannini. (2008) Does Ion Release Differ Between Hip Resurfacing and Metal-on-metal THA?. Clinical Orthopaedics and Related Research 466:3, pages 700-707.
Crossref
P. Thomas, A. Schuh, J. Ring & M. Thomsen. (2008) Orthopädisch-chirurgische Implantate und AllergienOrthopedic surgical implants and allergies. Der Hautarzt 59:3, pages 220-229.
Crossref
Stefan Winter, Dirk Velten, Frank Aubertin, Frank Heidenau, Günter Ziegler, Frank A. Müller, Lenka Müller, Bettina Hoffmann, Volker Faust, Irina Dieser, Georg Lipps, Rainer Müller, Klaus Heckmann, Peter Angele, Richard Kujat, Michael Nerlich, David Tebbe, Uwe Gbureck, Roger Thull, Doris Klee, Jürgen Böing, Hartwig Höcker, Tilo Pompe, Carsten Werner & Hartmut Worch. 2008. Metallic Biomaterial Interfaces. Metallic Biomaterial Interfaces 51 116 .
P. Thomas, A. Schuh, J. Ring & M. Thomsen. (2007) Orthopädisch-chirurgische Implantate und AllergienOrthopedic surgical implants and allergies. Der Orthopäde 37:1, pages 75-88.
Crossref
J. -Y. Lazennec, P. Boyer, J. Poupon, M. -A. Rousseau, F. Laude, S. El Balkhi, Y. Catonne & G. Saillant. (2008) Second generation of metal-on-metal cemented total hip replacements: 12 years of clinical and biological follow-up. Interactive Surgery 2:3-4, pages 178-185.
Crossref
M Khan, J H Kuiper & J B Richardson. (2007) Can cobalt levels estimate in-vivo wear of metal-on-metal bearings used in hip arthroplasty? . Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 221:8, pages 929-942.
Crossref
I Bruce McPhee & Cheryl E. Swanson. (2007) Metal Ion Levels in Patients With Stainless Steel Spinal Instrumentation. Spine 32:18, pages 1963-1968.
Crossref
Joerg Luetzner, Frank Krummenauer, Attila Michael Lengel, Joerg Ziegler & Wolf-Christoph Witzleb. (2007) Serum Metal Ion Exposure after Total Knee Arthroplasty. Clinical Orthopaedics & Related Research 461, pages 136-142.
Crossref
G. M. KeeganI. D. LearmonthC. P. Case. (2007) Orthopaedic metals and their potential toxicity in the arthroplasty patient. The Journal of Bone and Joint Surgery. British volume 89-B:5, pages 567-573.
Crossref
S.K. Roy Chowdhury, A.C. Kulkarni, A. Basak & S.K. Roy. (2007) Wear characteristic and biocompatibility of some hydroxyapatite–collagen composite acetabular cups. Wear 262:11-12, pages 1387-1398.
Crossref
J.-Y. Lazennec, P. Boyer, J. Poupon, M.-A. Rousseau, F. Laude, Y. Catonne & G. Saillant. (2007) Prothèses métal-métal cimentées de seconde génération : 10 ans de suivi clinique et biologique. Revue de Chirurgie Orthopédique et Réparatrice de l'Appareil Moteur 93:3, pages 298-302.
Crossref
A W Hodgson, S Mischler, B Von Rechenberg & S Virtanen. (2007) An analysis of the in vivo deterioration of Co-Cr-Mo implants through wear and corrosion . Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 221:3, pages 291-303.
Crossref
Alexander Zeh, Michael Planert, Gabriele Siegert, Peter Lattke, Andreas Held & Werner Hein. (2007) Release of Cobalt and Chromium Ions Into the Serum Following Implantation of the Metal-on-Metal Maverick-Type Artificial Lumbar Disc (Medtronic Sofamor Danek). Spine 32:3, pages 348-352.
Crossref
A. Sargeant & T. Goswami. (2007) Hip implants – Paper VI – Ion concentrations. Materials & Design 28:1, pages 155-171.
Crossref
Chadi Tannoury, Erbil Oguz, Gordon H. Stock, Andrew K. Brown & D. Greg Anderson. 2007. Spinal Arthroplasty. Spinal Arthroplasty 95 104 .
DOMINIQUE LISON. 2007. Handbook on the Toxicology of Metals. Handbook on the Toxicology of Metals 511 528 .
Jean-Yves Lazennec, P. Boyer, J. Poupon, M. A. Rousseau, F. Laude, Y. Catonné & G. Saillant. 2007. Bioceramics and Alternative Bearings in Joint Arthroplasty. Bioceramics and Alternative Bearings in Joint Arthroplasty 249 259 .
Robert Legenstein, W. Huber & P. Boesch. 2007. Bioceramics and Alternative Bearings in Joint Arthroplasty. Bioceramics and Alternative Bearings in Joint Arthroplasty 193 203 .
Stephen B Murphy, Timo M Ecker & Moritz Tannast. (2006) Two- to 9-Year Clinical Results of Alumina Ceramic-on-Ceramic THA. Clinical Orthopaedics & Related Research 453, pages 97-102.
Crossref
Stephen B. Murphy, Timo Ecker, Moritz Tannast, Benjamin Bierbaum, Jonathan Garino, James Howe, Eric Hume, Richard Jones, Kristaps Keggi, Kenneth Kress, Daniel Phillips & Robert Zann. (2006) Experience in the United States with Alumina Ceramic–Ceramic Total Hip Arthroplasty. Seminars in Arthroplasty 17:3-4, pages 120-124.
Crossref
A. Grübl. (2006) Ergebnisse zementfreier HüftendoprothetikResults of cementless hip arthroplasty. Der Radiologe 46:9, pages 779-784.
Crossref
A. Grübl, M. WeissingerW. BrodnerA. GleissA. Giurea, M. Gruber, G. PöllV. MeisingerF. Gottsauner-WolfR. Kotz. (2006) Serum aluminium and cobalt levels after ceramic-on-ceramic and metal-on-metal total hip replacement. The Journal of Bone and Joint Surgery. British volume 88-B:8, pages 1003-1005.
Crossref
J. DanielH. ZiaeeA. SalamaC. PradhanD. J. W. McMinn. (2006) The effect of the diameter of metal-on-metal bearings on systemic exposure to cobalt and chromium. The Journal of Bone and Joint Surgery. British volume 88-B:4, pages 443-448.
Crossref
A. Sargeant & T. Goswami. (2006) Hip implants: Paper V. Physiological effects. Materials & Design 27:4, pages 287-307.
Crossref
P. Juhnke. 2006. Ossäre Integration. Ossäre Integration 120 125 .
Li Luo, Alain Petit, John Antoniou, David J. Zukor, Olga L. Huk, Roger C.W. Liu, Françoise M. Winnik & Fackson Mwale. (2005) Effect of cobalt and chromium ions on MMP-1, TIMP-1, and TNF-α gene expression in human U937 macrophages: A role for tyrosine kinases. Biomaterials 26:28, pages 5587-5593.
Crossref
Isabelle Catelas, Alain Petit, Hojatollah Vali, Cathy Fragiskatos, Réal Meilleur, David J. Zukor, John Antoniou & Olga L. Huk. (2005) Quantitative analysis of macrophage apoptosis vs. necrosis induced by cobalt and chromium ions in vitro. Biomaterials 26:15, pages 2441-2453.
Crossref
Matthew S. Austin, Michael Ciminiello & William J. Hozack. (2005) Total hip arthroplasty in the young patient. Seminars in Arthroplasty 16:1, pages 77-79.
Crossref
W. Baur, W. H�nle, H.-G. Willert & A. Schuh. (2005) Pathologische Ver�nderungen im umgebenden Gewebe von revidierten Metall-Metall-GleitpaarungenPathological findings in tissue surrounding revised metal/metal articulations. Der Orthop�de 34:3, pages 225-233.
Crossref
John H. Dumbleton & Michael T. Manley. (2005) Metal-on-Metal Total Hip Replacement. The Journal of Arthroplasty 20:2, pages 174-188.
Crossref
Kiyoshi NAKAGAWA. (2005) Determination of Nickel, Cobalt and Manganese in Serum by Graphite-Furnace AAS after Treatment at High Concentration of Ammonia高濃度アンモニア前処理/黒鉛炉原子吸光分析法による血清中のニッケル,コバルト,マンガンの定量. BUNSEKI KAGAKU 54:4, pages 301-305.
Crossref
B Hoffmann, A Kokott, O Shafranska, R Detsch, S Winter, E Eisenbarth, K Peters, J Breme, C. J Kirkpatrick & G Ziegler. (2005) Einfluss einer TiO2-Beschichtung auf Biokompatibilität, Korrosionsund Auslaugverhalten verschiedener Implantatlegierungen / Corrosion behaviour, metal release and biocompatibility of implant materials coated by TiO2-sol gel chemistry. Biomedizinische Technik/Biomedical Engineering 50:10, pages 320-329.
Crossref
Yoshimitsu Okazaki & Emiko Gotoh. (2005) Comparison of metal release from various metallic biomaterials in vitro. Biomaterials 26:1, pages 11-21.
Crossref
O. Niggemeyer, J. Steinhagen & W. Rüther. 2005. Hüfte. Hüfte 129 133 .
M. Manley & K. Sutton. 2005. Bioceramics and Alternative Bearings in Joint Arthroplasty. Bioceramics and Alternative Bearings in Joint Arthroplasty 191 195 .
Yoshimitsu Okazaki, Emiko Gotoh, Takeshi Manabe & Kihei Kobayashi. (2004) Comparison of metal concentrations in rat tibia tissues with various metallic implants. Biomaterials 25:28, pages 5913-5920.
Crossref
Wolfram Brodner, Josef Georg Grohs, Dagmar Bancher-Todesca, Ronald Dorotka, Vanee Meisinger, Florian Gottsauner-Wolf & Rainer Kotz. (2004) Does the placenta inhibit the passage of chromium and cobalt after metal-on-metal total hip arthroplasty?. The Journal of Arthroplasty 19:8, pages 102-106.
Crossref
Joshua J. Jacobs, Anastasia K. Skipor, Patricia A. Campbell, Nadim J. Hallab, Robert M. Urban & Harlan C. Amstutz. (2004) Can metal levels be used to monitor metal-on-metal hip arthroplasties?. The Journal of Arthroplasty 19:8, pages 59-65.
Crossref
Steven J. MacDonald. (2004) Can a safe level for metal ions in patients with metal-on-metal total hip arthroplasties be determined?. The Journal of Arthroplasty 19:8, pages 71-77.
Crossref
W.-C. Witzleb, A. Knecht, T. Beichler, T. K�hler & K.-P. G�nther. (2004) H�ftgelenk-Oberfl�chenersatzendoprothesenHip resurfacing arthroplasty. Der Orthop�de 33:11, pages 1236-1242.
Crossref
S.K Roy Chowdhury, A Mishra, B Pradhan & D Saha. (2004) Wear characteristic and biocompatibility of some polymer composite acetabular cups. Wear 256:11-12, pages 1026-1036.
Crossref
Steven J MacDonald. (2004) Letters to the Editor: Metal-on-Metal versus Polyethylene in Hip Arthroplasty: A Randomized Clinical Trial. Clinical Orthopaedics and Related Research 422, pages 271-272.
Crossref
F. Damie & L. Favard. (2004) Dosages sanguins de métaux chez 48 patients porteurs d’une prothèse totale de hanche en chrome-cobalt à couple métal-polyéthylène. Revue de Chirurgie Orthopédique et Réparatrice de l'Appareil Moteur 90:3, pages 241-248.
Crossref
Pat Campbell, Fu-Wen Shen & Harry McKellop. (2004) Biologic and Tribologic Considerations of Alternative Bearing Surfaces. Clinical Orthopaedics and Related Research 418, pages 98-111.
Crossref
Joshua J. Jacobs, Nadim J. Hallab, Anastasia K. Skipor & Robert M. Urban. (2003) Metal Degradation Products. Clinical Orthopaedics & Related Research 417, pages 139-147.
Crossref
WOLFRAM BRODNER, PETER BITZAN, VANEE MEISINGER, ALEXANDRA KAIDER, FLORIAN GOTTSAUNER-WOLF & RAINER KOTZ. (2003) SERUM COBALT LEVELS AFTER METAL-ON-METAL TOTAL HIP ARTHROPLASTY. The Journal of Bone and Joint Surgery-American Volume 85:11, pages 2168-2173.
Crossref
L. Savarino, D. Granchi, G. Ciapetti, E. Cenni, M. Greco, R. Rotini, C. A. Veronesi, N. Baldini & A. Giunti. (2003) Ion release in stable hip arthroplasties using metal‐on‐metal articulating surfaces: A comparison between short‐ and medium‐term results. Journal of Biomedical Materials Research Part A 66A:3, pages 450-456.
Crossref
Christian Lhotka, Thomas Szekeres, Ilse Steffan, Klaus Zhuber & Karl Zweymüller. (2006) Four‐year study of cobalt and chromium blood levels in patients managed with two different metal‐on‐metal total hip replacements. Journal of Orthopaedic Research 21:2, pages 189-195.
Crossref
Isabelle Catelas, Alain Petit, David J Zukor, John Antoniou & Olga L Huk. (2003) TNF-α secretion and macrophage mortality induced by cobalt and chromium ions in vitro-Qualitative analysis of apoptosis. Biomaterials 24:3, pages 383-391.
Crossref
Maria Eduarda Ferreira, Maria de Lourdes Pereira, Fernando Garcia e Costa, João Paulo Sousa & Graça Simões de Carvalho. (2003) Comparative study of metallic biomaterials toxicity: a histochemical and immunohistochemical demonstration in mouse spleen. Journal of Trace Elements in Medicine and Biology 17:1, pages 45-49.
Crossref
Petra Kajič, Ingrid Milošev, Boris Pihlar & Venčeslav Pišot. (2003) Determination of trace cobalt concentrations in human serum by adsorptive stripping voltammetry. Journal of Trace Elements in Medicine and Biology 17:3, pages 153-158.
Crossref
Stanley Manahan. 2002. Toxicological Chemistry and Biochemistry, Third Edition. Toxicological Chemistry and Biochemistry, Third Edition.
L. Savarino, D. Granchi, G. Ciapetti, E. Cenni, A. Nardi Pantoli, R. Rotini, C.A. Veronesi, N. Baldini & A. Giunti. (2002) Ion release in patients with metal-on-metal hip bearings in total joint replacement: A comparison with metal-on-polyethylene bearings. Journal of Biomedical Materials Research 63:5, pages 467-474.
Crossref
M Jagatia & Z M Jin. (2016) Elastohydrodynamic lubrication analysis of metal-on-metal hip prostheses under steady state entraining motion. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 215:6, pages 531-541.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.