1,751
Views
39
CrossRef citations to date
0
Altmetric
ORIGINAL ARTICLE

Hemolysis indexes for biochemical tests and immunoassays on Roche analyzers: Determination of allowable interference limits according to different calculation methods

, , , , , , , , , , , & show all
Pages 162-169 | Received 17 Aug 2014, Accepted 27 Nov 2014, Published online: 22 Jan 2015

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (4)

Anne-Birgitte Garm Blavnsfeldt, Tina Parkner & Cindy Soendersoe Knudsen. (2022) Plasma calprotectin – preanalytical stability and interference from hemolysis. Scandinavian Journal of Clinical and Laboratory Investigation 82:5, pages 349-355.
Read now
Paul R. Johnson, Shahram Shahangian & J. Rex Astles. (2021) Managing biological variation data: modern approaches for study design and clinical application. Critical Reviews in Clinical Laboratory Sciences 58:7, pages 493-512.
Read now
Charlotte Gils, Maria Boysen Sandberg & Mads Nybo. (2020) Verification of the hemolysis index measurement: imprecision, accuracy, measuring range, reference interval and impact of implementing analytically and clinically derived sample rejection criteria. Scandinavian Journal of Clinical and Laboratory Investigation 80:7, pages 580-589.
Read now
Gabriel Lima-Oliveira, Denis Monneret, Fabrice Guerber & Gian Cesare Guidi. (2018) Sample management for clinical biochemistry assays: Are serum and plasma interchangeable specimens?. Critical Reviews in Clinical Laboratory Sciences 55:7, pages 480-500.
Read now

Articles from other publishers (35)

Esraa Habiba, Samia Ali, Yehia Ghanem, Ola Sharaki & Wafaa Hewedy. (2023) Effect of oral versus parenteral vitamin D3 supplementation on nuclear factor-κB and platelet aggregation in type 2 diabetic patients. Canadian Journal of Physiology and Pharmacology 101:11, pages 610-619.
Crossref
José L. MARTÍN-CALDERÓN. (2023) Evaluation of endogenous interferences on several electrochemiluminescent immunoassays. La Rivista Italiana della Medicina di Laboratorio 18:4.
Crossref
G. Lippi, J. Cadamuro, A. von Meyer & A-M. Simundic. (2023) Practical recommendations for managing hemolyzed samples in clinical chemistry testing. Laboratornaya sluzhba 12:1, pages 40.
Crossref
Dimitrios Tsikas, Norbert Maassen, Antonie Thorns, Armin Finkel, Moritz Lützow, Magdalena Aleksandra Röhrig, Larissa Sarah Blau, Laurianne Dimina, François Mariotti, Bibiana Beckmann, Vladimir Shushakov & Mirja Jantz. (2022) Short-Term Supplementation of Sodium Nitrate vs. Sodium Chloride Increases Homoarginine Synthesis in Young Men Independent of Exercise. International Journal of Molecular Sciences 23:18, pages 10649.
Crossref
Daniel F DiToro, Michael J Conrad & Petr Jarolim. (2022) Hemolysis Index and Potassium Reporting. American Journal of Clinical Pathology 157:6, pages 809-813.
Crossref
Graham Ross Dallas Jones. (2022) Letter: Further issues with using reference change values. Clinica Chimica Acta 528, pages 13-14.
Crossref
Gang Tian, Yu Wu, Xinrui Jin, Zhangrui Zeng, Xiujuan Gu, Tao Li, Xiu Chen, Guangrong Li & Jinbo Liu. (2022) The incidence rate and influence factors of hemolysis, lipemia, icterus in fasting serum biochemistry specimens. PLOS ONE 17:1, pages e0262748.
Crossref
Noman NaeemKlaus-Stefan Drese, Lynn PatersonMaïwenn Kersaudy-Kerhoas. (2021) Current and Emerging Microfluidic-Based Integrated Solutions for Free Hemoglobin and Hemolysis Detection and Measurement. Analytical Chemistry 94:1, pages 75-85.
Crossref
Kamil UçarTahaTaha, Abdulkadir Çat, Alper Gümüş & Nilhan Nurlu. (2022) Interferograms plotted with reference change value (RCV) may facilitate the management of hemolyzed samples. Journal of Medical Biochemistry 41:1, pages 53-61.
Crossref
Sandhya Mainali, Anna E. Merrill & Matthew D. Krasowski. (2021) Frequency of icteric interference in clinical chemistry laboratory tests and causes of severe icterus. Practical Laboratory Medicine 27, pages e00259.
Crossref
Emilia C. Calvaresi, Sonia L. La’ulu, Taylor M. Snow, Tiffany R. Allison & Jonathan R. Genzen. (2021) Plasma hemoglobin: A method comparison of six assays for hemoglobin and hemolysis index measurement. International Journal of Laboratory Hematology 43:5, pages 1145-1153.
Crossref
Shuangqing Liu, Juan Li, Li Ning, Dawei Wu & Dianjun Wei. (2021) Assessing the influence of true hemolysis occurring in patient samples on emergency clinical biochemistry tests results using the VITROS ® 5600 Integrated system . Biomedical Reports 15:5.
Crossref
Isidor Minović, Lambert D. Dikkeschei, Michel J. Vos & Jenny E. Kootstra-Ros. (2021) Interpretation of Folate Results in Hemolytic Plasma Samples: A Practical Approach. Annals of Laboratory Medicine 41:5, pages 485-488.
Crossref
Oliver Clifford-Mobley & Sam Sheerin. (2020) Verifying the haemolysis index limit for non-reporting potassium. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine 58:4, pages 385-387.
Crossref
Tianqi Wang, Zeyu Li, Yuqing Jia, Baoli Zhu & Zhipeng Cao. (2021) Interference of hemolysis on the postmortem biochemical analysis of IgE by ECLIA. International Journal of Legal Medicine 135:4, pages 1661-1668.
Crossref
Karl Arne Johannessen, Nina Kristin Steen Wear, Karin Toska, Morten Hansbo, Jens Petter Berg & Erik Fosse. (2021) Pathologic Blood Samples Tolerate Exposure to Vibration and High Turbulence in Simulated Drone Flights, but Plasma Samples Should be Centrifuged After Flight. IEEE Journal of Translational Engineering in Health and Medicine 9, pages 1-10.
Crossref
Jun Ni, Wenbo Zhu, Yanyang Wang, Xuefei Wei, Jingjing Li, Lu Peng, Kui Zhang & Bing Bai. (2020) A Reference chart for clinical biochemical tests of hemolyzed serum samples. Journal of Clinical Laboratory Analysis 35:1.
Crossref
Claire E. Knezevic, Mary Ann Ness, Polly Hoi Ting Tsang, Brandon J. Tenney & Mark A. Marzinke. (2020) Establishing hemolysis and lipemia acceptance thresholds for clinical chemistry tests. Clinica Chimica Acta 510, pages 459-465.
Crossref
Berrak Güven, Abdülkadir Tekin & Murat Can. (2020) Effect of hemolysis on prealbumin assay. Turkish Journal of Biochemistry 45:5, pages 475-478.
Crossref
Anne Marie Dupuy, Anne Sophie Bargnoux, Nils Kuster, Jean Paul Cristol & Stéphanie Badiou. (2020) Determination of hemolysis cut-offs for biochemical and immunochemical analytes according to their value. Clinical Chemistry and Laboratory Medicine (CCLM) 58:8, pages 1232-1241.
Crossref
Raúl Rigo-Bonnin, Diego Muñoz-Provencio & Francesca Canalias. (2020) Reference change values based on uncertainty models. Clinical Biochemistry 80, pages 31-41.
Crossref
Mohiudeen Azhar, Sudipa Galgalkar, Ishita Chakraborty, Kalpesh Mehta, M.S. Ragavender, Vishal Prabhu & David Ledden. (2020) Hemolysis Detection in Sub-Microliter Volumes of Blood Plasma. IEEE Transactions on Biomedical Engineering 67:5, pages 1243-1252.
Crossref
Valérie Untereiner, Roselyne Garnotel, Gérard Thiéfin & Ganesh D. Sockalingum. (2019) Interference of hemolysis, hyperlipidemia, and icterus on plasma infrared spectral profile. Analytical and Bioanalytical Chemistry 412:4, pages 805-810.
Crossref
Jonna Karlén, Mathias Karlsson, Håkan Eliasson, Anna-Karin Edstedt Bonamy & Cecilia Pegelow Halvorsen. (2019) Cardiac Troponin T in Healthy Full-Term Infants. Pediatric Cardiology 40:8, pages 1645-1654.
Crossref
Francesca Trimboli, Fortunata Lucia, Elvira Angotti, Giulio Cesare Antico, Lorenzina Carinci Giacquinto, Maria Martucci, Serafina Mancuso, Roberta Chirillo, Domenico Britti, Giovanni Cuda, Francesco Costanzo & Camillo Palmieri. (2019) An approach based on simulated hemolysis for establishing the hemolysis index threshold for high-sensitivity cardiac troponin T assay. Clinical Chemistry and Laboratory Medicine (CCLM) 57:12, pages e314-e317.
Crossref
Gro Gidske, Kristin Moberg Aakre, Pål Rustad, Sverre Sandberg, Anna Norling, Jonna Pelanti, Gitte Henriksen, Ingunn Thorsteinsdottir & Gunn B.B. Kristensen. (2019) Handling of hemolyzed serum samples in clinical chemistry laboratories: the Nordic hemolysis project. Clinical Chemistry and Laboratory Medicine (CCLM) 57:11, pages 1699-1711.
Crossref
Selcuk Colak, Onur Tasdemir, Marianne van der Schaaf, Frans Opdam, Vincent van den Noort, Daan van den Broek & Huub H van Rossum. (2019) Design, validation and performance of aspartate aminotransferase- and lactate dehydrogenase-reporting algorithms for haemolysed specimens including correction within quality specifications. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, pages 000456321987847.
Crossref
Zhenhua Du, JiQin Liu, Hua Zhang, BuHe Bao, RuiQi Zhao & Ying Jin. (2019) Determination of hemolysis index thresholds for biochemical tests on Siemens Advia 2400 chemistry analyzer. Journal of Clinical Laboratory Analysis 33:4, pages e22856.
Crossref
Kong-Nan Zhao, Goce Dimeski, John de Jersey, Lambro A. Johnson, Michael Grant, Paul P. Masci & Martin F. Lavin. (2019) Next-generation rapid serum tube technology using prothrombin activator coagulant: fast, high-quality serum from normal samples. Clinical Chemistry and Laboratory Medicine (CCLM) 57:4, pages 483-497.
Crossref
Giuseppe Lippi, Janne Cadamuro, Alexander von Meyer & Ana-Maria Simundic. (2018) Practical recommendations for managing hemolyzed samples in clinical chemistry testing. Clinical Chemistry and Laboratory Medicine (CCLM) 56:5, pages 718-727.
Crossref
Denis Monneret, Martin Gellerstedt & Dominique Bonnefont-Rousselot. (2018) Determination of age- and sex-specific 99th percentiles for high-sensitive troponin T from patients: an analytical imprecision- and partitioning-based approach. Clinical Chemistry and Laboratory Medicine (CCLM) 56:5, pages 818-829.
Crossref
Alain Nicolay, Anne-Marie Lorec, Guy Gomez & Henri Portugal. (2018) Icteric human samples: Icterus index and method of estimating an interference-free value for 16 biochemical analyses. Journal of Clinical Laboratory Analysis 32:2, pages e22229.
Crossref
Sandhya Mainali, Scott R. Davis & Matthew D. Krasowski. (2017) Frequency and causes of lipemia interference of clinical chemistry laboratory tests. Practical Laboratory Medicine 8, pages 1-9.
Crossref
Denis Monneret. (2016) Potassium as a potential predictive biomarker of brain hypoxia in avalanche victims: preanalytical recommendations. The American Journal of Emergency Medicine 34:7, pages 1315-1316.
Crossref
Denis Monneret, Camille Corlouer, Jeanne Bigot, Gregory Atlan, Rana Alkouri, Fouzi Mestari, Sylvie Dever, Françoise Imbert-Bismut & Dominique Bonnefont-Rousselot. (2016) Comparison of a 10- vs. 15-min centrifugation time for chemical and immunochemical assays and impact on turnaround time in a hospital laboratory. Clinical Chemistry and Laboratory Medicine (CCLM) 54:4.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.