1,668
Views
17
CrossRef citations to date
0
Altmetric
Clinical Study

Differences in Bio-incompatibility among Four Biocompatible Dialyzer Membranes Using in Maintenance Hemodialysis Patients

, , , , &
Pages 682-691 | Received 16 Feb 2011, Accepted 11 May 2011, Published online: 25 Jul 2011

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (2)

Zhongxin Li, Lijie Ma & Sumei Zhao. (2016) Effect of polyflux membranes on the improvement of hemodialysis-associated eosinophilia: a case series. Renal Failure 38:1, pages 65-69.
Read now
Yuehong Li, Yujuan Wang, Jiaxuan Lv & Mei Wang. (2013) Clinical outcomes for maintenance hemodialysis patients using a high-flux (FX60) dialyzer. Renal Failure 35:9, pages 1240-1245.
Read now

Articles from other publishers (15)

Chuncheng Ma & Yemei Li. (2023) Clinical effect of different dialyzers used in patients with kidney disease: a meta-analysis of randomized clinical trials. Revista da Associação Médica Brasileira 69:1, pages 191-194.
Crossref
Chih‐Yu Chang, Mai‐Szu Wu, Chen‐Hao Chang, Chih‐Chieh Lin, Hsiang‐Ling Lin, Chih‐Chin Kao, Hsi‐Hsien Chen, Albert Li, Chih‐Cheng Hsu & Yen‐Chung Lin. (2021) Effect of dialyzer membranes on mortality in uremic patients undergoing long‐term hemodialysis: A Nationwide population‐based study using the Taiwan Dialysis Registry Data System 2005–2012. Therapeutic Apheresis and Dialysis 26:1, pages 55-63.
Crossref
Götz Ehlerding, Ansgar Erlenkötter, Adelheid Gauly, Bettina Griesshaber, James Kennedy, Lena Rauber, Wolfgang Ries, Hans Schmidt-Gürtler, Manuela Stauss-Grabo, Stephan Wagner, Adam M. Zawada, Sebastian Zschätzsch & Manuela Kempkes-Koch. (2021) Performance and Hemocompatibility of a Novel Polysulfone Dialyzer: A Randomized Controlled Trial. Kidney360 2:6, pages 937-947.
Crossref
Neda Mahmoudi, Jesse Roberts, Grant Harrison, Nawaf Alshammari, Jamie Hestekin & Shannon L. Servoss. (2019) Low Fouling, Peptoid-Coated Polysulfone Hollow Fiber Membranes—the Effect of Grafting Density and Number of Side Chains. Applied Biochemistry and Biotechnology 191:2, pages 824-837.
Crossref
Stephan Wagner, Sebastian Zschätzsch, Ansgar Erlenkoetter, Lena Rauber, Manuela Stauss-Grabo & Adelheid Gauly. (2020) Hemocompatibility of Polysulfone Hemodialyzers – Exploratory Studies on Impact of Treatment Modality and Dialyzer Characteristics. Kidney360 1:1, pages 25-35.
Crossref
Jiayi Yang, Jinjin Fan, Li Fan, Chunyan Yi, Jianxiong Lin, Haiping Mao, Xiao Yang & Xin Wang. (2020) Higher Eosinophils Predict Death-Censored Technique Failure in Peritoneal Dialysis Patients. International Archives of Allergy and Immunology 181:10, pages 765-773.
Crossref
Philipp Gauckler, Jae Shin, Gert Mayer & Andreas Kronbichler. (2018) Eosinophilia and Kidney Disease: More than Just an Incidental Finding?. Journal of Clinical Medicine 7:12, pages 529.
Crossref
Wen-Sheng Liu, Hsiang Chan, Yen-Ting Lai, Chih-Ching Lin, Szu-Yuan Li, Chih-Kuang Liu, Han-Hsing Tsou & Tsung-Yun Liu. (2018) Dialysis Membranes Influence Perfluorochemical Concentrations and Liver Function in Patients on Hemodialysis. International Journal of Environmental Research and Public Health 15:11, pages 2574.
Crossref
Maurizio Ronci, Lidia Leporini, Paolo Felaco, Vittorio Sirolli, Luisa Pieroni, Viviana Greco, Antonio Aceto, Andrea Urbani & Mario Bonomini. (2018) Proteomic Characterization of a New asymmetric Cellulose Triacetate Membrane for Hemodialysis. PROTEOMICS - Clinical Applications 12:6, pages 1700140.
Crossref
Michio Mineshima. (2017) . Nihon Toseki Igakkai Zasshi 50:6, pages 363-399.
Crossref
Sarah Hildebrand, Richard Corbett, Neill Duncan & Damien Ashby. (2016) Increased prevalence of eosinophilia in a hemodialysis population: Longitudinal and case control studies. Hemodialysis International 20:3, pages 414-420.
Crossref
Shaojin Gu, Huan Xia, Jiehao Du, Ling Yang, Yajun Cai, Yingshan Zhou & Jingjing Huang. (2016) Surface modification of polysulfones via one-pot ATRP and click chemistry: Zwitterionic graft complex and their hemocompatibility. Fibers and Polymers 17:2, pages 161-165.
Crossref
P. Susantitaphong, M. Siribamrungwong & B. L. Jaber. (2013) Convective therapies versus low-flux hemodialysis for chronic kidney failure: a meta-analysis of randomized controlled trials. Nephrology Dialysis Transplantation 28:11, pages 2859-2874.
Crossref
Ivana Pešić, Gerhard A. Müller, Cosima Baumann, Gry H. Dihazi, Michael J. Koziolek, Marwa Eltoweissy, Carsten Bramlage, Abdul R. Asif & Hassan Dihazi. (2013) Cellulose membranes are more effective in holding back vital proteins and exhibit less interaction with plasma proteins during hemodialysis. Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics 1834:4, pages 754-762.
Crossref
Suetonia C Palmer, Kannaiyan S Rabindranath, Jonathan C Craig, Paul J Roderick, Francesco Locatelli & Giovanni FM Strippoli. (2012) High-flux versus low-flux membranes for end-stage kidney disease. Cochrane Database of Systematic Reviews.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.