Wear of the polyethylene acetabular cup: Metallic and ceramic heads compared in a hip simulator

, &
Pages 391-402 | Received 03 May 1993, Accepted 19 Jan 1993, Published online: 08 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (9)

Aniket Kunal Bhawe, Kavish Maulik Shah, Samridhi Somani, Satish Shenoy B, Shyamasunder Bhat N, Mohammad Zuber & Chethan K N. (2022) Static structural analysis of the effect of change in femoral head sizes used in Total Hip Arthroplasty using finite element method. Cogent Engineering 9:1.
Read now
Yohei Naito, Masahiro Hasegawa, Shine Tone, Hiroki Wakabayashi & Akihiro Sudo. (2021) Thirteen-year results of cementless total hip arthroplasty with zirconia heads on highly cross-linked polyethylene. Modern Rheumatology 31:5, pages 1045-1049.
Read now
PaulA. Williams, Kengo Yamamoto, Toshinori Masaoka, Hironobu Oonishi & IanC. Clarke. (2007) Highly Crosslinked Polyethylenes in Hip Replacements: Improved Wear Performance or Paradox?. Tribology Transactions 50:2, pages 277-290.
Read now
Masahiro Hasegawa, Toshiro Ohashi & Tomohisa Tani. (2001) Poor outcome of 44 cemented total hip arthroplasties with alumina ceramic heads: Clinical evaluation and retrieval analysis after 10-16 years. Acta Orthopaedica Scandinavica 72:5, pages 449-456.
Read now
Harm M van der Vis, Rob Zwartelé, Hans M Schüller, H Kees Doets & Rene K Marti. (1998) Socket wear in ceramic-on-polyethylene total hip arthroplasties Fixed versus rotating heads. Acta Orthopaedica Scandinavica 69:3, pages 248-252.
Read now
William H Harris. (1994) Osteolysis and particle disease in hip replacement: A review. Acta Orthopaedica Scandinavica 65:1, pages 113-123.
Read now
Rik Huiskes. (1993) Failed innovation in total hip replacement: Diagnosis and proposals for a cure. Acta Orthopaedica Scandinavica 64:6, pages 699-716.
Read now

Articles from other publishers (77)

Cristina Suárez, Alejandra Forero, Daniel Monsalvo, Alejandra Taborda & Dario Londoño. (2020) Evaluación costo-efectividad de las prótesis con superficie cerámica-polietileno vs. metal-polietileno para reemplazo articular primario de cadera en Colombia. Revista Colombiana de Ortopedia y Traumatología 34:3, pages 223-230.
Crossref
T. Matsushita & H. Takahashi. 2019. Metals for Biomedical Devices. Metals for Biomedical Devices 431 473 .
. 2019. Alumina Ceramics. Alumina Ceramics 509 539 .
Patricia O. Cubillos, Vinícius O. dos Santos, André Luiz A. Pizzolatti, Edison da Rosa & Carlos R.M. Roesler. (2018) Evaluation of Surface Finish and Dimensional Control of Tribological Metal-Ultra High Molecular Weight Polyethylene Pair of Commercially Available Hip Implants. The Journal of Arthroplasty 33:3, pages 939-944.
Crossref
D. Huten, H. Common, T. Gicquel & F. Basselot. 2017. La Prothèse Totale de Hanche dans Tous ses états. La Prothèse Totale de Hanche dans Tous ses états 99 112 .
S.L. Smith & T.J. Joyce. 2017. Mechanical Testing of Orthopaedic Implants. Mechanical Testing of Orthopaedic Implants 183 206 .
Paola Taddei, Silvia Tozzi, Simone Carmignato & Saverio Affatato. (2016) May the surface roughness of the retrieved femoral head influence the wear behavior of the polyethylene liner?. Journal of Biomedical Materials Research Part B: Applied Biomaterials 104:7, pages 1374-1385.
Crossref
Murat Ali, Mazen Al-Hajjar, Susan Partridge, Sophie Williams, John Fisher & Louise M Jennings. (2016) Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 230:5, pages 389-397.
Crossref
Y-H. KimJ-W. ParkJ-S. Kim. (2015) Isolated revision of an acetabular component to a ceramic-on-ceramic bearing in patients under 50 years of age. The Bone & Joint Journal 97-B:9, pages 1197-1203.
Crossref
Sachiyuki Tsukada, Motohiro Wakui & Munenori Matsueda. (2013) Uncemented third-generation ceramic-on-ceramic total hip arthroplasty using metal acetabular shell with direct taper locking liner. Archives of Orthopaedic and Trauma Surgery 133:6, pages 861-868.
Crossref
C. M. JackD. O. MolloyW. L. WalterB. A. ZicatW. K. Walter. (2013) The use of ceramic-on-ceramic bearings in isolated revision of the acetabular component. The Bone & Joint Journal 95-B:3, pages 333-338.
Crossref
Won-Sik ChoyKap Jung KimSang Ki LeeKyoung Wan BaeYoon Sub HwangChang Kyu Park. (2013) Ceramic-on-Ceramic Total Hip Arthroplasty: Minimum of Six-Year Follow-up Study. Clinics in Orthopedic Surgery 5:3, pages 174.
Crossref
X. Flecher, S. Parratte,J.M. Aubaniac & J.N. Argenson,. 2013. Wear of Orthopaedic Implants and Artificial Joints. Wear of Orthopaedic Implants and Artificial Joints 298 309 .
Francesco Benazzo, Loris Perticarini, Claudia Russo & Alberto Combi. 2013. Total Hip Arthroplasty. Total Hip Arthroplasty 27 35 .
Taishi Sato, Yasuharu Nakashima, Mio Akiyama, Takuaki Yamamoto, Taro Mawatari, Takashi Itokawa, Masanobu Ohishi, Goro Motomura, Masanobu Hirata & Yukihide Iwamoto. (2012) Wear resistant performance of highly cross-linked and annealed ultra-high molecular weight polyethylene against ceramic heads in total hip arthroplasty. Journal of Orthopaedic Research 30:12, pages 2031-2037.
Crossref
Taishi Sato, Yasuharu Nakashima, Mio Akiyama, Takuaki Yamamoto, Taro Mawatari, Takashi Itokawa, Masanobu Ohishi, Goro Motomura, Masanobu Hirata & Yukihide Iwamoto. (2012) Comparison of Polyethylene Wear between Highly Crosslinked and Annealed UHMWPE and Conventional UHMWPE against Ceramic Heads in Total Hip Arthroplasty. Key Engineering Materials 529-530, pages 279-284.
Crossref
Feng-Chih Kuo, Hao-Chen Liu, Wun-Schen Chen & Jun-Wen Wang. (2012) Ceramic-on-ceramic Total Hip Arthroplasty: Incidence and Risk Factors of Bearing Surface–related Noises in 125 Patients. Orthopedics 35:11.
Crossref
Allison Brown, Yatin Kirane & Zakary Knutson. 2012. Osteoarthritis: Linking Basic Science to Intervention. Osteoarthritis: Linking Basic Science to Intervention 1 47 .
A P Harsha & T J Joyce. (2011) Challenges associated with using bovine serum in wear testing orthopaedic biopolymers. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 225:10, pages 948-958.
Crossref
Tomiharu MATSUSHITA & Tadashi KOKUBO. (2010) Performance Improvement of Joint Prosthesis and Its Future Tasks. Journal of the Japan Society for Technology of Plasticity 51:590, pages 182-186.
Crossref
T. Matsushita. 2010. Metals for Biomedical Devices. Metals for Biomedical Devices 329 354 .
Jun-Dong Chang, Rutuj Kamdar, Je-Hyun Yoo, Mina Hur & Sang-Soo Lee. (2009) Third-Generation Ceramic-on-Ceramic Bearing Surfaces in Revision Total Hip Arthroplasty. The Journal of Arthroplasty 24:8, pages 1231-1235.
Crossref
William N. Capello, James A. D'Antonio, Judy R. Feinberg, Michael T. Manley & Marybeth Naughton. (2008) Ceramic-on-Ceramic Total Hip Arthroplasty: Update. The Journal of Arthroplasty 23:7, pages 39-43.
Crossref
Zhinian Wan, Myriam Boutary & Lawrence D. Dorr. (2008) The Influence of Acetabular Component Position on Wear in Total Hip Arthroplasty. The Journal of Arthroplasty 23:1, pages 51-56.
Crossref
V?ctor M. Ilizaliturri S?nchez, Gerardo Mangino Pariente & Javier Camacho Galindo. (2007) Tratamiento quir?rgico de la osteoartritis en la cadera: actualidades en artroplastia total de cadera. Reumatolog?a Cl?nica 3, pages S57-S62.
Crossref
S. Affatato, A. Leardini, W. Leardini, S. Giannini & M. Viceconti. (2007) Meniscal wear at a three-component total ankle prosthesis by a knee joint simulator. Journal of Biomechanics 40:8, pages 1871-1876.
Crossref
Young-Ho Kim. 2007. Bioceramics and Alternative Bearings in Joint Arthroplasty. Bioceramics and Alternative Bearings in Joint Arthroplasty 49 57 .
James A. D’Antonio, William N. Capello, Benjamin Bierbaum, Michael Manley & Marybeth Naughton. (2006) Ceramic-on-Ceramic Bearings for Total Hip Arthroplasty: 5-9 Year Follow-Up. Seminars in Arthroplasty 17:3-4, pages 146-152.
Crossref
L.M. Brunner & T.A. Tervoort. 2006. Encyclopedia of Materials: Science and Technology. Encyclopedia of Materials: Science and Technology 1 8 .
D. A. Dennis, R. D. Komistek & M. R. Mahfouz. 2006. Bioceramics and Alternative Bearings in Joint Arthroplasty. Bioceramics and Alternative Bearings in Joint Arthroplasty 81 92 .
James A D???Antonio, William N Capello, Michael T Manley, Marybeth Naughton & Kate Sutton. (2005) A Titanium-encased Alumina Ceramic Bearing for Total Hip Arthroplasty. Clinical Orthopaedics and Related Research 441:&NA;, pages 151-158.
Crossref
James D???Antonio, William Capello, Michael Manley, Marybeth Naughton & Kate Sutton. (2005) Alumina Ceramic Bearings for Total Hip Arthroplasty. Clinical Orthopaedics and Related Research &NA;:436, pages 164-171.
Crossref
Keiichi Kawanabe, Kenji Tanaka, Jiro Tamura, Motoyuki Shimizu, Eijiro Onishi, Hirokazu Iida & Takashi Nakamura. (2005) Effect of alumina femoral head on clinical results in cemented total hip arthroplasty: old versus current alumina. Journal of Orthopaedic Science 10:4, pages 378-384.
Crossref
YOUNG-HOO KIM, ALLAN RITCHIE & CATH HARDAKER. (2005) SURFACE ROUGHNESS OF CERAMIC FEMORAL HEADS AFTER IN VIVO TRANSFER OF METAL. The Journal of Bone and Joint Surgery-American Volume 87:3, pages 577-582.
Crossref
M. Manley & K. Sutton. 2005. Bioceramics and Alternative Bearings in Joint Arthroplasty. Bioceramics and Alternative Bearings in Joint Arthroplasty 191 195 .
G. de la Herrán & J. Usabiaga. (2004) Propiedades de lubricación del líquido sinovial en la artroplastia total de cadera. Revista Española de Cirugía Ortopédica y Traumatología 48:3, pages 218-224.
Crossref
B. E. Bierbaum, J. D’Antonio, W. Capello, M. Manley & R. Deshmukh. 2004. Bioceramics in Joint Arthroplasty. Bioceramics in Joint Arthroplasty 21 34 .
EDUARDO GARCIA-CIMBRELO, ANA CRUZ-PARDOS, ROSARIO MADERO & MIGUEL ORTEGA-ANDREU. (2003) TOTAL HIP ARTHROPLASTY WITH USE OF THE CEMENTLESS ZWEYMÜLLER ALLOCLASSIC SYSTEM. The Journal of Bone and Joint Surgery-American Volume 85:2, pages 296-303.
Crossref
James D'Antonio, William Capello & Michael Manley. (2003) Alumina Ceramic Bearings for Total Hip Arthroplasty. Orthopedics 26:1, pages 39-46.
Crossref
Ch. Hendrich, S. Goebel, Ch. Roller, S. Kirschner & J. M. Martell. 2003. Bioceramics in Joint Arthroplasty. Bioceramics in Joint Arthroplasty 177 182 .
RICHARD D. KOMISTEK, DOUGLAS A. DENNIS, JORGE A. OCHOA, BRIAN D. HAAS & CURT HAMMILL. (2002) IN VIVO COMPARISON OF HIP SEPARATION AFTER METAL-ON-METAL OR METAL-ON-POLYETHYLENE TOTAL HIP ARTHROPLASTY. The Journal of Bone and Joint Surgery-American Volume 84:10, pages 1836-1841.
Crossref
James D'Antonio, William Capello, Michael Manley & Benjamin Bierbaum. (2002) New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty. The Journal of Arthroplasty 17:4, pages 390-397.
Crossref
S. Affatato, B. Bordini, C. Fagnano, P. Taddei, A. Tinti & A. Toni. (2002) Effects of the sterilisation method on the wear of UHMWPE acetabular cups tested in a hip joint simulator. Biomaterials 23:6, pages 1439-1446.
Crossref
Keiji Haraguchi, Nobuhiko Sugano, Takashi Nishii, Takashi Sakai, Hideki Yoshikawa & Kenji Ohzono. (2001) Analysis of Survivorship After Total Hip Arthroplasty Using a Ceramic Head. Clinical Orthopaedics and Related Research 391, pages 198-209.
Crossref
S. Affatato, B. Fernandes, A. Tucci, L. Esposito & A. Toni. (2001) Isolation and morphological characterisation of UHMWPE wear debris generated in vitro. Biomaterials 22:17, pages 2325-2331.
Crossref
Durgadas P. Sakalkale, Peter F. Sharkey, Kenneth Eng, William J. Hozack & Richard H. Rothman. (2001) Effect of Femoral Component Offset on Polyethylene Wear in Total Hip Arthroplasty. Clinical Orthopaedics and Related Research 388, pages 125-134.
Crossref
Douglas A. Dennis, Richard D. Komistek, Eric J. Northcut, Jorge A. Ochoa & Allan Ritchie. (2001) “In vivo” determination of hip joint separation and the forces generated due to impact loading conditions. Journal of Biomechanics 34:5, pages 623-629.
Crossref
S Affatato. (2001) Mixed oxides prosthetic ceramic ball heads. Part 3: effect of the ZrO2 fraction on the wear of ceramic on ceramic hip joint prostheses. A long-term in vitro wear study. Biomaterials 22:7, pages 717-723.
Crossref
H. Graichen & L. Zichner. 2001. Verankerungsprinzipien in der Hüftendoprothetik. Verankerungsprinzipien in der Hüftendoprothetik 16 21 .
Ian C. Clarke & Allen Gustafson. (2000) Clinical and Hip Simulator Comparisons of Ceramic-on-Polyethylene and Metal-on-Polyethylene Wear. Clinical Orthopaedics and Related Research 379, pages 34-40.
Crossref
Adolph V. LombardiJrJr, Thomas H. Mallory, Douglas A. Dennis, Richard D. Komistek, Robert A. Fada & Eric J. Northcut. (2000) An in vivo determination of total hip arthroplasty pistoning during activity. The Journal of Arthroplasty 15:6, pages 702-709.
Crossref
S. Affatato, E. Ghisolfi, G.L. Cacciari & A. Toni. (2018) Alumina Femoral Head Fracture: An in Vitro Study. The International Journal of Artificial Organs 23:4, pages 256-260.
Crossref
I. Bos. (2018) Histological Investigation of Polyethylene Particles in Total Hip Replacement: Ceramic versus Metal Heads. HIP International 10:3, pages 151-160.
Crossref
Marius von Knoch, Charles A. EnghSrSr, Christi J. Sychterz, C. Anderson EnghJrJr & Hans-Georg Willert. (2000) Migration of polyethylene wear debris in one type of uncemented femoral component with circumferential porous coating. The Journal of Arthroplasty 15:1, pages 72-78.
Crossref
S. Affatato, M. Frigo & A. Toni. (2000) Anin vitro investigation of diamond-like carbon as a femoral head coating. Journal of Biomedical Materials Research 53:3, pages 221-226.
Crossref
S. Affatato, M. Testoni, G.L. Cacciari & A. Toni. (1999) Mixed-oxides prosthetic ceramic ball heads. Part II: effect of the ZrO2 fraction on the wear of ceramic on ceramic joints. Biomaterials 20:20, pages 1925-1929.
Crossref
S. Affatato, M. Tagliati & A. Toni. (2018) Hip Prothesis: An in Vitro Wear Protocol Based on a Comparison between Gravimetric and Profilometric Analysis. The International Journal of Artificial Organs 22:4, pages 226-229.
Crossref
Pekka Paavolainen, Eero Pukkala, Pekka Pulkkinen & Tuomo Visuri. (1999) Cancer incidence in finnish hip replacement patients from 1980 to 1995. The Journal of Arthroplasty 14:3, pages 272-280.
Crossref
Christi J. Sychterz, C. Anderson EnghJr.Jr., Steven W. Swope, Donald E. McNulty & Charles A. Engh. (1999) Analysis of Prosthetic Femoral Heads Retrieved at Autopsy. Clinical Orthopaedics and Related Research 358, pages 223???234.
Crossref
Vesa Saikko. (1998) A multidirectional motion pin-on-disk wear test method for prosthetic joint materials. Journal of Biomedical Materials Research 41:1, pages 58-64.
Crossref
Wesley P. Phipatanakul, Sherry A. Johnson, Victoria Good & Ian C. Clarke. (1998) The fallacy of evaluating biomaterial wear-rates with water as lubricant: A hip simulator study of alumina-PTFE and CoCr-PTFE combinations. Journal of Biomedical Materials Research 39:2, pages 229-233.
Crossref
Jordan A. Simon, Alan J. Dayan, Enrique Ergas, Steven A. Stuchin & Paul E. Di Cesare. (1998) Catastrophic failure of the acetabular component in a ceramic-polyethylene bearing total hip arthroplasty. The Journal of Arthroplasty 13:1, pages 108-113.
Crossref
Tiina Ahlroos & Vesa Saikko. (1997) Wear of prosthetic joint materials in various lubricants. Wear 211:1, pages 113-119.
Crossref
R J A Bigsby, C S Hardaker & J Fisher. (1997) Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 211:3, pages 265-269.
Crossref
Z Lu & H McKellop. (2005) Frictional heating of bearing materials tested in a hip joint wear simulator. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 211:1, pages 101-108.
Crossref
J B Medley, J J Krygier, J D Bobyn, F W Chan, A Lippincott & M Tanzer. (2005) Kinematics of the MATCO™ hip simulator and issues related to wear testing of metal-metal implants. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 211:1, pages 89-99.
Crossref
J G Lancaster, D Dowson, G H Isaac & J Fisher. (2005) The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 211:1, pages 17-24.
Crossref
G. Willmann, H.J. Früh & H.G. Pfaff. (1996) Wear characteristics of sliding pairs of zirconia (Y-TZP) for hip endoprostheses. Biomaterials 17:22, pages 2157-2162.
Crossref
R M Hall, A Unsworth, P Siney & B M Wroblewski. (2016) Wear in Retrieved Charnley Acetabular Sockets. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 210:3, pages 197-207.
Crossref
Vesa O Saikko. (2016) A Three-Axis Hip Joint Simulator for Wear and Friction Studies on Total Hip Prostheses. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 210:3, pages 175-185.
Crossref
Jonathan Black. (1996) Metal on Metal Bearings. Clinical Orthopaedics and Related Research 329, pages S244-S255.
Crossref
John B. Medley, Frank W. Chan, Jan J. Krygier & J. Dennis Bobyn. (1996) Comparison of Alloys and Designs in a Hip Simulator Study of Metal on Metal Implants. Clinical Orthopaedics and Related Research 329, pages S148-S159.
Crossref
Per Aspenberg, Asko Anttila, Yrjo T. Konttinen, Reijo Lappalainen, Stuart B. Goodman, Lars Nordsletten & Seppo Santavirta. (1996) Benign response to particles of diamond and SiC: bone chamber studies of new joint replacement coating materials in rabbits. Biomaterials 17:8, pages 807-812.
Crossref
Victoria D. Good, Ian C. Clarke & Lucas Anissian. (1996) Water and bovine serum lubrication compared in simulator PTFE/CoCr wear model. Journal of Biomedical Materials Research 33:4, pages 275-283.
Crossref
R M Hall, A Unsworth, P S Craig, C Hardaker, P Siney & B M Wroblewski. (2016) Measurement of Wear in Retrieved Acetabular Sockets. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 209:4, pages 233-242.
Crossref
V. Saikko. (1994) Wear of polyethylene acetabular cups against zirconia femoral heads studied with a hip joint simulator. Wear 176:2, pages 207-212.
Crossref
B. Derbyshire, J. Fisher, D. Dowson, C. Hardaker & K. Brummitt. (1994) Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints. Medical Engineering & Physics 16:3, pages 229-236.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.