Objective assessment of eyelid position and tear meniscus in facial nerve palsy

ORCID Icon, , & ORCID Icon
Pages 700-707 | Received 26 May 2021, Accepted 07 Oct 2021, Published online: 27 Dec 2021
 

ABSTRACT

Purpose

To evaluate lower lid position and tear meniscus in peripheral idiopathic facial nerve palsy (FNP).

Methods

A prospective study enrolled patients with peripheral idiopathic FNP and epiphora. Data were collected on patient demographics, House-Brackmann (HB) scale, digital photographs of the face, and tear meniscus at the 1st, 30, and 90 day after onset of FNP. Marginal reflex distance to the upper (MRD1) and lower eyelid (MRD2) were evaluated using ImageJ software. Anterior segment optical coherence tomography (OCT) was performed to measure the tear menis- cus. P< .05 was considered statistically significant.

Results

Sixteen patients were evaluated. The HB scale at presentation was grade III in six patients (37.5%). At 90 day, nine patients (56.25%) were grade I-normal. Three (18.7%) had upper lid retraction, three (18.7%) upper eyelid asymmetry and 7 (43.75%), lower eyelid retraction. The difference between MRD2-FNP with MRD2-healthy side was 0.51 ± 1.9 mm at the 1st visit, decreasing to 0.09 ± 1.47 mm at 90 days (P= .877). Tear meniscus measurements were significantly higher in FNP at the 1st visit (P= .001). The decrease in MRD2 was statistically correlated with the reduction of the tear meniscus area (TMA) (r = 0.67; P= .007) at 90 days. No correlation was found between HB and TMA. There is a difference in TMA between age groups at the 1st day(p= .009). Eldest group had higher HB scales.

Conclusion

Quantitative evaluation of eyelid position and tear meniscus are effective to document the evolution of FNP and can serve as a clue of orbicularis recovery.

Acknowlegdment

To all who collaborated in patient data collection and the English Editor (Proofreading).

Disclosure statement

No potential conflict of interest was reported by the author(s).

Additional information

Funding

The author(s) reported there is no funding associated with the work featured in this article.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 733.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.