1,187
Views
8
CrossRef citations to date
0
Altmetric
Preliminary Report

Head-Neck Motion in Prehospital Trauma Patients under Spinal Motion Restriction: A Pilot Study

, MPhil, ACP, , PhD, , MD, FRCPC (EM) & , CAT(C), PhD
Pages 117-124 | Received 29 Sep 2019, Accepted 04 Feb 2020, Published online: 18 Mar 2020
 

Abstract

Background

Spinal precautions are intended to limit motion of potentially unstable spinal segments. The efficacy of various treatment approaches for motion restriction in the cervical spine has been rigorously investigated using healthy volunteers and, to a lesser extent, cadaver samples. No previous studies have objectively measured this motion in trauma patients with potential spine injuries during prehospital care. Objective: The purpose of this study was to characterize head-neck (H-N) kinematics in a sample of trauma patients receiving spinal precautions in the field. Methods: This was a prospective observational study of trauma patients in the prehospital setting. Trauma patients meeting criteria for spinal precautions were eligible for inclusion. Participants received usual care, consisting of either a long backboard, cervical collar, and head blocks (BC) or a cervical collar only (CO), and behavior was categorized as compliant (C) or non-compliant (N). Three inertial measurement units (IMUs), placed on each participant’s forehead, sternum, and stretcher, yielded data on H-N motion. Outcomes were described in terms of H-N displacement and acceleration, including single- and multi-planar values, root mean square (RMS), and bouts of continuous motion above pre-determined thresholds. Data were analyzed to compare H-N motion by phase of prehospital care, as well as treatment type and patient behavior.

Results

Substantial single- and multi-plane H-N motion was observed among all participants. Maximum single-plane displacements were between 11.3 ± 3.0 degrees (rotation) and 19.0 ± 16.6 degrees (flexion-extension). Maximum multi-plane displacements averaged 31.2 ± 7.2 degrees (range: 7.2 to 82.1 degrees). Maximum multi-plane acceleration averaged 5.8 ± 1.4 m/s2 (range: 1.2 to 19.9 m/s2). There were no significant differences among participants between prehospital phase and treatment type. Non-compliant participants showed significantly more motion than compliant participants. Conclusion: Among actual patients, movement appears to be greater than previously recorded in simulation studies, and to be associated with patient behavior. Miniature IMUs are a feasible approach to field-based measurement of H-N kinematics in trauma patients. Future research should evaluate the effects of patient compliance, treatment, and phase of care using larger samples. Key words: spinal immobilization; cervical spine; cervical collar; long backboard

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 85.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.