Amniotic fluid index measurements in the second and third trimester and correlation to fetal biometric parameters – new reference based on a big retrospective data

, &
Pages 8176-8180 | Received 05 Jun 2021, Accepted 05 Aug 2021, Published online: 01 Sep 2021
 

Abstract

Introduction

Estimation of amniotic fluid volume (AFV) is part of routine obstetric sonography which reflects maternal–fetal circulation efficiency, fetal hemodynamic status, and a parameter for predicting adverse neonatal outcome. Fetal weight is positively correlated with AFV. Therefore, our objective is to provide a new nomogram of AFV indices and to evaluate the relation between AFV and fetal biometric parameters.

Materials and methods

Retrospective cohort study between 2011 and 2018, at a large tertiary medical center. Data were collected from medical charts of prenatal sonographic evaluation of normal pregnancies, including routine estimation of AFV by using amniotic fluid index (AFI). Generalized estimating equations model was used to study the association between AFI, gestational age and fetal biometric parameters. Centiles were calculated using the Generalized Additive Models for Location, Scale, and Shape model. Box-Cox-t distribution and smoothing splines were used.

Results

Analysis included 28,650 pregnancies. From 25 to 41 weeks gestation, the median and fifth percentile AFI gradually decreased from 174 (IQR 157–193) to 138 mm (IQR 107–173) and from 125 to 68 mm, respectively. The change in the 95th percentile was less significant, ranging around 230 mm throughout pregnancy. Multivariate regression analysis demonstrated a significant correlation between AFI and maternal body mass index (B = −0.147; CI = −0.27 to −0.02), gestational age (B = −11.8; CI = −12.5 to −11.4), estimated fetal weight (EFW) (B = 0.05; CI = 0.049–0.053) and abdominal circumference (AC) (B = 0.94; CI = 0.95–1). There was no correlation between AFI and other fetal biometric parameters.

Conclusions

We suggest new AFI indices of singleton pregnancies. We found a positive correlation between AFI and EFW and AC.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Data availability statement

All authors have a secured access to the study data. Data are available from the corresponding author on request.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.