174
Views
5
CrossRef citations to date
0
Altmetric
Original Articles

Performance of ophthalmic artery Doppler velocimetry in the complementary diagnosis of preeclampsia

ORCID Icon, , , , &
Pages 9078-9085 | Received 15 Aug 2021, Accepted 01 Dec 2021, Published online: 31 Jan 2022
 

Abstract

Objectives

To calculate the accuracy (A) and establish the best cutoff value for ophthalmic artery (OA) Doppler velocimetry indexes in patients diagnosed with preeclampsia (PE), compared with healthy pregnant women.

Methods

This prospective experimental study enrolled 268 women: 133 with PE and 135 healthy pregnant women. All patients were evaluated by OA Doppler sonography, bilaterally, to assess their pulsatility index (PI), resistance index (RI), peak systolic velocity (PVS), second peak systolic velocity (P2), end-diastolic velocity (EDV), and peak ratio (PR). Means were compared using Student’s T-test. Receiver Operating Characteristics (ROC) curve was used to establish the cutoff value and estimate the sensitivity (S), specificity (Sp), accuracy (A) of all variables, and a significance of 95% was adopted.

Results

ROC curve analysis showed that P2 and PR were superior to the other parameters for PE diagnosis. We tested two cutoff values: (1) using PR ≥0.70, obtained A: 88.72%, S: 81.95%, and Sp: 95.48% and (2) using PR ≥0.75, and A: 86.24%, S: 74.43%, and Sp: 99.24%. By adopting P2 ≥ 21.5 cm/s, we obtained A: 87.59%, S: 84.96%, and Sp: 90.22% and when the cutoff point was P2 ≥ 22 cm/s, there was a slight decrease in A to 86.46% and S to 81.20%, with Sp: 91.89.3%.

Conclusion

Ophthalmic artery Doppler demonstrated to be an effective and high-performance imaging method for the diagnosis of PE and the indexes P2 and PR demonstrated superior accuracy to the other Doppler parameters assessed. Higher performance occurred when the cutoff values with greater specificity were adopted, PR ≥ 0.75 and P2 ≥ 22 cm/s, considering that the proposed OA Doppler is to be a complementary method for preeclampsia.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.