140
Views
4
CrossRef citations to date
0
Altmetric
TECHNICAL NOTE

Influence of carbon monoxide leaks on the measurement error of total haemoglobin mass

, , , , , & show all
Pages 523-528 | Received 17 Jan 2011, Accepted 06 May 2011, Published online: 06 Jul 2011
 

Abstract

Total haemoglobin mass (Hbmass) can be assessed with low measurement error using carbon monoxide (CO) rebreathing. However, variability in measurement error of Hbmass has been reported across laboratories and it has previously been suggested that CO leaks contribute to this variability. As a result of employing a standardized leak monitoring procedure using two CO detectors, we were able to retrospectively examine the impact of CO leaks on Hbmass values from past test-retest studies in our laboratory using the optimized CO rebreathing method. Test-retest data were collected to determine measurement error, with subjects tested twice within 5 days. Test-retest data were placed into separate categories based on magnitude and duration of CO leak observed during one of the two tests. The No Leak category contained test-retest data in which no leak occurred during either test. The Minor Leak category contained test-retest data in which one of the tests had a CO leak of magnitude less than 30 ppm and less than 5 seconds duration, whereas the Major Leak category included test-retest data in which a leak greater than this magnitude or duration occurred. Measurement error was lowest in the No Leak category (1.9%; 95%CI: 1.6–2.3%; n = 56), approximately doubled in the Minor Leaks category (3.6%; 95%CI: 2.6–6.1%; n = 13), and dramatically increased in the Major Leaks category (9.3%; 95%CI: 6.3–17.6%; n = 10). We recommend careful monitoring of potential CO leaks using multiple detectors. To minimize measurement error, tests in which any CO leak is detected should be excluded.

Acknowledgements

This research was funded by a HQ AF/SGR grant and a USAF Academy Life Sciences Research Center grant. The views expressed are those of the authors and do not reflect the official policy or position of the United States Air Force, the Department of Defense, or the US Government.

Declaration of interest: The authors report no conflict of interest. The authors alone are responsible for the content and writing of the paper.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 200.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.