1,431
Views
17
CrossRef citations to date
0
Altmetric
Clinical Study

Effects of vitamin E-coated dialysis membranes on anemia, nutrition and dyslipidemia status in hemodialysis patients: a meta-analysis

, , &
Pages 398-407 | Received 06 Aug 2014, Accepted 09 Dec 2014, Published online: 14 Jan 2015

Figures & data

Figure 1. Flow diagram of study selection.

Figure 1. Flow diagram of study selection.

Table 1. Characteristic of included studies.

Figure 2. Risk of bias graph and bias summary: review authors’ judgements about each risk of bias item presented as percentages across all included studies and review authors’ judgements about each risk of bias item for each included study.

Figure 2. Risk of bias graph and bias summary: review authors’ judgements about each risk of bias item presented as percentages across all included studies and review authors’ judgements about each risk of bias item for each included study.

Figure 3. Forest plot of studies comparing the effect of vitamin E-coated dialyzer versus conventional dialyzer on HB level in hemodialysis patients.

Figure 3. Forest plot of studies comparing the effect of vitamin E-coated dialyzer versus conventional dialyzer on HB level in hemodialysis patients.

Figure 4. Forest plot of studies comparing the effect of vitamin E-coated dialyzer versus conventional dialyzer on EPO dose and EPO resistance index in hemodialysis patients.

Figure 4. Forest plot of studies comparing the effect of vitamin E-coated dialyzer versus conventional dialyzer on EPO dose and EPO resistance index in hemodialysis patients.

Figure 5. Forest plot of studies comparing the effect of vitamin E-coated dialyzer versus conventional dialyzer on serum Alb, IMT of the carotid artery and Kt/V levels in hemodialysis patients.

Figure 5. Forest plot of studies comparing the effect of vitamin E-coated dialyzer versus conventional dialyzer on serum Alb, IMT of the carotid artery and Kt/V levels in hemodialysis patients.

Figure 6. Forest plot of studies comparing the effect of vitamin E-coated dialyzer versus conventional dialyzer on lipid parameters in hemodialysis patients.

Figure 6. Forest plot of studies comparing the effect of vitamin E-coated dialyzer versus conventional dialyzer on lipid parameters in hemodialysis patients.

Table 2. Summary effect of vitamin E-coated dialyzer on maintenance hemodialysis patients.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.