14
Views
0
CrossRef citations to date
0
Altmetric
Original

Cosmetic results of lower midline abdominal incision: Donati stitches versus a continuous intracutaneous suture in a randomized clinical trial

, &
Pages 955-959 | Received 13 Jun 2005, Published online: 03 Aug 2009
 

Abstract

Background. The objective of this study was to compare the cosmetic outcome of two different closing techniques for lower midline abdominal incisions: a continuous intracutaneous suture versus interrupted Donati stitches.Methods. Eighty patients undergoing gynecological surgery through a lower midline abdominal incision were randomized. The cosmetic outcome of the scar was assessed by independent observers and the patients at 8 days and 4–6 months after the operation using visual analog scales and a validated scoring system for hypertrophy, width, color, and cross-hatching. Patients also completed a visual analog scale for postoperative pain on both occasions. The accumulated data were statistically evaluated using two-sided χ2, Student's t, or Mann–Whitney tests with a confidence interval of 95%. Results. Closing a lower midline abdominal laparotomy wound with an absorbable intracutaneous suture did not take more time than using Donati stitches. Laparotomy scores were only significantly better in the intracutaneous group at the first assessment, one week after the operation. The cosmetic visual analog scale scores by both independent observers and patients were slightly better in the intracutaneous group but the difference was not statistically significant. There was also no significant difference between visual analog scale scores for pain felt around the scar. Conclusions. This study shows that in the opinion of both independent observers and patients, scar cosmetics are not significantly different when using Donati skin sutures or an intracutaneous suture to close a lower midline laparotomy wound. The two methods do not differ either in time-consuming aspects or postoperative pain perception.

Acronyms
VAS=

visual analog scale

Acronyms
VAS=

visual analog scale

Log in via your institution

Log in to Taylor & Francis Online

There are no offers available at the current time.

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.