Ozone air levels adjacent to a dental ozone gas delivery system

, , &
Pages 324-330 | Received 09 May 2007, Published online: 02 Jul 2009
 

Abstract

Objective. Ozone (O3) has been suggested as an anti-microbial treatment in dentistry, with an ozone gas delivery system introduced for the treatment of fissure and root caries. The aim of this study was to investigate the sealing capacity of the novel delivery system and its re-suction capacity during accidental displacement of the cup at different stages of ozone delivery. Material and methods. Ozone leakage was studied in vitro after application on a flat metal surface and on buccal and occlusal tooth surfaces. An ozone analyzer was used to measure ozone gas concentrations adjacent to the delivering cups when adapted to the target surfaces during and after 10–20 s application cycles. The measured levels were compared with the background concentrations in the room. Measurements were performed 1) after complete ozone application cycles, 2) within the cycle before the start of the suction period, and 3) after displacements of the cup during the cycles. Results. Ozone air values varied between 8 and 166 µg·m−3 for the flat metal surface and between 0 and 108 µg·m−3 for the tooth surfaces. Ozone leakage levels were 7.6 µg·m−3 for the flat and 7.4 µg·m−3 and 5.6 µg·m−3 for the buccal and occlusal surfaces, respectively, and 5.2 µg·m−3 and 9.8 µg·m−3 for the premolar and molar surfaces, respectively. Cycles with displacement showed significantly higher leakage levels than continuous complete cycles (p=0.03). Conclusions. Ozone application cycles with displacements showed significantly higher leakage levels than continuous complete cycles. The largest ozone delivery cups showed the highest leakage values. A change in background levels was seen with similar change in adjacent ozone levels. The overall measured ozone leakage values were low after normally functioning delivery cycles and after repeated displacements. The delivery system can be considered safe.

Log in via your institution

Log in to Taylor & Francis Online

There are no offers available at the current time.

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.