189
Views
4
CrossRef citations to date
0
Altmetric
Original Articles

Telemetric intracranial pressure monitoring: our experience with 22 patients investigated for intracranial hypertension

, , , , , , & show all
Pages 430-437 | Received 12 Apr 2020, Accepted 05 Nov 2020, Published online: 02 Dec 2020
 

Abstract

Introduction

We present the application of the Raumedic® P-tel telemetric device that monitors Intracranial Pressure (ICP) over long periods, in 22 patients, with suspected intracranial hypertension.

Methods

A telemetric device (Raumedic®, Neurovent® P-tel) was surgically implanted in 22 patients aged between 21 and 65 years. Among the patients, the inconclusive diagnosis of benign intracranial hypertension was set in 10, the possible diagnosis of postoperative hydrocephalus in 3, and the possible diagnosis of aqueduct stenosis in 2. Additionally, shunt malfunction and Normal Pressure Hydrocephalus (NPH) were investigated in 1 and 3 patients, respectively. Finally, 3 patients presented ventricular dilatation of unknown origin. All the individuals underwent a 3-day ICP recording within the nursing unit. Three more recordings were obtained over a period of 2–6 months at the outpatient base.

Results

Analysis of the data excluded the diagnosis of intracranial hypertension in 12 patients. Elevated ICP values were confirmed in 10 patients. Subsequently, 7 of them underwent shunts’ implantation, while 2 refused further neurosurgical treatment and 1 was treated with acetazolamide. Additionally, 1 patient who demonstrated normal ICP values, thus confirmed with NPH, underwent VP shunt implantation, while another 2 with similar characteristics refused further surgery. In our series the overall clinical complication rate after P-tel implantation was insignificant.

Conclusions

The telemetric device is safely implanted via a rather simple procedure. In selected patients, it could provide long-term ICP recordings, which are necessary to confirm diagnosis and guide to the appropriate treatment.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 764.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.