1,167
Views
5
CrossRef citations to date
0
Altmetric
ORIGINAL ARTICLE

Contrast Medium Dose-to-GFR Ratio: A Measure of Systemic Exposure to Predict Contrast-Induced Nephropathy after Percutaneous Coronary Intervention

, , &
Pages 658-667 | Published online: 04 Aug 2009
 

Abstract

Background: The contrast medium (CM) dose-to-eGFR (estimated glomerular filtration rate) ratio has recently been advocated to express systemic exposure to CM in assessing the risk of contrast medium-induced nephropathy (CIN).

Purpose: To evaluate how CIN risk might vary with decreasing eGFR at fixed CM-dose/eGFR ratios and other CIN risk factors, and to find a relatively safe CM-dose/eGFR ratio.

Material and Methods: 391 patients underwent primary coronary angioplasty for ST-segment elevation acute myocardial infarction. CM dose (grams iodine; g I), eGFR (ml/min), and preprocedural CIN risk factors were entered into a multiple logistic regression model. From the established statistical model, the probability of CIN (≥44.2 µmol/l serum creatinine rise or oliguria/anuria) was calculated at various eGFR levels based on g-I/eGFR ratios of 1:2, 1:1, 2:1, and 3:1.

Results: At a g-I/eGFR ratio <1 the risk of CIN was 3%, while it was 25% at a g-I/eGFR ratio ≥1. Independent predictors of CIN were CM dose, eGFR, left ventricular ejection fraction (LVEF) and cardiogenic shock (ROC area =0.87). An estimated CIN risk of 10% would for example occur at a g-I/eGFR ratio of 1.5:1 in patients with 50% LVEF without shock. At a 1:2, 1:1, 2:1, and 3:1 g-I/eGFR ratio with 50% LVEF without shock, the CIN risk was about 2, 6, 18, and 30%, respectively, over a wide range of eGFR values (30–90 ml/min). At a 1:1 g-I/eGFR ratio with 50% LVEF+shock, 25% LVEF without shock, or 25% LVEF+shock, the CIN risk was 20, 55, and 80%, respectively.

Conclusion: Relating CM dose to eGFR appears to be an attractive pharmacotoxic model to assess CIN risk. At fixed CM-dose/eGFR ratios, CIN risk increased marginally with decreasing eGFR. Limiting the CM dose in g I numerically to the eGFR value in ml/min or less may be relatively safe with regard to CIN, unless multiple risk factors are present.

Log in via your institution

Log in to Taylor & Francis Online

There are no offers available at the current time.

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.