25
Views
0
CrossRef citations to date
0
Altmetric
Research Article

The Spiral of Tillaux: dead on accurate; a cadaveric study

, BA, , DO, , BA, , BAORCID Icon, , BA & , MD
Pages 85-90 | Published online: 06 May 2024
 

ABSTRACT

Introduction

The Spiral of Tillaux describes the historically accepted insertion distances of the medial rectus, inferior rectus, lateral rectus, and superior rectus from the limbus: 5.5 mm, 6.5 mm, 6.9 mm, and 7.7 mm, respectively. The corneal diameters are historically accepted to be 11.7 mm horizontally and 10.6 mm vertically in adults. We investigated the variability of the insertion distances of the extraocular rectus muscles from the limbus as well as the corneal diameters using eyes from human cadavers and compared our measurements to these historically accepted measurements.

Methods

A sample of 60 eyes were included. For each eye, a 360 peritomy was conducted and the conjunctiva bluntly dissected to view the sclera. Muscle hooks were utilized to isolate the extraocular rectus muscles. Calipers were used to measure the insertion distances of the rectus muscles as well as the corneal diameters.

Results

The mean rectus muscle insertions distances from the limbus were medial 5.28 mm, inferior 5.72 mm, lateral 6.40 mm, and superior 6.78 mm. These insertion distances were shorter than the historical benchmarks (p < .01). However, observed maximum distances of the rectus muscles were all greater than the historically accepted benchmarks, with the medial, inferior, lateral, and superior rectus muscles being 6.4 mm, 7.3 mm, 7.4 mm, and 7.8 m from the limbus, respectively. The mean width and height of the cornea were 11.7 mm and 10.7 mm, respectively, and similar to the expected ranges.

Conclusion

This study concludes that variability does exist from the historically accepted Spiral of Tillaux measurements. In addition, significant variation exists between male and female rectus muscle insertions. However, we did confirm that the rectus muscles followed the same spiral pattern described by the Spiral of Tillaux and concluded that the corneal diameters are consistent with previously accepted values.

Acknowledgements

We thank Dr. Beth Brainerd, PhD, Department of Anatomy, the Warren Alpert Medical School, for access to the anatomy laboratory and assistance in collecting demographic data.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Additional information

Funding

The author(s) reported there is no funding associated with the work featured in this article.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 442.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.