179
Views
12
CrossRef citations to date
0
Altmetric
Research Article

High-performance liquid chromatography (HPLC) determination of inosine, a potential biomarker for initial cardiac ischaemia, using isolated mouse hearts

, , , , &
Pages 449-459 | Received 17 Oct 2005, Published online: 08 Oct 2008
 

Abstract

Each year in the USA approximately 7–8 million patients with non-traumatic chest pain come to hospital emergency rooms. It is estimated that approximately 2–5% of these patients are experiencing cardiac ischaemia, but due to the shortcomings of the available testing methods they are incorrectly diagnosed and discharged without appropriate therapy having been provided. Preliminary data with a globally ischaemic mouse heart model has demonstrated that endogenous inosine might be a potential biomarker of initial cardiac ischaemia before cardiac tissue necrosis. A high-performance liquid chromatographic diode array detection (HPLC-DAD) method was utilized for the detection and quantification of inosine in Krebs–Henseleit (Krebs) buffer solution perfusing from surgically removed and isolated mouse hearts undergoing global cardiac ischaemia. A C18 column at a flow rate of 0.6 ml min−1 with an aqueous mobile phase of trifluoroacetic acid (0.05% trifluoroacetic acid in deionized water, pH 2.2, v/v) and methanol gradient was used for component separation. The assay detection limit for inosine in Krebs buffer solution was 500 ng ml−1 using a 100-µl neat injection. The HPLC results were used to determine total cardiac effluxed inosine into the Krebs effluent for each mouse during oxidative stress and compared with the per cent cardiac ventricular functional recovery rate to determine if a relationship exists amongst this cardiovascular parameter during periods of cardiac oxidative stress.

Acknowledgements

The authors would like to thank Dr Bill Gardner, Philip Morris USA, for his technical expertise using high-performance liquid chromatography-mass spectrometry (HPLC-MS) and Philip Morris USA for the use of high-performance liquid chromatographic diode array detection (HPLC-DAD) equipment for the analysis of Krebs samples. The authors also thank Mr Brian Berger for his technical assistance on initial work using isolated mouse hearts undergoing oxidative stress. Dr Lei Xi is supported by a grant from American Heart Association, National Center (No. 0530157N).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 527.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.