Cost-effectiveness of TYRX absorbable antibacterial envelope for prevention of cardiovascular implantable electronic device infection

, , , , , , , & show all
Pages 294-300 | Received 08 Aug 2017, Accepted 02 Nov 2017, Published online: 03 Jan 2018

Abstract

Aims: Infection is a major complication of cardiovascular implantable electronic device (CIED) therapy that usually requires device extraction and is associated with increased morbidity and mortality. The TYRX Antibacterial Envelope is a polypropylene mesh that stabilizes the CIED and elutes minocycline and rifampin to reduce the risk of post-operative infection.

Methods: A decision tree was developed to assess the cost-effectiveness of TYRX vs standard of care (SOC) following implantation of four CIED device types. The model was parameterized for a UK National Health Service perspective. Probabilities were derived from the literature. Resource use included drug acquisition and administration, hospitalization, adverse events, device extraction, and replacement. Incremental cost-effectiveness ratios (ICERs) were calculated from costs and quality-adjusted life-years (QALYs).

Results: Over a 12-month time horizon, TYRX was less costly and more effective than SOC when utilized in patients with an ICD or CRT-D. TYRX was associated with ICERs of £46,548 and £21,768 per QALY gained in patients with an IPG or CRT-P, respectively. TYRX was cost-effective at a £30,000 threshold at baseline probabilities of infection exceeding 1.65% (CRT-D), 1.95% (CRT-P), 1.87% (IPG), and 1.38% (ICD).

Limitations and conclusions: Device-specific infection rates for high-risk patients were not available in the literature and not used in this analysis, potentially under-estimating the impact of TYRX in certain devices. Nevertheless, TYRX is associated with a reduction in post-operative infection risk relative to SOC, resulting in reduced healthcare resource utilization at an initial cost. The ICERs are below the accepted willingness-to-pay thresholds used by UK decision-makers. TYRX, therefore, represents a cost-effective prevention option for CIED patients at high-risk of post-operative infection.

Introduction

Complications associated with cardiovascular implantable electronic devices (CIED) include infections and device migration or erosion. CIED-related infections are difficult to diagnose and treat, can be associated with significant morbidity and prolonged hospital stay, and carry a recommendation of complete device explantationCitation1,Citation2. Systemic infection associated with CIED can be life-threatening with all-cause mortality rates of up to 35% reported over follow-up periods of up to 5.5 yearsCitation1. Device explantation is a major procedure and carries a risk of mortality or serious complicationsCitation1,Citation3. Besides patient-related morbidity and mortality, management of CIED infections has considerable financial impact. The average hospital charge for a CIED infection in the US was estimated to be $146,000 in 2009Citation4, and the average cost of a CIED infection in the UK National Health Service (NHS) has been estimated at £30,958 (publication date 2014), taking into account extended hospital stay, device explantation, re-implantation, and antibiotic useCitation3.

Device infection occurs in 1–2% of CIED recipients overallCitation3,Citation4, and in 3–4% of high-risk patientsCitation5,Citation6. The number of cases is somewhat uncertain, but appears to be increasing due to the rising number of CIED implantations, proportionately increasing the use of CRT devices which entail a more complex implant procedure, and higher prevalence of comorbid conditions in CIED recipientsCitation1,Citation4. Given the high clinical and economic burden of CIED infections, prevention is of prime importanceCitation1.

The TYRX™ Absorbable Antibacterial Envelope (Medtronic plc, Mounds View, MN)Citation7 is a sterile, single-use surgical mesh envelope that houses the CIED generator when implanted into the pocket. A non-absorbable version of the envelope was previously available; however, this was discontinued following the launch of the absorbable envelope. It provides prophylaxis against infection by eluting the antibiotics rifampin and minocycline for a minimum of 7 days in the generator pocket environment before being fully absorbed by the body. It also helps to stabilize the device by lowering the risk of device migration. Efficacy of the envelope based on prospective randomized trials is yet to be reported, although this is currently under investigation in two clinical trials: the World-wide Randomized Antibiotic Envelope Infection Prevention Trial (WRAP-IT), a randomized, controlled trial comparing CIED infection rates and complications over a 12-month period for absorbable antibacterial envelopes vs no envelope (NCT02277990)Citation8; and in the Perioperative Antibiotic Therapy to Prevent Cardiac Implantable Electronic Device Infections (ENVELOPE) trial (NCT02809131)Citation9. However, effectiveness of the TYRX Antibacterial Envelope has been studied in a series of observational trials among patients at high-risk for CIED infectionCitation6,Citation10–13 with the first generation of non-absorbable envelopes and more recently with the absorbable envelopeCitation10. In these studies, patients with TYRX Envelopes experienced a reduction of 69–100% in CIED infections compared to patients who underwent CIED implantation without the envelope.

This paper describes a cost-effectiveness model developed to assess the cost implications and health outcomes associated with TYRX Absorbable Antibacterial Envelopes vs current standard of care (SOC) in the prevention of infection post-CIED implantation from the NHS perspective. The paper presents the economic value of utilizing TYRX, compared with an infection control protocol with no Envelope, for patients undergoing a de novo or replacement implantation with a cardiac resynchronization therapy defibrillator (CRT-D), cardiac resynchronization therapy pacemaker (CRT-P), implantable pulse generator (IPG), or implantable cardioverter defibrillator (ICD) in both the short and longer term.

Methods

Model structure

Given the short-term nature of the decision problem (i.e. the short-term impact of the Envelope on the risk of infection), a decision tree with a time horizon of 1 year was selected as the appropriate model structure. However, best practice in cost-effectiveness modelling is to establish the costs and benefits associated with an intervention for the period of time over which these are expected to differ. As such, following on from the decision tree, patients were allocated long-term costs and benefits corresponding to their status at 12 months. This ensured that any differences in lifetime costs and benefits due to mortality differences between treatments were captured. The decision tree model () was developed in Microsoft Excel (Microsoft Corporation, Redmond, WA) to assess the cost-effectiveness of TYRX Absorbable Antibacterial Envelopes vs SOC infection prophylaxis for each of the CIEDs of interest (CRT-D,CRT-P,IPG, ICD for patients at “high-risk” of infection, as well as for those at lower risk of infection (“all-comers”).

Figure 1. Decision tree analysis of using TYRX for the prevention of infection post-CIED implantation.

Figure 1. Decision tree analysis of using TYRX for the prevention of infection post-CIED implantation.

Each event following the initial procedure was characterized by a node that occurred with a given probability, and each branch represented a mutually exclusive pathway. The total costs and pay-offs associated with either treatment option were calculated by multiplying the pathway probabilities by the corresponding costs and outcomes and summing the expected costs and pay-offs. In the absence of literature on sub-group-specific data relating to events other than CIED infections, these were assumed not to differ across treatments or risk groups. The pathway probabilities, therefore, differed between treatment arms and sub-groups only to the extent that they were conditional on the initial infection risk.

SOC was defined as one course of pre-operative antibiotic prophylaxis only. In addition, patients in the TYRX arm received the envelope during the procedure. Following the procedure, all patients were at risk of experiencing a CIED infection ().

Model inputs

The tables of model inputs are given in the Supplementary material.

Probability of infection

Infection rates associated with SOC for “high-risk” patients were obtained from two prospective analysesCitation5 and four retrospective observational studies of TYRXCitation5,Citation6,Citation11–13. For the “all-comers” category, probabilities of infection associated with SOC were obtained from the Shariff et al.Citation12 study. Absolute probabilities of infection for TYRX were also available from these studies. Rather than use these values in the model directly, which would mean they were independent of the probability of infection for SOC, a relative risk associated with the use of TYRX was calculated and applied to the probability of infection with SOC. An assumption was made that the relative risk would apply consistently across all risk groups, with the difference in infection rates driven only by the difference in the baseline risk (probability of infection with SOC). As such, the relative risk was determined by pooling the total populations (N) and number experiencing an infection (n) across all studies for SOC and independently for TYRX. The data and calculation method used to derive this mean relative risk value (0.163) are reported in the Supplementary material. Applying the relative risk to the baseline probability of infection with SOC for each study/pooled analysis provided estimates of the probability of infection for TYRX. Device-specific infection rates for the high-risk population were not reported in the literature, and, as such, baseline infection rates were assumed to be equivalent across device types. Clinical input from a UK expert was sought to validate data inputs and assumptions.

Infection management

Complete removal of the device and leads is recommended for major CIED infectionsCitation1,Citation14. An estimated 3–15% of patients refuse or are considered medically unfit for device extractionCitation1. An estimate of 5% was used in the model on the basis of clinical expert opinion. These patients received only non-surgical infection management and did not undergo, or accrue the costs of, extraction surgery. Of the 95% of patients undergoing device extraction, 95% were assumed to have had complete extractionCitation15. This was validated by clinical expert opinion. Of these, 80% were assumed to receive re-implantation, and the remaining 20% were not re-implanted. Of the 5% assumed to experience an incomplete extraction of the device, we assumed no replacement device was required. These inputs were based on clinical expert opinion.

Mortality

Among patients with a major CIED infection, mortality within the first 12 months was assumed not to differ between patients who received a replacement device and those who did not; however, life expectancy for those who survived to 12 months was assumed to differ between these patients. The mortality rates for patients without a CIED infection and patients who experience a complete extraction following a CIED infection were obtained from the Shariff et al.Citation12 study. Mortality rates in patients who experienced a partial extraction or in whom extraction was not undertaken were assumed to be double the rate associated with a complete extractionCitation16. The probabilities of death at 12 months used in the decision tree were: no infection = 0.064; complete extraction = 0.211; partial/no extraction = 0.422.

Costs and resource use

Antibiotic costs: Patients in the TYRX arm were assumed to receive the Envelope at a one-off cost of £719.00 (prices in 2015 GBP). In addition to the antibiotics eluted by the Envelope (minocycline and rifampicin) all patients who received a TYRX Envelope in the Shariff et al.Citation12 study received additional prophylactic antibiotics. In the absence of detailed information on the antibiotics used, usage was assumed to be equivalent to that in patients who did not receive the Envelope. Patients in both treatment arms, hence, incurred the cost of one course of prophylactic antibiotics. The mix and costs of antibiotics used are presented in the Supplementary material.

Infection and adverse event costs: The total number of cardiac ward bed days and ICU bed days for patients experiencing a CIED infection, and the associated cost per day, were obtained from Ahsan et al.Citation3 and adjusted to 2015 costs. As a sensitivity analysis, the cost per day in the cardiac ward was increased by 10% to assess the potential impact of additional costs including laboratory tests, GP visits, and X-rays. A proportion of patients experience a re-infection within 12 months (see Supplementary Table S11), with the proportions dependent on whether an extraction was undertaken successfully or not. Locations of care, daily costs, and length of stay for patients experiencing CIED infection are shown in the Supplementary Table S10.

Cost of device extraction and replacement: The cost of extraction surgery was assigned to all patients with an infection for whom extraction surgery was undertaken, irrespective of success. In addition, patients who received a replacement device following complete extraction were allocated the cost for replacement surgery and for the replacement device. The costs of device extraction and replacement were taken from UK tariffs and are shown in the Supplementary material.

Health-related quality-of-life

Health-related quality-of-life (HRQoL) was captured using utilities. Utility data were sourced from the National Institute for Health and Care Excellence (NICE) technology appraisal (TA) 314 Guidance assessment report, which evaluated ICDs vs optimal pharmacological therapy (OPT) in the treatment of arrhythmias and CRT-Ds or CRT-Ps in addition to OPT vs OPT in the treatment of heart failureCitation17. A baseline utility was assigned to all patients on entering the model according to the device received (0.73 for IPG and 0.70 for the other device types).

A utility decrement of 0.025 was applied to the baseline for all patients who experienced a major CIED infection, with an additional decrement of 0.0125 for patients who experienced extraction surgery. These values were based on decrements for infection (0.10) and surgery (0.05) sourced from the NICE TA 314 Guidance assessment reportCitation17. The values from the report were re-scaled to represent a 3-monthly decrement to align with clinical expert opinion that the HRQoL impact of infection and extraction surgery would last for 3 months. In addition, patients who experienced a re-infection were assigned a further utility decrement equal to the decrement associated with an initial infection (0.025).

Estimation of long-term costs and benefits

An additional one-off cost was allocated to all patients who survived to 12 months to represent the expected costs over their remaining lifetime. These were sourced from the NICE TA 314 Guidance Assessment ReportCitation17. The allocated lifetime costs were based on initial device implanted, reflecting the different ongoing costs associated with each, for those who either do not need or who successfully receive a replacement device (i.e. nodes A and G). Those who require but do not receive a successful replacement (i.e. nodes C, E, and H) were assigned lower post-12-month costs reflecting both their lower life expectancy and the lack of ongoing upkeep of the device. These cost estimates, which include medication, device implantation, device-related complications and maintenance, hospitalization due to heart failure or arrhythmia, and transplantation, are presented in the Supplementary material.

In order to present a lifetime perspective, a one-off QALY estimate was allocated to all patients who survived to 12 months to represent the expected utility over the remaining lifetime for survivors. Mean post-12-month utility and life expectancy estimates were combined to derive the one-off QALY estimate.

Those either not requiring or successfully receiving a replacement CIED (i.e. nodes A and G) are expected to have a longer life expectancy than those requiring but not receiving a successful replacement (i.e. nodes C, E, and H). Estimates of life expectancy and utility were obtained from the economic analysis of ICDs, CRT-Ps, and CRT-Ds, in addition to OPT vs OPT alone described in NICE TA 314Citation17. IPG patients were assumed to accrue the same life expectancy as CRT-P patients. One year was subtracted from the life expectancy estimates to avoid double-counting of the first-year horizon of the decision tree.

Utility estimates for CRT-D, CRT-P, and ICD were estimated from the ratio of predicted quality adjusted life years (QALYs) to predicted life-years from the base case results of the economic evaluation described in the NICE TA 314 assessment reportCitation17. The utility estimates for IPG patients with or without a device were identified in a literature review described in the NICE guidance 324 assessment report for patients with a single-chamber atrial or dual-chamber pacemaker, and for bradycardia patients with heart failure, respectivelyCitation18,Citation19.

Analysis

Analyses were conducted from the perspective of the UK NHS. Results for the “high-risk” population for the four device types (CRT-D, CRT-P, IPG, and ICD) are presented below, the results for the “all-comers” population are presented in the Supplementary material. Results are also presented for a mix of device types. The proportion of patients receiving each device was sourced from the Mittal et al.Citation6 study. These data are presented in the Supplementary material.

Benefit is expressed as QALYs and the primary outcome measure from the economic model is an incremental cost-effectiveness ratio (ICER) which represents the ratio of incremental costs and incremental benefits associated with use of the Envelope compared to SOC. Key clinical outcomes of interest were the proportion of patients who survived to 12 months without experiencing an infection and with device extraction avoided (defined as complete or partial extraction). Other clinical outcomes of interest were fatalities and hospitalizations avoided.

Deterministic scenario analyses were undertaken to explore the impact of changes to individual parameters on the base case cost-effectiveness results. The scenarios that were explored included alternative treatment effects (via the use of different data sources), alterations to the device replacement rate, varying the assumption regarding the survival time for those who died during the initial 12 months, and variations to the cost of extraction surgery and in-patient care. Threshold analyses were also conducted on the baseline probability of infection.

Probabilistic sensitivity analyses (10,000 Monte Carlo simulations) were conducted to propagate the uncertainty in the individual parameters. Beta distributions were assigned to probabilities based on the number of events and the total sample (N). Where the number of events and total sample (N) were unknown, a standard error of 10% was assigned to probabilities and a beta distribution fit to these data through the method of moments. Utility values were also assigned beta distributions by adopting this approach. Costs and resource use frequencies were assigned a standard error of 10%, where a measure of uncertainty was not reported alongside the mean estimate. These were assigned gamma distributions based on the method of moments.

Results

The predicted short-term clinical outcomes arising from the modeling for the “high-risk” population are presented in . As baseline infection rates were assumed to be equivalent across device types, these clinical outcomes are independent of device type. TYRX decreased the absolute rate of CIED infection relative to SOC (–2.9%). In addition, the absolute rate of survival to 12 months without a CIED infection increased with use of TYRX relative to SOC (+2.8%). Use of TYRX was also associated with a reduced probability of device extraction, hospitalization, and mortality (–84.4%, –83.6%, and –7.1%, respectively). Twenty-two patients would need to be treated with TYRX to avoid one hospitalization and 37 to avoid a device explantation.

Table 1. Predicted clinical outcomes, 12-month time horizon.

presents cost-effectiveness results over the 12-month time horizon stratified by device type. TYRX was less costly and more effective than SOC when used in patients with an ICD or CRT-D device. For patients with an IPG or CRT-P device, TYRX was associated with an increase in cost and a modest increase in QALYs, generating ICERs of £46,548 and £21,768 per QALY gained, respectively. As the same baseline infection rate is applied across device types, the differences in ICERs across device type are driven by the differences in costs. For the mixed device analysis, TYRX was associated with no incremental cost (£0) and was more effective (+0.004 QALYs) than SOC, probably due to the high proportion of the population receiving an ICD or CRT-D device.

Table 2. Cost-effectiveness results (12-month time horizon).

The results from the scenario analyses for the 12-month time horizon are presented in . TYRX remained dominant in a number of scenarios using a 12-month time horizon, and the ICER associated with TYRX was most sensitive to the choice of baseline infection rate associated with SOC.

Table 3. Scenario analyses by device (12-month time horizon).

The results from the threshold analyses are presented in . Adopting a lifetime time horizon, TYRX is less costly and more effective (dominant) than SOC in patients with a CRT-D at baseline probabilities of infection exceeding 4.52% and is no longer cost-effective at a £30,000 threshold at a baseline probability below 1.65%. Similarly, TYRX dominates SOC in patients with CRT-P, IPG, and ICD devices at baseline probabilities of infection exceeding 5.71%, 7.69%, and 4.35% for each device, respectively. TYRX becomes cost-ineffective at a willingness-to-pay threshold exceeding £30,000, with probabilities of infection below 1.95%, 1.87%, and 1.38% for each device, respectively.

Table 4. Threshold analysis on baseline probability of infection.

Discussion

Precise estimates of incidence of CIED infections in the UK are lacking. However, the number of device implant procedures is increasing. The increasing number of procedures means that the observed infection rate is likely to rise, with an associated burden both on patients and on healthcare resource use in the UK NHSCitation1.

The study reported here represents the first attempt to quantify the lifetime impact of using a TYRX Absorbable Antibacterial Envelope, in addition to standard infection control protocols, on healthcare resource use, costs, and patient-centred outcomes. Particular emphasis was placed on the sub-group of CIED patients who would conventionally be considered at “high-risk” of infection. In our modeling, 3.2% of “high-risk” patients receiving SOC infection prophylaxis were predicted to require a CIED extraction procedure (partial or complete) within the first year of usage, and 5.5% were predicted to be hospitalized due to re-infection or device extraction within the first 12 months. In all, 90.5% of “high-risk” patients using SOC were estimated not to experience a CIED infection and to survive to 12 months.

Patients using TYRX, in addition to SOC, were predicted to have a decreased likelihood of experiencing a CIED infection and a reduction in the probability of experiencing either a CIED extraction procedure or a hospitalization within 12 months of initial device implantation. These benefits were ultimately driven by the derived infection relative risk estimate for TYRX compared to SOC (0.163). Such reductions would have a positive impact on clinical practice.

At cost-effectiveness thresholds conventionally used in UK device-related reimbursement decisions (between £20,000–£30,000 per QALY gained)Citation16,Citation20–22, TYRX represents good value for money. At a 12-month time horizon, TYRX was also less costly and more effective than SOC in patients with a CRT-D or ICD device.

A range of scenario/sensitivity analyses were undertaken, and the model was shown to be generally robust to all changes. The exception to this was the choice of source for the baseline infection rate, where alternative sources resulted in some instances where TYRX was cost-saving (the dominant option) and others where the ICER increased beyond £20,000 per QALY gained. The threshold analyses indicated that TYRX dominated SOC at baseline probabilities of infection exceeding 7.69% for all device types, whereas TYRX would be considered cost-effective at a willingness-to-pay threshold of £30,000 when used in any device at a baseline probability of infection exceeding 1.95%. No ICERs in excess of £30,000 per QALY gained were generated by the scenario analyses when using a lifetime time horizon and TYRX remained the dominant comparator in a number of scenarios when a 12-month time horizon was adopted.

One of the limitations of the current model is the absence of device-specific data for infection rates and mortality rates. Moreover, the current model is informed by data reported in observational studies due to the lack of prospective randomized trials in this disease area. The WRAP-ITCitation8 or ENVELOPE studyCitation9 may provide these data to populate the model. It was necessary to make a number of assumptions in the model including those around the proportion of patients experiencing a successful/partial extraction and device replacement following infection, baseline infection rates across device types, the use of antibiotics in those receiving TYRX, and the impact of infection on the utility of the patient. The results of the sensitivity analyses, however, indicate that the model is robust to changes in these assumptions.

Overall, our study findings, based on current knowledge and evidence available, suggest that TYRX is a cost-effective treatment option for reducing post-surgical infection risk when used in conjunction with all CIEDs.

Transparency

Declaration of funding

Funding for the analysis and publication charges for this article was provided by Medtronic.

Declaration of financial/other relationships

MRS has received honoraria/consulting fees from Medtronic, Spectranetics, and Boston Scientific (all less than US$10K) and a research grant from Medtronic. DJW has received honoraria from Boston Scientific, Medtronic, and St. Jude Medical and a research grant from Boston Scientific for an investigator initiated study. ELE, BB, and SE are employees of Medtronic. JME peer reviewers on this manuscript have no relevant financial or other relationships to disclose.

Supplemental material

Supplemental Material

Download MS Word (146.8 KB)

References

  • Sandoe JA, Barlow G, Chambers JB, et al. Guidelines for the diagnosis, prevention and management of implantable cardiac electronic device infection. Report of a joint Working Party project on behalf of the British Society for Antimicrobial Chemotherapy (BSAC, host organization), British Heart Rhythm Society (BHRS), British Cardiovascular Society (BCS), British Heart Valve Society (BHVS) and British Society for Echocardiography (BSE). J Antimicrob Chemo 2015;70:325-59
  • Sohail MR, Henrikson CA, Braid-Forbes MJ, et al. Mortality and cost associated with cardiovascular implantable electronic device infections. Arch Intern Med 2011;171:1821-8
  • Ahsan SY, Saberwal B, Lambiase PD, et al. A simple infection-control protocol to reduce serious cardiac device infections. Europace 2014;16:1482-9
  • Greenspon AJ, Patel JD, Lau E, et al. 16-Year Trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008. J Am Coll Cardiol 2011;58:6
  • Kolek MJ, Patel NJ, Clair WK, et al. Efficacy of a bio-absorbable antibacterial envelope to prevent cardiac implantable electronic device infections in high-risk subjects. J Cardiovasc Electrophysiol 2015;26:1111-16
  • Mittal S, Shaw RE, Michel K, et al. Cardiac implantable electronic device infections: incidence, risk factors, and the effect of the AigisRx antibacterial envelope. Heart Rhythm 2014;11:595-601
  • Huntingdon Life Sciences Study TR-2013-001, data on file with Medtronic, plc
  • World-wide Randomized Antibiotic Envelope Infection Prevention Trial (WRAP-IT): ClinicalTrials.gov 2015 [NCT02277990] https://clinicaltrials.gov/ct2/show/NCT02277990?term=NCT02277990&rank=1
  • Perioperative Antibiotic Therapy to Prevent Cardiac Implantable Electronic Device Infections (ENVELOPE): ClinicalTrials.gov 2017 (NCT02809131) [13] https://clinicaltrials.gov/ct2/show/NCT02809131?term=NCT02809131&rank=1
  • Bloom HL, Constantin L, Dan D, et al. Implantation success and infection in cardiovascular implantable electronic device procedures utilizing an antibacterial envelope. Pacing Clin Electrophysiol 2011;34:133-42
  • Kolek MJ, Dresen WF, Wells QS, et al. Use of an antibacterial envelope is associated with reduced cardiac implantable electronic device infections in high-risk patients. Pacing Clin Electrophysiol 2013;36:354-61
  • Shariff N, Eby E, Adelstein E, et al. Health and economic outcomes associated with use of an antimicrobial envelope as a standard of care for cardiac implantable electronic device implantation. J Cardiovasc Electrophysiol 2015;26:783-9
  • Henrikson CA, Sohail MR, Acosta H, et al. Antibacterial envelope is associated with low infection rates after implantable cardioverterdefibrillator and cardiac resynchronization therapy device replacement. J Am Coll Cardiol EP 2017;10:1158-1167 http://www.sciencedirect.com/science/article/pii/S2405500X17302505
  • Baddour LM, Epstein AE, Erickson CC, et al. Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association. Circulation 2010;121:458-77
  • Bongiorni MG, Marinskis G, Lip GY, et al. How European centres diagnose, treat, and prevent CIED infections: results of a European Heart Rhythm Association survey. Europace 2012;14:1666-9
  • Sohail MR, Uslan DZ, Khan AH, et al. Infective endocarditis complicating permanent pacemaker and implantable cardioverter-defibrillator infection. Mayo Clin Proc 2008;83:46-53
  • National Institute for Health and Care Excellence (NICE). Implantable cardioverter defibrillators for the treatment of arrhythmias and cardiac resynchronisation therapy for the treatment of heart failure (review of TA95 and TA120) Assessment Report. NICE; 2013; https://www.nice.org.uk/guidance/ta314/documents/arrythmias-icds-heart-failure-cardiac-resynchronisation-assessment-report2
  • Fleischmann KE, Orav EJ, Lamas GA, et al. Pacemaker implantation and quality of life in the Mode Selection Trial (MOST). Heart Rhythm 2006;3:653-9
  • Lopez-Jimenez F, Goldman L, Orav EJ, et al. Health values before and after pacemaker implantation. Am Heart J 2002;144:687-92
  • National Institute for Health and Care Excellence (NICE). Implantable cardioverter defibrillators for arrhythmias, TA 95UK. NICE; 2006; https://www.nice.org.uk/guidance/ta95
  • National Institute for Health and Care Excellence (NICE). Cardiac resynchronisation therapy for the treatment of heart failure, TA 120UK. NICE: 2007; https://www.nice.org.uk/guidance/ta120
  • Claxton K, Martin S, Soares M, et al. Methods for the estimation of the National Institute for Health and Care Excellence cost-effectiveness threshold. Health Technol Assess (Winchester, England) 2015;19:1-503,v–vi

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.