Reducing post-extubation failure rates in very preterm infants: is BiPAP better than CPAP?

, , , , , & show all
Pages 1272-1277 | Received 21 Dec 2019, Accepted 24 Mar 2020, Published online: 07 Apr 2020
 

Abstract

Background and Aim

Continuous positive airway pressure (CPAP) is currently used in neonates after mechanical ventilation though it may occasionally be associated with air leaks syndromes or it may fail to support the baby. The pressure difference offered by bilevel continuous positive distending pressure (BiPAP) respect to CPAP may be an advantage to the spontaneously breathing patient. In this study, we compared the efficacy of CPAP and BiPAP in the firstweek post-extubation in a series of very preterm infants.

Methods

Inborn neonates less than 30 weeks of gestational age who were intubated shortly after birth from January 2011 to December 2017 were enrolled in a retrospective study. The attending clinician assessed the patients for non-invasive respiratory support readiness and allocated them to CPAP (PEEP 4–6 cmH2O) or BiPAP (PEEP 4–5 cmH2O, rate 10–40; Thigh 0.7–1.2; upper-pressure level 8–10 cmH2O). Both techniques were compared for preventing extubation failure within 7 days from extubation as defined per local protocol (primary outcome). Secondary outcomes were: definitive failure of extubation, pneumothorax during non-invasive respiratory support, periventricular leukomalacia, bronchopulmonary dysplasia, sepsis, patent ductus arteriosus and retinopathy of prematurity at discharge.

Results

We enrolled 134 neonates; the CPAP group included 89 babies while 45 received BiPAP. Patients did not differ for their general characteristics (EG, antenatal steroids, incidence of SGA, maternal hypertension, surfactant replacement therapy). Short term extubation failure was significantly higher in the former group (23/89 in CPAP vs 5/45 in BiPAP; p = .005). No infant developed air leak syndrome. Secondary outcomes were comparable between groups. Multivariate analysis showed that on the whole population the extubation failure was correlated to the insurgence of late-onset sepsis.

Conclusion

BiPAP safely reduced early extubation failure compared to CPAP in our cohort of very preterm neonates within 7 days from extubation.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.