243
Views
0
CrossRef citations to date
0
Altmetric
Original Articles

Neonatal blood pressure before and after delayed umbilical cord clamping

, , &
Pages 5260-5264 | Received 05 Oct 2020, Accepted 12 Jan 2021, Published online: 21 Jan 2021
 

Abstract

Objective

To describe values of blood pressure (BP) before and after delayed cord clamping (DCC) in healthy term neonates born to low risk pregnancies, examine differences in the temporal patterns of BP during this transition, and assess potential correlation of these parameters with maternal and perinatal clinical and demographic variables.

Methods

Prospective observational study of term infants eligible for DCC born vaginally from uncomplicated pregnancies. Neonatal BP was estimated noninvasively before DCC, at 30 min and 24 h of life. Median, minimum, maximum, mean and standard deviation, as well as percentiles for BP values were calculated. Pearson correlation assessed the correlation between demographic and clinical variables and BP measurements. Spearman correlation studied the association between BP parameters prior to DCC and Apgar scores. Repeated measures ANOVA and Tukey post hoc analyses were used to compare BP measurements over time. A p-value of <.05 was considered significant.

Results

A total of 54 patients were included. Mean neonatal birthweight was 3185 g and gestational age 39/3 weeks. The mean values for the systolic, diastolic, and mean BP prior to DCC were 97 ± 24.9 mmHg, 58 ± 21.9 mmHg and 67 ± 27.7 mmHg respectively. A statistically significant difference was detected when comparing BP values obtained before DCC with those measured afterwards (). A positive correlation was found between SBP and MAP prior to DCC and Apgar scores at 1 min.

Figure 1. Repeated measures ANOVA for SBP, DBP, and MAP distribution over time.

Figure 1. Repeated measures ANOVA for SBP, DBP, and MAP distribution over time.

Conclusion

We describe novel values of BP before DCC in healthy term infants following vaginal delivery. Data suggest that neonates whose cord is clamped in a delayed fashion experience an increase blood pressures immediately after birth, followed by a significant drop within 30 min to levels that remain unchanged at 24 h of life. BP values obtained after DCC in our study are similar to those found by previous authors. Further studies are needed to determine the clinical significance of these findings and assess the potential of BP prior to DCC to evaluate immediate postnatal adaptation.

Limitations

Results generalizability may have been limited by varying degrees of neonatal resuscitation, inability to perform more than one measurement before cord clamping ensued, as well as an unequal distribution of self-reported race in our cohort. Also, noninvasive BP estimates have proven less accurate that invasive methods. Finally, our cohort was comprised by a relatively small sample and larger studies will be required to corroborate our findings.

Acknowledgement

We would like to thank our colleagues including physician, nurses, OB techs and other healthcare personnel in our department without whom this project could not have been done and all patients who agreed to participate in our study.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.