146
Views
0
CrossRef citations to date
0
Altmetric
Review

Current development and clinical applications of artificial anal sphincter

, , &
Pages 537-548 | Received 23 Jul 2021, Accepted 24 May 2023, Published online: 30 May 2023
 

ABSTRACT

Introduction

Fecal incontinence is a common chronic disease, which not only brings inconvenience to the lives of patients, but also causes great psychological harm to patients. Artificial anal sphincter is an innovative method that may treat fecal incontinence, and now has been clinically applied.

Areas covered

This article will review recent developments in mechanisms and clinical applications of artificial anal sphincter. The current results of clinical trials show that the implantation of artificial sphincter will cause morphological changes of surrounding tissues, and related biomechanical imbalance will lead to the loss of effectiveness of the device and various complications. In terms of safety, postoperative patients suffer from various complications such as infection, corrosion, tissue ischemia, mechanical failure, and difficulty in emptying. In terms of effectiveness, there is currently no long-term research data to prove that the implanted device can maintain a long-term functional state.

Expert opinion

The key issue for the safety and effectiveness of implantable devices is the biomechanical compatibility of implantable devices was proposed. Based on the superelasticity of shape memory alloy, this article proposes a new type of constant force artificial sphincter device, which provides a new direction for solving the clinical application of artificial anal sphincter.

Article highlights

  • In terms of long-term effectiveness, there is currently no long-term research data to prove that the implanted device can maintain a long-term functional state.

  • The key issue for the safety and effectiveness of implantable devices is the biomechanical compatibility of implantable devices.

  • The artificial anal sphincter embedded with constant force element may adapt to changes in the tissue morphology around the implant device, improve the biomechanical compatibility of the implant device, which provides a possibility to solve its clinical key technical problems.

Declaration of interest

The authors have no other relevant affiliations or financial involvement with any organization or entity with a financial interest in or financial conflict with the subject matter or materials discussed in the manuscript apart from those disclosed.

Declaration of interest

Peer reviewers on this manuscript have no relevant financial relationships or otherwise to disclose.

Additional information

Funding

This research was based on the project of National Natural Science Foundation of China (Project No. 31900944).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 99.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 570.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.