Pulse-lavage washing is an effective method for defatting of morselized allograft bone in the operating theater

, , , &
Pages 94-97 | Received 03 Mar 2007, Accepted 29 Jul 2007, Published online: 08 Jul 2009

Abstract

Background and purpose Incorporation of fresh-frozen allograft bone and safety aspects associated with this procedure can be improved by removing blood and lipids from the bone. We investigated in a quantitative manner how efficient pulse lavage might be for removal of adipose tissue from morselized allograft bone.

Methods Depending on the study, the washing was performed with an average of 0.8 L or 1.6 L of sterile saline at room temperature. Fat content of the morselized bone samples was determined using hexane elution. The efficiency of pulse lavage alone was compared with that after an additional wash in 12 L of warm water (55°C). Unprocessed controls were also included for comparison.

Results Pulse lavage with 0.8 L saline alone removed 80% of the fat from the bone, whereas 95% of the fat was removed when washing was performed with 1.6 L of saline. The cleansing efficacy was improved further when an additional wash with warm water was used.

Interpretation Our results indicate that pulse-lavage washing alone at room temperature is an effective method for defatting of morselized allograft bone, but an additional wash with warm water improves the cleansing efficiency. Pulse lavage is easily available and simple to use in the operating theater.

The use of allogenic bone in orthopedic surgery has increased steadily in recent years. The main source of allograft bone is femoral heads harvested from living donors during primary hip arthroplasties (Grieb et al. Citation2005, Yates et al. Citation2005). The transmission of viral diseases through transplantation of allografts has been a major concern (Tomford Citation1995, Aspenberg Citation1998). Most of the processing methods have been directed toward ensuring the safety of the patient by minimizing virus transmission (Grieb et al. Citation2005). The risk of infection is directly related to the amount of blood in the graft (Tomford Citation1995). It has been demonstrated that the risk of transmission of both HIV and HCV can be significantly reduced by removing blood and marrow from the bone (Tomford Citation1995, Yates et al Citation2005).

In addition, lipid extraction may increase the incorporation of frozen bone allografts and improve cup stability in impaction grafting (Thoren et al. Citation1995, Ullmark Citation2000, van der Donk et al. Citation2003, Arts et al. Citation2006). Pulse-lavage washing removes lipids and blood from morselized bone (Hirn Citation2001) and lowers the bacterial count in the graft (Hirn et al. Citation2004). Thus, it has been recommended that washing of morselized allograft bones in the operating theater should be done before transplantation. We evaluated in a quantitative manner how effectively pulse-lavage washing can remove lipids from morselized bone.

Material and methods

The grafts were obtained from the tissue bank of Tampere University Hospital. For the primary study, 5 condyles around the knee were harvested from 3 donors: 4 femoral condyles of 2 distal femurs and 1 proximal tibia. For the main study, 10 femoral heads from 10 living donors were selected. The femoral heads were retrieved in arthroplasty operations. Each of the donors was screened to be virus-negative according to the standards of the European Association of Tissue Banks (EATB and EAMST Citation1997). The condyles tested negative by bacteriological screening but femoral heads were rejected for different reasons, including positive bacterial culture. All bones were stored at −75°C before selection. Each of them was almost 5 years old. The bone grafts were cleaned free of remnants of chondral and soft tissue and then morselized separately using a bone mill (Howex, Gävle, Sweden). A standard 2-mm blade was used. This blade produced chips with a volume range of 0.3 x 0.3 x 0.3 mm (0.027 mm3) to 2 x 4 x 15 mm (120 mm3) as measured using a ruler. Condyles around the knee were morselized without cortical bone of the diaphysis. Femoral heads were ground with the cortical bone left in the neck of the femur.

Altogether, there were 15 morselized samples: 5 condyles for the primary study and 10 femoral heads for the main study. Each of these morselized samples was divided into 3 groups. The first group was left as an unprocessed control. The second group was washed by pulse lavage with physiological saline at room temperature. In the primary study, approximately 0.8 L of physiological saline was used per sample. In the main femoral head study, the amount of saline was doubled to 1.6 L per sample in order to determine whether increasing the amount of saline would improve the results. The pulse- lavage washing was done as previously described (Hirn Citation2001). Briefly, the morselized chips were washed by placing them in a sieve, where the material was spread out in a thick layer on the bottom. A MicroAire Pulse Lavage unit (4740; MicroAire Surgical Instruments, Charlot-tesville, VA) with an output pressure of up to 0.14 MPa was used. The third group of samples was treated like the second one, but after pulse lavage it was washed again in the sieve, this time under running tap water at 55°C for 1 min (12 L).

After washing, the samples and the controls were frozen at −75 °C and stored for 4 weeks before determination of residual fat content by ultrasound-aided hexane extraction. The samples were freeze-dried before the lipids were extracted in hexane. The hexane was evaporated and the resultant residual weight was expressed as a percentage of the (extracted original) dried cancellous bone powder weight.

Statistics

The results were compared using paired t-test. A p-value of < 0.05 was considered significant. The analyses were done with SPSS version 13.

Results

In the primary study, the average efficiency of pulse lavage washing (0.8 L) alone in removing fat from morselized bone samples was 80%. The average efficiency rose to 95% when 1.6 L of saline was used. In both studies, the additional warm water wash improved the results considerably (). In the main study, the difference in efficiency between pulse lavage alone and pulse lavage with warm water wash was found to be statistically significant (p = 0.008) ().

Table 1.  Primary study. Fat percentages (F%) of unprocessed and processed condyle samples and fat removal efficiencies of the different cleansing methods

Table 2.  Main study. Fat percentages (F%) of unprocessed and processed femoral head samples and fat removal efficiencies of the different cleansing methods. The difference in fat removal efficiency between samples washed with saline pulse lavage (1.6 L) and samples washed with saline pulse lavage and additional warm water was statistically significant (p = 0.008)

Discussion

In many countries most allograft bone is used as unprocessed fresh-frozen bone (Hirn Citation2001, Yates et al. Citation2005). The most usual form of allograft bone is morselized femoral head, which appears safe to use—both virologically and bacteriologically (Aspenberg Citation1998, Hirn Citation2001). Femoral heads have many advantages over allograft bone from cadavers (Aspenberg Citation1998). Living donors can be double-tested for viruses, their medical history is more reliable, and generally speaking they represent an age group with low-risk activity (regarding lifestyle).

Pulse-lavage washing lowers the bacterial bio-burden considerably (Hirn et al. Citation2001). At the same time, it also removes lipids and other loose material from the bone. Experimental studies have shown that incorporation of lipid-extracted bone is better than using a graft that has not been defatted (Thoren et al. Citation1995, van der Donk et al. Citation2003). Defatting does not appear to alter the mechanical properties of the graft (Thoren et al. Citation1995). On the contrary, washing of the graft has been shown to increase cup stability in impaction grafting (Ull-mark 2000, Arts et al. Citation2006). According to these reports, the size of the morselized graft also matters. Larger bone graft size enhances cup stability. Different washing systems were used in the two studies, but the lipid extraction capabilities of these systems were not evaluated (Ullmark Citation2000, Arts et al. Citation2006). In our study, the efficacy of washing to remove lipids was comparable to that of some other more complex methods (Lomas et al. Citation2000). The effect of pulse-lavage washing was considerably improved by using more saline. Also, washing with warm water (55°C) improved the result, but it complicates the procedure somewhat and can be omitted. Also, high temperatures may have a negative effect on bone incorporation. Pulse-lavage washing alone seems to be adequate for removal of fat from morselized bone.

Many bone banks use quite costly and time-consuming chemical and physical cleansing procedures. These methods are meant for whole femoral heads or big bone blocks, and not for morselized bone (Lomas et al. Citation2000, DePaula et al. Citation2005, Yates et al. Citation2005). For example, Lomas et al. (Citation2000) reported that the average efficiency of fat removal from whole femoral heads was 75% with the processing method they used. In our study, the average fat removal efficiency from morselized bone was 95% when 1.6 L of pulse saline was used. Thus, our cheaper and time-saving method can be recommended for cases where morselized bone is used. There was no visible difference in the color of the graft after washing with 0.8 L or 1.6 L saline. It seems that pulse-lavage washing with the standard 1-L saline bag allows adequate fat removal from an average morselized femoral head. The effect can be improved to some degree by washing the graft slightly longer after the point at which the color of the morselized material has turned white. Nevertheless, pulse-lavage washing cannot be considered to be an effective method for larger bone blocks and whole femoral heads. Its effect in removing fat and lowering bacterial bioburden is mostly limited to the surface of the bone (Hirn et al. Citation2004).

We did not measure the cleansing efficacy for blood products, but washing changed the color of the morselized bone material from reddish to white, as previously reported (Hirn Citation2001). Thus, it appears to remove most of the blood cells from the ground bone and must therefore also improve the safety from a virological standpoint. However, irradiation and heavy chemical processing methods are needed for reliable virological and bacteriological safety. Unfortunately, these methods have a negative effect on the biological and mechanical properties of allograft bone (Currey et al. Citation1997, Boyce et al. Citation1999). Pulse-lavage washing does not have such an effect, yet its efficacy in removing fat and other remnants unnecessary or even harmful for bone incorporation is certainly significant. The method we used is cheap, quick, and available in every hospital. Still, it must be emphasized that neither pulse lavage nor any other washing method can obviate the need for rigorous donor selection and laboratory screening for viruses and bacteria.

Special thanks to Heini Huhtala for statistical advice and to Miia Juntunen for valuable laboratory assistance. This research was supported by the competitive research funding of the Pirkanmaa Hospital District and the City of Tampere.

No competing interests declared.

Contributions of authors

SH and MH planned the study, carried out the experimental work, and wrote the manuscript. MH also supervised the study. MW participated in the experimental work. VV and MM analyzed the results on residual fat content.

  • Arts J J C, Verdonschot N, Buma P, Schreurs W. Larger bone graft size an washing of bone grafts prior to impaction enhances the initial stability of cemented cups. Experiments using a synthetic acetabular model. Acta Orthop 2006; 77: 227–33
  • Aspenberg P. Bank bone, infections and HIV. Acta Orthop Scand 1998; 69: 557–8
  • Boyce T, Edwards J, Scarborough N. Allograft bone. The influence of processing on safety and performance. Orthop Clin North Am 1999; 30: 571–81
  • Currey J D, Foreman J, Laketic I, Mitchell J, Pegg D E, Reilly G C. Effects of ionizing radiation on the mechanical properties of human bone. J Orthop Res 1997; 15: 111–7
  • DePaula C A, Truncale K G, Gertzman A A, Sunwoo M H, Dunn M G. Effects of hydrogen peroxide cleaning procedures on bone graft osteoinductivity and mechanical properties. Cell Tissue Bank 2005; 6: 287–98/
  • EATB (European Association of Tissue Banks) and EAMST (European Association of Musculo Skeletal Transplantation) Common Standards for Musculo Skeletal Tissue Banking. Vienna 1997
  • Grieb T A, Forng R Y, Stafford R E, Lin J, Almeida J, Bog-dansky S. Effective use of optimized, high-dose (50 kGy) gamma irradiation for pathogen inactivation of human bone allografts. Biomaterials 2005; 26: 2033–42
  • Hirn M Y. Processing of morsellised femoral heads with high-pressure saline. Acta Orthop Scand 2001; 72: 411–2
  • Hirn M, Salmela M, Vuento R. High-pressure saline washing of allografts reduces bacterial contamination. Acta Ortop Scand 2001; 72: 83–5
  • Hirn M, Laitinen M, Pirkkalainen S, Vuento R. Cefurox-ime, rifampicin and pulse lavage in decontamination of allograft bone. J Hosp Infect 2004; 56: 198–201
  • Lomas R, Drummond O, Kearney J N. Processing of whole femoral head allografts: a method for improving clinical efficacy and safety. Cell Tissue Bank 2000; 1: 193–200
  • Thoren K, Aspenberg P, Thorngren K-G. Lipid extracted bank bone. Bone conductive and mechanical properties. Clin Orthop 1995, 311: 232–46
  • Tomford W W. Transmission of disease through transplantation of musculoskeletal allografts. J Bone Joint Surg (Am) 1995; 77: 1742–54
  • Ullmark G. Bigger size and defatting of bone chips will increase cup stability. Arch Orthop Trauma Surg 2000; 120: 445–7
  • van der Donk S, Weernink T, Buma P, Aspenberg P, Slooff T J J H, Schreurs B W. Rinsing morselized allografts improves bone and tissue ingrowth. Clin Orthop 2003, 408: 302–10
  • Yates P, Thomson J, Galea G. Processing of whole femoral head allografts: validation methodology for the reliable removal of nucleated cells, lipid and soluble proteins using a multi-step washing procedure. Cell Tissue Bank 2005; 6: 277–85

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.