Inhaler technique and training in people with chronic obstructive pulmonary disease and asthma

&
Pages 91-103 | Published online: 09 Jan 2014

Abstract

Asthma and chronic obstructive pulmonary disease are both common conditions with an increasing prevalence worldwide. Inhaled therapy for these conditions has a number of advantages over systemic therapy, including reduced side effects and quicker onset of action. The effective use of inhaled therapy is critically dependent upon the nature of the drug-delivery system and the ability of the patient to use the system correctly. There are a wide number of inhaler devices on the market, each with positive and negative aspects. A crucial part of patient care is to ensure that the choice of inhaler device for the individual is an effective therapy. There are a number of interventions that can help with the choice of inhaler device and also improve the ability of the patient to use inhaled therapy. Inhaler technique training needs to be a cornerstone of the care of patients with asthma or chronic obstructive pulmonary disease to ensure optimal therapy.

Medscape: Continuing Medical Education Online

This activity has been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education through the joint sponsorship of Medscape, LLC and Expert Reviews Ltd. Medscape, LLC is accredited by the ACCME to provide continuing medical education for physicians.

Medscape, LLC designates this Journal-based CME activity for a maximum of 1 AMA PRA Category 1 Credit(s)™. Physicians should claim only the credit commensurate with the extent of their participation in the activity.

All other clinicians completing this activity will be issued a certificate of participation. To participate in this journal CME activity: (1) review the learning objectives and author disclosures; (2) study the education content; (3) take the post-test with a 70% minimum passing score and complete the evaluation at www.medscape.org/journals/expertrespiratory; (4) view/print certificate.

Release date: January 27, 2012; Expiration date: January 27, 2013

Learning objectives

Upon completion of this activity, participants will be able to:

  • • Assess properties of different types of inhalers

  • • Distinguish the ideal particle size for different inhaled medications

  • • Analyze the best practice in the use of different inhalers

  • • Perform an appropriate assessment of patients with uncontrolled symptoms despite inhaled therapy

Financial & competing interests disclosure

EDITOR

Elisa Manzotti,Editorial Director, Future Science Group, London, UK

Disclosure:Elisa Manzotti has disclosed no relevant financial relationships.

CME AUTHOR

Charles P Vega, MD,Health Sciences Clinical Professor; Residency Director, Department of Family Medicine, University of California, Irvine, CA, USA

Disclosure:Charles P Vega, MD, has disclosed no relevant financial relationships.

AUTHORS

Toby GD Capstick,Department of Respiratory Medicine, St James’s University Hospital, Beckett Street, Leeds, UK

Disclosure:Toby Capstick has received honorarium from AstraZeneca, Boeringher-Ingelheim, GlaxoSmithKline and Pfizer. He has has disclosed no other relevant financial relationships.

Ian J Clifton,Department of Respiratory Medicine, St James’s University Hospital, Beckett Street, Leeds, UK

Disclosure:Ian Clifton has received honorarium from AstraZeneca, Boeringher-Ingelheim, GlaxoSmithKline and Novartis, and an unrestricted educational grant from Pfizer. He has has disclosed no other relevant financial relationships.

Figure 1. Particle deposition in the respiratory tract.

Adapted with permission from Citation[48].

Figure 1. Particle deposition in the respiratory tract.Adapted with permission from Citation[48].
Figure 2. Asthma therapy adjustment flow chart.

Adapted with permission from Citation[3].

Figure 2. Asthma therapy adjustment flow chart.Adapted with permission from Citation[3].

Asthma and chronic obstructive pulmonary disease (COPD) are both common respiratory disorders. Worldwide approximately 300 million have asthma and 10% of the adult population over the age of 40 years may have COPD Citation[101,102]. The mainstay of treatment is with inhaled therapy for both conditions.

The NICE Citation[103] and the Global Initiative for Chronic Obstructive Lung Disease Citation[102] both recommend that prior to prescription of a new inhaler for a patient with COPD the patient should receive training and education in the use of the device. Both of these guidelines also advise that inhaler technique should be regularly assessed at each clinic visit. Likewise, the British Thoracic Society Citation[1] and the Global Initiative for Asthma Citation[101] advise that patients with asthma should have similar education prior to prescription of inhaled therapy and regular checks of inhaler technique. A recent systematic review suggested that up to 25% of patients have not received any verbal instruction for the use of their prescribed inhaler Citation[2]. The Aerosol Drug Management Improvement Team report found a clear need for specific training of patients in correct inhalation technique for the various devices currently available, and this should be repeated frequently to maintain correct inhalation technique Citation[3]. This group have also now published guidance on the importance of inhaler choice and technique in the management of patients with COPD Citation[4].

Intentional nonadherence to treatment in asthma is particularly common and has been shown to be closely related to patient’s beliefs, particularly owing to doubts about the necessity for medication, concerns about the potential for adverse drug reactions and perceived consequences and perceptions of their illnesss Citation[5–7]. Another important consideration is unintentional nonadherence. This may occur when the patient forgets to take their medication or is unable to use their prescribed inhaler devices Citation[8,9].

The use of inhaled therapy has a number of advantages over systemic (oral or intravenous) administration. It allows a smaller dose to be administered, there is a faster onset of action and fewer systemic side effects Citation[10,11]. The deposition of the inhaled drug in the lung is dependent on particle size, inhalation technique and the type of inhaler device. An integral part of the deposition of the drug within the lung is the inhaler technique of the patient using the device. Correct inhaler technique is essential for the most effective delivery of inhaled drugs; however, a number of studies have identified that errors in inhaler technique are common Citation[2,12–15]. Errors in inhaler technique are associated with suboptimal delivery of the drug into the lungs and may also potentially increase the risk of adverse effects, particularly with inhaled corticosteroids, but despite this, one study demonstrated that approximately a fifth of older patients receiving inhaled therapy could not recall receiving inhaler technique training Citation[16].

Inhaler types

There is a wide variety of different inhalers currently on the market, they can be broadly classified into pressurized metered dose (pMDI), dry powder (DPI), breath-actuated metered-dose (BA-MDI) and soft mist inhalers.

Pressurized metered-dose inhalers

pMDIs are widely prescribed as they are cheap and can deliver a wide variety of asthma or COPD medications Citation[17]. In a UK based study of people over the age of 70 years living at home, 15.8% of subjects were using an inhaler, of whom 42.8% were using a metered-dose inhaler (MDI) Citation[16]. Despite their wide prescription many patients cannot use pMDIs correctly, even with education and training Citation[13,18,19]. Lenney et al. demonstrated that only 79% of patients could use a pMDI correctly after expert training Citation[15]. Many of the difficulties with pMDIs are related to the need to coordinate activation of the device while inhaling slowly and deeply. Al-Showair et al. demonstrated that approximately 60 and 92% of patients with COPD and asthma, respectively, were inhaling too fast from a pMDI Citation[20,21].

A spacer is a device that can be attached to a pMDI and produces a reservoir into which the drug aerosol can be generated. This allows the patient to actuate the inhaler without having to coordinate inhalation. There is evidence that the addition of a spacer can increase deposition within the lung of the patient Citation[22]. Spacers achieve this by reducing aerosol particle velocity due to the spray encountering air resistance, and a reduction in aerosol particle diameter due to evaporation. The use of a spacer device has long been recognized to improve the inhalation of drugs from pMDIs, particularly for patients with difficulty using a pMDI alone Citation[16,23]. The use of a spacer in combination with a pMDI may reduce the risk of adverse side effects, particularly in relation to the use of high-dose inhaled corticosteroids Citation[24].

New developments in drug formulation have allowed for the development of new pMDIs that produce aerosols containing extra-fine particles. The use of extra-fine particle pMDIs has been shown to demonstrate equivalent efficacy to other preparations but with a reduced equivalent dose of corticosteroid Citation[25–28]. These newer formulations have been reported to be less dependent upon inhaler technique than other MDIs due to longer duration of aerosol emission Citation[29] and lung deposition being affected less by inspiratory flow Citation[30] and coordination Citation[31].

One concern about pMDIs is the ‘cold-Freon’ effect that can result from the impact of the aerosol plume on the back of the throat. Some of the newer hydrofluoralkane (HFA)-containing MDIs produced much softer and warmer plumes, when compared with the chlorofluorocarbon (CFC)-containing MDIs, which may improve patient tolerability, and therefore compliance Citation[32].

CFC-containing MDIs have gradually been phased out across Europe in recent years and many are now formulated to contain HFA propellants. This has had a significant effect on the characteristics of the spray from MDIs, in particular producing softer, warmer sprays. In one study, the HFA-beclometasone MDI was found to produce a plume with a spray duration of 510.8 ms from a Beclazone™ (IVAX, UK) 50 CFC-free MDI, 278.5 ms from a Qvar™ (TEVA, UK) 50-µg MDI, compared with 185.2 ms from a Becotide™ (GlaxoSmithKline, UK) 100-µg MDI. This was associated with a reduction in the maximum plume impact force on the throat (45.6, 34.3 and 106.1 mN, respectively. Additionally the minimum plume temperature was higher for the HFA-containing MDIs (-1.9, 3.7 and -32.2°C). The authors’ report concludes that MDIs with warm and softer plumes should minimize throat deposition and reduce the likelihood of the cold-Freon effect Citation[32].

Breath-actuated metered-dose inhalers

BA-MDIs are a development from the original pMDIs. They contain a flow trigger that ensures that inhalation and actuation of the inhaler are coordinated appropriately, as the drug is released only when the patient inhales through the inhaler device. BA-MDIs have been demonstrated to improve the deposition of aerosol within the lungs for patients who have difficulty coordinating inhalation and actuation of pMDIs Citation[31,33]. Chapman et al. found that for elderly patients, BA-MDIs were preferred when compared with standard MDIs Citation[19]. Lenney et al. found that 91% of patients had good inhaler technique with the Easi-Breathe® (IVAX, UK) inhaler device after expert training and was by far the most popular inhaler device of seven devices tested, including the pMDI, pMDI plus Volumatic® spacer (GlaxoSmithKline, UK), Accuhaler® (GlaxoSmithKline, UK) and Turbohaler® (Astrazeneca, Sweden) Citation[15]. In a later study by Ho et al. BA-MDIs were only found to be used correctly by 72% of individuals Citation[16]. An important consideration for the use of BA-MDIs is the need for the patient to be able to generate sufficient inspiratory flow to trigger the delivery of the aerosol.

Dry powder inhalers

There are a number of DPIs currently available on the market. Some of these devices are single dose, such as the HandiHaler® (Boehringer Ingelheim, Germany) or Aerolizer® (Novartis, Switzerland), that require loading of a capsule containing the drug in powder form. Others are multiple dose, such as Turbohaler (also known as the Turbuhaler) or Accuhaler (also known as the Diskus® [GlaxoSmithKline, UK]).

The main advantages DPIs have over pMDIs are that the generation of the drug aerosol is driven by the patient’s inhalation. As a consequence there is no need for an aerosol propellant or coordination between actuation of the device and inhalation. If the patient cannot generate an appropriate inspiratory flow then the drug may not be delivered optimally. A recent systematic review of studies examining inhaler technique using DPIs found that between 4 and 94% of patients did not use their inhaler correctly. The most frequently reported errors included failure to exhale prior to inhaling through the device, failure to breath-hold after inhalation, incorrect positioning of the device and failure to inhale through the device with a sufficiently high inspiratory flow Citation[2]. However, the studies included in the systematic review are subjective by nature and no consistent pattern is discernible to determine the easiest DPI to use as different studies favored different DPI devices.

Soft mist inhalers

Soft mist inhalers are a recent innovation and the only current device on the European market is the Respimat® (Boehringer Ingelheim, Germany). The Respimat does not require a propellant or the patient’s inspiratory flow to generate an aerosol. The aerosol is generated by a spring that forces the liquid drug formulation through an extremely fine nozzle system, resulting in an aerosol containing a high fine particle fraction Citation[34]. The Respimat has a long aerosol generation time and a low aerosol velocity. These features reduce problems with coordination of actuation and inhalation, and result in a higher lung and lower oropharyngeal deposition Citation[34]. However, recent data have implicated tiotropium when delivered via the Respimat device with a nonsignificant increase in cardiovascular mortality compared with placebo Citation[35]. This effect has not been observed when tiotropium is delivered via the HandiHaler DPI device Citation[36]. Although this increase in mortality may just be a chance finding, postulated reasons include the fact that the Respimat device achieves greater systemic absorption of tiotropium compared with the HandiHaler device. As a consequence, the Medicines and Healthcare products Regulatory Agency have advised that Spiriva Respimat should be used with caution in patients with known cardiac rhythm disorders Citation[104].

Aerosol science & inhaled medication

The deposition of the inhaled drug in the lung is dependent on particle size, inhalation technique and the type of inhaler device. There is a complex interaction between these three factors that results in the need for different techniques for different inhalers Citation[37,38]. Patients using a pMDI should use a slower inhalation Citation[37,39], compared with a DPI, which requires a faster inhalation rate Citation[37,40].

Effects of particle size on lung deposition

Depending on their particle size, inhaled drug particles will deposit in different regions of the lung. Particles <1 µm are likely to reach the peripheral airways and alveoli or be exhaled, particles 1–5 µm will deposit in the large and conducting airways, while particles >5 µm will predominately deposit in the oropharynx Citation[10,11].

Historical data of examining lung deposition of terbutaline demonstrated 10.7% of the metered dose was deposited in the whole lung when administered via pMDI at an inhalation flow of 30 l/min and 31.6% when administered via pMDI plus Nebuhaler at an inhalation flow of 15 l/min Citation[41]. Deposition of inhaled corticosteroids administered via pMDIs with extra-fine particle formulations have demonstrated improved lung deposition compared with conventional pMDIs Citation[42–44]. However, randomized controlled studies have, as yet, failed to demonstrate any significant differences in clinical effects compared with equivalent doses of conventional inhaled corticosteroid pMDIs Citation[25–28].

This knowledge is useful since it is known that β2 receptors predominate in the small conducting airways and alveoli; however, airway smooth muscle is present in the trachea and small conducting airways Citation[30,38]. Consequently the ideal particle size for inhaled β2-agonists will be in the top end of the range of 1–5 µm, as this would allow deposition of drug particles in the region of airway where both airway smooth muscle and β2 receptors exist. Larger particles of β2-agonists in the range of 3–6µm have been demonstrated to achieve greater lung deposition in the central and intermediate airways than small particles (1.5 µm), and consequently produce greater bronchodilation Citation[30]. By contrast, airway inflammation is present throughout the respiratory tract, although there is a similar, but more severe, inflammatory process in the peripheral airways compared with the central airways Citation[45].Consequently, a particle size distribution from <1 µm up to 5 µm may be desirable for inhaled anti-inflammatory drugs, such as corticosteroids Citation[38,46].

Usmani et al. described the lung deposition and clinical effects of three sizes (1.5, 3 and 6 µm) of monodisperse salbutamol in 12 asthmatic patients Citation[30]. Although lung deposition was greatest for the 1.5 µm particles, the 6 µm particles produced the greatest clinical response in terms of lung function. The smaller particles were less likely to be deposited in the oropharynx, which may explain the reduction in local side effects with extra-fine particle inhaled corticosteroids perpetrations Citation[47].

There are three different mechanisms of deposition of aerosols: inertial impaction, sedimentation and diffusion . However, for the particle size used in aerosol therapies of approximately 1–10 µm, only two of these mechanisms predominate – inertial impaction and gravitational sedimentation. The third mechanism, Brownian motion/diffusion, is only relevant in aerosols of less than 1 µm in diameter Citation[10], and therefore is unlikely to be of consequence for inhaled drugs.

Inertial impaction occurs in either the oropharynx or at bifurcations of main branches of the bronchial tree, particularly in the large central airways. It occurs mainly with large particles or high velocity particles (i.e., those with high inertia), where they are unable to follow the airstream when it changes direction, thus impacting on the airway wall Citation[10,48].

Gravitational sedimentation occurs for smaller particles that are able to follow the airstream and penetrate the more peripheral bronchioles and alveoli. Here the airstream flows slower, allowing the particles to settle on to the airway surfaces either during the course of slow steady breathing or during breath-holding Citation[10,48]. Breath-holding is important for smaller particle sizes owing to the increased chance of exhalation of the drug, because they can remain airborne for a considerable time Citation[30]. The mechanism of the deposition of inhaled aerosols and the size of aerosol particles has a number of implications for practice (Box 1).

Effects of inspiratory flow on lung deposition

The total lung deposition of an inhaled drug is strongly affected by the speed of inhalation. DPIs require a fast and deep inhalation to ‘suck up’ the drug in the inhaler device. A fast inhalation rate generates a large internal turbulent force in the inhaler device, which is required to break up the formulation of the metered dose to produce particles of a size distribution that will penetrate the peripheral airways Citation[38,48,49]. Failure to achieve this high internal force increases the likelihood of the dose impacting in the mouth and throat. By contrast, aerosol inhalers, such as the MDI, require a slow and deep inhalation, with an inspiratory flow rate of less than 60 l/min. This is owing to the device generating its own aerosol, and so a slower inhalation rate is required to ensure that the drug deposits in the peripheral airways, since a fast inhalation will increase the velocity of the drug particles, thus increasing inertial impaction in the oropharynx as described above Citation[21,38]. Some of the effect of excessive inspiratory flow with a pMDI can be mitigated by the particle size used in the aerosol. Usmani et al. demonstrated that increasing the inspiratory flow from 30.8 to 67.1 l/min increased the deposition of 1.5-µm particles, but reduced the deposition of 6-µm particles. However, a greater clinical effect was observed with 6-µm particles of salbutamol administered via a pMDI with good inhaler technique than with 1.5-µm particles administered via a pMDI with either good or bad inhaler technique Citation[30].

Faster inspiratory flow rates increase inertial impaction of aerosols in the oropharynx and at bifurcations in the large central airways, thus reducing lung deposition in the peripheral airways. In one study determining whole lung deposition using the charcoal block method, deposition of radiolabeled terbutaline was reduced by a third by increasing the airflow through the MDI device from 30 to 180 l/min (mean ± standard deviation: 11.2 ± 4.0 vs 7.2 ± 2.2; p < 0.05) Citation[50]. A significant proportion of patients with asthma and COPD have been shown to have an inspiratory flow too high for an MDI, which could potentially reduce the clinical effectiveness of inhaled drugs Citation[20,21].

Other studies have demonstrated that lung deposition from dry powder devices increases as inspiratory flow increases. Borgstrom et al. demonstrated that the percentage of the metered dose from a budesonide Turbohaler deposited in the lung as measured by gamma scintigraphy increased from a mean ± standard deviation 14.8 ± 3.3% at an inspiratory flow rate of 36 l/min to 27.7 ± 9.5% at 58 l/min Citation[50]. A further study highlighted the variability in dose delivered by the Turbohaler device, by demonstrating that the fine particle fraction was more strongly influenced by inspiratory flow rate through a Turbohaler compared with an Accuhaler (12–24% at 30–60 l/min vs 15–21% at 30–90 l/min, respectively) Citation[51].

As a consequence, when a patient uses an aerosol inhaler, such as the MDI, a slow inspiratory flow rate will produce significantly greater lung deposition than when used at a faster inspiratory flow rate. By contrast, when dry powder inhalers, such as a Turbohaler or Accuhaler are used, a faster inspiratory flow rate will produce significantly greater lung deposition than a slower inspiratory flow rate.

The ability of patients to use specific inhalers can vary with time. During times of increased hyperinflation, such as acute exacerbations of asthma of progression to severe emphysema, patients may not be able to generate sufficient inspiratory flow through high-resistance devices. In this situation, a low-resistance device, such as a pMDI or pMDI plus spacer, may be more appropriate.

Effect of resistance of inhaler device on lung deposition

Another important determinant of the inspiratory flow through an inhaler is the resistance to airflow through the device. The MDI is a low-resistance device and is easy to inhale through since there is little resistance to airflow. This means that the patient needs to apply less effort to inhalation to generate the appropriate inspiratory flow and optimum drug deposition. A low-resistance device, such as an MDI, means that it is relatively easy to generate too great an inspiratory flow, essentially inhaling too fast, which is a common error in the use of MDIs Citation[37,38,52].

DPI devices have a high resistance to airflow, which limits the inhalation flow rate through the device, and consequently patients using a DPI need to apply greater effort to generate the necessary inspiratory flow to allow for optimum drug delivery. The ability to generate appropriate inspiratory flow is particularly important for patients with severe airflow obstruction, young children and the elderly Citation[40]. Peak inspiratory flow through a Accuhaler, Turbohaler and HandiHaler device have been shown to be too slow among 4.9, 14.2 and 57.0% of patients with COPD, respectively Citation[20].

The effect of increased airflow resistance on inhalation flow has been demonstrated Citation[20], and it can be seen that lower inhalation flows can be achieved through the devices with the highest airflow resistance (the Easyhaler® [Orion Pharma, UK]and HandiHaler) than through devices with lower resistance, such as the Accuhaler . Consequently, using the same amount of effort of inhalation, patients can achieve faster inspiratory flows through the Accuhaler, than through a Turbohaler, HandiHaler or Easyhaler device.

Choosing the correct inhaler

One of the crucial factors in determining whether the patient has an appropriate inhaler technique is the inspiratory flow through the particular device and the ability to coordinate actuation and inhalation of the inhaler. Voshaar et al. have proposed that the use of inspiratory flow measurements and the ability to coordinate actuation and inhalation of inhalers may provide guidance to the most appropriate inhaler for individual patients Citation[53]. This guide suggests that patients who naturally have a tendency to have a fast inhalation would be better suited to DPIs, whereas those with a slower inhalation speed would be best suited to a pMDI.

Devices such as the In-Check DIAL® inspiratory flow meter (Clement Clarke Ltd, UK) can be used to ensure that patients can inhale through their inhaler device at the clinically effective inspiratory flow rate. The device mimics the internal resistance of a range of inhaler devices , allowing the measurement of inspiratory flow rate through different devices Citation[49,54]. The In-Check DIAL inspiratory flow meter can be used as part of the inhaler technique assessment to guide inhaler device selection and conserve placebo inhalers, which should be single-patient use only. If a patient is physically unable to achieve the required optimum inspiratory flow rate, there is no point checking their technique with that device. If their inspiratory flow is too great for the device then they may benefit from training and education or alternatively trying a different device.

It should be noted, however, that the inspiratory flow rates described in are the optimum inspiratory flow rates for each device listed. Patients who use any particular inhaler device, but cannot achieve the optimum inspiratory flow rate, will often gain clinical benefit from that device (assuming that their overall technique is satisfactory), but potentially not the maximum benefit. For example, if a patient can only inhale through a Turbohaler device at an inspiratory flow rate of 36 l/min, approximately 15% of the metered dose will reach the lungs, but if the inspiratory flow rate can be increased to 56 l/min then lung deposition will almost double to approximately 28% Citation[50]. It is likely that patients will achieve a clinical benefit at both inspiratory flow rates, but would seem inherently obvious that they could potentially gain greater benefit at the higher flow rate owing to greater lung deposition.

Additionally, for optimal drug delivery it is important that the inspiratory flow at the start of inhalation is fast enough to break up the weak bonds between the drug and carrier particles to ensure that the optimal particle size is achieved to allow deposition of the drug in the appropriate region of the lungs Citation[49]. If the peak inspiratory flow is only achieved gradually (i.e., an inhalation commencing with a slow inspiratory flow, which gradually increases), the initial force required to generate an appropriate drug particle size will not be achieved and the delivered dose will be reduced. A final note of caution with training aids, such as the In-Check DIAL inspiratory flow meter, is that it assesses just one component of inhaler technique and does not teach the patient how to hold, prime and position their inhaler device Citation[38].

Alternative training aids are available to assist inhaler technique training. The Turbohaler Trainer (AstraZeneca, Sweden) produces an audible whistle if the patient inhales at an inspiratory flow rate above 35 l/min. This ensures the patient is inhaling to achieve clinically significant lung deposition rather than achieving the optimal inspiratory flow rate. It is useful for patients who do not like using the Turbohaler device because they cannot taste the drug, like they can with more ‘familiar’ devices, such as the MDI. Similarly, the Accuhaler training Device (Vitalograph, Ennis, Ireland) can be used to ensure patients can achieve the optimum inspiratory flow rate above 30 l/min. The 2-Tone Trainer® (Canday Medical Ltd, UK) can be used to help patients learn the correct inspiratory flow rate through an MDI device. It mimics the airflow resistance through an MDI, such that if a patient inhales too slowly, no sound is heard, while if they inhale correctly, one tone is heard. If the patient inhales at the correct flow rate then two tones are heard. The 2-Tone Trainer has been demonstrated to maintain the recommended MDI technique post-training with improvements in Asthma Quality of Life Questionnaire score Citation[21].

Training aids, such as the In-Check DIAL inspiratory flow meter, Turbohaler Trainer, Accuhaler Training Device and 2-Tone Trainer, are tools for determining whether a patient has the physical capacity to use a particular inhaler device. These devices are just one aspect of inhaler use, therefore, it is essential that healthcare professionals have access to placebo inhaler devices to assess a patient’s overall inhaler technique, since these will allow the patient to be assessed on the priming, positioning and coordination of the device. Most UK hospitals and general practitioners have access to placebo inhalers, but many centers advise that placebo inhalers should be ‘single-patient use’ only, since there is a theoretical risk of infection when using placebo inhalers among patients Citation[105]. However, if placebo inhalers are used for more than one patient, the British Thoracic Society advise that they should be decontaminated after each time they are used (Box 2).

Since many UK centers can only obtain a limited supply of placebo inhalers, it is impossible for all patients with asthma or COPD to have their inhaler technique assessed during hospital admission or at clinic reviews. If a patient has their own inhalers, then an extra dose of these could be given if it is thought unlikely to cause undue harm. If a patient is to be newly prescribed an inhaler, a judgement must be made to decide which patients should receive education, training and assessment on correct inhaler technique using placebo inhalers prior to being given a prescription, and which patients can receive training and assessment using their new inhaler devices after receiving their dispensed prescription. In these situations, the use of the In-Check DIAL inspiratory flow meter may aid this decision as patients who inhale fast are more likely to be suitable for a DPI device, and slow inhalers are more likely to be suitable for a pMDI device.

Choice of inhaler to prescribe

While no guideline gives specific recommendations on which inhaler device should be used, they do advise that patients newly started on an inhaler should receive education and training on that device, but do not go into further details Citation[1,101–103]. The American College of Chest Physicians and American College of Asthma, Allergy and Immunology have provided more useful advice on prescribing inhalers, recommending that a number of factors are considered when prescribing inhaler devices Citation[55]. These factors included drug availability, patient ability to use, cost, convenience of device, device durability and patient or prescriber device preference Citation[55]. While these factors are perfectly reasonable issues to consider when prescribing a new inhaler device, it is strange that patient preference for the inhaler device is the last consideration, as this may affect adherence to the prescribed treatment, therefore we would suggest that a pragmatic approach for inhaler choice could be used (Box 3).

There are a number of studies assessing the preference of different inhaler devices in patients with asthma and COPD, but most are industry-sponsored studies. In fact, one review reported that "of the 29 studies, 23 were sponsored by the pharmaceutical industry, and 83% of the sponsored trials favored the device manufactured by the sponsoring company" Citation[56]. One independent study comparing multiple inhaler devices found that the most popular device was the Easi-Breathe inhaler, followed by the Autohaler® (3M, USA), Clickhaler® (Generics UK Ltd, UK) and Accuhaler. The pMDI and Turbohaler devices were ranked fifth and sixth preferred device, respectively, with pMDI via Volumatic the least preferred device Citation[15]. However, despite the fact that the Easi-Breathe inhaler was the most preferred inhaler in this study, prescribing is restricted by the limited number of drugs available in this device, with only Qvar® (Beclometasone, Teva UK) and Salamol™ (salbutamol, IVAX) being available in the Easi-Breathe in the UK.

Inhaler technique training

Inhaler technique checks need to be an integral part of the routine management of any patient with either asthma or COPD. The Aerosol Drug Management Improvement Team group proposed a practical algorithm in order to improve the instruction of patients regarding correct inhaler use Citation[3]. This algorithm emphasizes the need for a consistent assessment of asthma control, and to only step treatment up once appropriate assessments of aggravating factors, compliance and inhaler technique are assessed.

This algorithm was specifically designed with asthma in mind; however, it could equally apply to the care of people with COPD. Patient perception of their own inhaler technique correlates poorly with actual use of the inhaler, hence inhaler technique should be observed and checked regularly Citation[16].

Once a person has been identified to have an incorrect inhaler technique it is essential that action is undertaken to remedy the situation. Incorrect inhaler technique could have a direct effect upon the patient in terms of disease control and the consequent potential effects on morbidity, mortality and quality of life. There are also wider socioeconomic impacts in terms of the financial cost of the inhalers and the cost of treating exacerbations of either airways disease. In one study of 4078 adults with asthma treated with inhaled corticosteroids delivered by pMDI, poor technique was identified in 71% of patients. Asthma stability was found to be worse in patients with poorer inhaler technique (as determined by the number of errors made in their inhaler technique), than patients with good inhaler technique Citation[57].

Inhaler technique training needs to be undertaken by a healthcare professional proficient in providing inhaler technique training. There is evidence that the training is not always delivered by appropriately trained staff Citation[58,59]. The training could be delivered by a wide variety of healthcare professionals, including medical staff, nursing staff and pharmacists, depending upon the individual practices. It should not be simply assumed that all healthcare professionals have perfect inhaler technique. A number of studies have identified that a variety of healthcare professionals often have poor knowledge on the optimal use of different inhaler devices Citation[59,60]. Therefore, the regular ongoing education of healthcare professionals is likely to be of paramount importance to ensure that they are able to adequately teach patients inhaler technique, and thus not unwittingly contribute to patients’ poor inhaler technique.

Adequate time and resources need to be set aside for inhaler technique training; however, it does not need to be prolonged. Basheti et al. studied the effect of a monthly community pharmacist-delivered inhaler technique session Citation[61]. The training session only lasted a few minutes, but resulted in a clinical and statistically significant improvement in quality of life and asthma control. Another important finding from this study is that once the monthly inhaler training stopped there was a decline in inhaler technique with an associated decline in some asthma outcomes. This would suggest that inhaler technique training may need to be a continuous process rather than a one-off session at the initiation of therapy, and patients on long-term inhaled therapy should not be assumed to be proficient in the use of their inhaler therapies.

The components of inhaler technique training are also important. In a small study, the most effective method of delivering training for the use of a Turbohaler was a combination of verbal counseling and physical demonstration Citation[61].

Expert commentary

Asthma and COPD are both common conditions worldwide with an increasing prevalence. Both conditions are associated with a significant morbidity and mortality. Effective drug therapies are available in the form of inhaled corticosteroids and bronchodilators. These therapies can be delivered by a variety of different inhalation devices.

Correct use of the inhalation devices will maximize the beneficial effects of therapy, while minimizing potential adverse effects. Inhaler technique assessment and training needs to be delivered at the initiation of therapy with a new inhaler device, but also needs to be repeated throughout the period that the patient received inhaled drug therapy. A detailed assessment of the patient’s coordination and inspiratory flow patterns could potentially allow for a recommendation of particular inhalers that are more suitable for individual patients. This would potentially increase the chances of successful inhalation therapy with consequent positive effects on the control of the patient’s condition.

Identification of poor inhaler technique is an integral part of the management of patients with asthma or COPD. Identification of poor inhaler technique should lead to either inhaler technique training or instigate a change of device to enable the patient to use their inhaler accurately. Advances also need to be made to address the questions that surround the most efficient method of delivering inhaler technique education. These questions include the frequency of inhaler check and who should deliver the information. This may be most appropriate from healthcare professionals, but the use of expert patients could be an alternative.

Five-year view

Identification of poor inhaler technique and the provision of appropriate training are going to remain essential for the management of patients with asthma and COPD for the foreseeable future. Further research needs to address questions regarding the nature and frequency of inhaler technique training. New ways of delivering inhaler technique training should be developed, such as via video delivered to smartphones or via online asthma action plans with integrated inhaler technique video clips. Inhaler device development should focus on producing devices that are easy to use in an effort to maximize the efficacy of inhaled therapy.

Table 1. Resistance of dry powder inhaler devices.

Table 2. Suitability of inhaler devices according to the patient’s inspiratory flow and ability to coordinate inhaler actuation and inhalation.

Table 3. Inhaler devices that can be mimicked by the In-Check Device®.

Box 1. Implications for practice on the mechanism of aerosol deposition and particle size.

  • • Particle size is important: those that are too small may be exhaled; those that are too large experience inertial impaction in the oropharynx and large conducting airways.

  • • Increased aerosol particle speed increases the probability of deposition by impaction in the oropharynx and large conducting airways; slow aerosol particle speed allows more particles to penetrate the peripheral bronchial tree.

  • • Increasing the inhalation volume allows the aerosol to penetrate peripheral bronchioles.

  • • Breath-holding increases gravitational sedimentation.

Box 2. Guidance for decontamination of placebo inhalers.

Inhaler canisters and other devices that can be washed must be:

  • • Disassembled where possible

  • • Washed thoroughly, ideally in an ultrasound bath or according to guidelines

  • • Soaked for 1 h in a hypochlorite solution

    • – 10,000 parts per million if there is potential blood contamination

      – 1000 parts per million if no risk of blood contamination

  • • Dried thoroughly prior to further use.

Dry powder devices and device parts that cannot be washed:

  • • Decontaminated by thoroughly wiping with an appropriate alcohol wipe

Box 3. Suggested pragmatic approach towards inhaler choice.

  • • Confirm the diagnosis: is the diagnosis asthma or chronic obstructive pulmonary disease?

  • • Determine the severity of respiratory disease: the treatment required for asthma and chronic obstructive pulmonary disease should be sufficient to treat the severity of the condition.

  • • Objectively assess which device the patient can use: using placebo inhalers and training tools as appropriate.

  • • Is the patient happy with that device? Once the patient has been taught how to use a particular inhaler device, it is imperative that their views are sought to ensure that they would be happy to use that device.

  • • Decide on the class of drug required: with few exceptions, the choice of the actual drug to prescribe within a class is unlikely to be as important as the class of drug.

  • • Select the drug that is available in that device: once the inhaler device and class of drug is known, the drug often picks itself.

Key issues

  • • Chronic obstructive pulmonary disease and asthma are both common conditions with an increasing worldwide prevalence.

  • • Inhaled delivery of drugs is essential for the management of chronic obstructive pulmonary disease and asthma to minimize systemic side effects of the currently available therapies.

  • • A wide variety of inhalers are available on the market, all of which have relative positive and negative aspects.

  • • Inhaler technique is repeatedly recognized to be poor in a significant number of patients.

  • • Inhaler technique training and education has been demonstrated to be successful.

  • • Advances in inhaler design and improvement in education may result in more efficient delivery of inhaled drugs.

References

  • British Thoracic Society. British Guideline on the management of asthma. Thorax63(Suppl. 4), iv1–iv121 (2008).
  • Lavorini F, Magnan A, Dubus JC et al. Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD. Respir. Med.102(4), 593–604 (2008).
  • Crompton GK, Barnes PJ, Broeders M et al. The need to improve inhalation technique in Europe: a report from the Aerosol Drug Management Improvement Team. Respir. Med.100(9), 1479–1494 (2006).
  • Broeders ME, Vincken W, Corbetta L. The ADMIT series – Issues in Inhalation Therapy. 7. Ways to improve pharmacological management of COPD: the importance of inhaler choice and inhalation technique. Prim. Care Respir. J.20(3), 338–343 (2011).
  • Horne R, Weinman J. Self-regulation and self-management in asthma: exploring the role of illness perceptions and treatment beliefs in explaining non-adherence to preventer medication. Psychol. Health17, 7–32 (2002).
  • Horne R, Weinman J. Patient’s beliefs about prescribed medicines and their role in adherence to treatment in chronic physical illness. J. Psychosom. Res.47(6), 555–567 (2008).
  • Menckeberg TT, Bouvy ML, Bracke M et al. Beliefs about medicines predict refill adherence to inhaled corticosteroids. J. Psychosom. Res.64(1), 47–54 (2008).
  • Cochrane GM, Horne R, Chanez P. Compliance in asthma. Respir. Med.93(11), 763–769 (1999).
  • Horne R. Compliance, adherence, and concordance: implications for asthma treatment. Chest130(1 Suppl.), 65S–72S (2006).
  • Newman SP. Aerosol deposition considerations in inhalation therapy. Chest88(Suppl. 2), 152S–160S (1985).
  • Everard ML. Guidelines for devices and choices. J. Aerosol Med.14(Suppl. 1), S59–S64 (2001).
  • Nimmo CJ, Chen DN, Martinusen SM, Ustad TL, Ostrow DN. Assessment of patient acceptance and inhalation technique of a pressurized aerosol inhaler and two breath-actuated devices. Ann. Pharmacother.27(7–8), 922–927 (1993).
  • Crompton GK. Problems patients have using pressurized aerosol inhalers. Eur. J. Respir. Dis. Suppl.119, 101–104 (1982).
  • Hesselink AE, Penninx BW, Wijnhoven HA, Kriegsman DM, van Eijk JT. Determinants of an incorrect inhalation technique in patients with asthma or COPD. Scand. J. Prim. Health Care19(4), 255–260 (2001).
  • Lenney J, Innes JA, Crompton GK. Inappropriate inhaler use: assessment of use and patient preference of seven inhalation devices. EDICI. Respir. Med.94(5), 496–500 (2000).
  • Ho SF, OMahony MS, Steward JA, Breay P, Burr ML. Inhaler technique in older people in the community. Age Ageing33(2), 185–188 (2004).
  • Lavorini F, Corrigan CJ, Barnes PJ et al. Retail sales of inhalation devices in European countries: so much for a global policy. Respir. Med.105(7), 1099–1103 (2011).
  • Allen SC, Prior A. What determines whether an elderly patient can use a metered dose inhaler correctly? Br. J. Dis. Chest80(1), 45–49 (1986).
  • Chapman KR, Love L, Brubaker H. A comparison of breath-actuated and conventional metered-dose inhaler inhalation techniques in elderly subjects. Chest104(5), 1332–1337 (1993).
  • Al-Showair RA, Tarsin WY, Assi KH, Pearson SB, Chrystyn H. Can all patients with COPD use the correct inhalation flow with all inhalers and does training help? Respir. Med.101(11), 2395–2401 (2007).
  • Al-Showair RA, Pearson SB, Chrystyn H. The potential of a 2Tone Trainer to help patients use their metered-dose inhalers. Chest131(6), 1776–1782 (2007).
  • Newman SP. Spacer devices for metered dose inhalers. Clin. Pharmacokinet.43(6), 349–360 (2004).
  • Bloomfield P, Crompton GK, Winsey NJ. A tube spacer to improve inhalation of drugs from pressurised aerosols. Br. Med. J.2(6203), 1479 (1979).
  • Brown PH, Blundell G, Greening AP, Crompton GK. Do large volume spacer devices reduce the systemic effects of high dose inhaled corticosteroids? Thorax45(10), 736–739 (1990).
  • Fireman P, Prenner BM, Vincken W, Demedts M, Mol SJ, Cohen RM. Long-term safety and efficacy of a chlorofluorocarbon-free beclomethasone dipropionate extrafine aerosol. Ann. Allergy Asthma Immunol.86(5), 557–565 (2001).
  • Gross G, Thompson PJ, Chervinsky P, Vanden Burgt J. Hydrofluoroalkane-134a beclomethasone dipropionate, 400 microg, is as effective as chlorofluorocarbon beclomethasone dipropionate, 800 microg, for the treatment of moderate asthma. Chest115(2), 343–351 (1999).
  • Papi A, Paggiaro P, Nicolini G, Vignola AM, Fabbri LM. Beclomethasone/formoterol vs fluticasone/salmeterol inhaled combination in moderate to severe asthma. Allergy62(10), 1182–1188 (2007).
  • Papi A, Paggiaro PL, Nicolini G, Vignola AM, Fabbri LM. Beclomethasone/formoterol versus budesonide/formoterol combination therapy in asthma. Eur. Respir. J.29(4), 682–689 (2007).
  • Fabbri LM, Nicolini G, Olivieri D, Papi A. Inhaled beclometasone dipropionate/formoterol extra-fine fixed combination in the treatment of asthma: evidence and future perspectives. Expert Opin. Pharmacother.9(3), 479–490 (2008).
  • Usmani OS, Biddiscombe MF, Barnes PJ. Regional lung deposition and bronchodilator response as a function of beta2-agonist particle size. Am. J. Respir. Crit. Care Med.172(12), 1497–1504 (2005).
  • Leach CL, Davidson PJ, Hasselquist BE, Boudreau RJ. Influence of particle size and patient dosing technique on lung deposition of HFA-beclomethasone from a metered dose inhaler. J. Aerosol Med.18(4), 379–385 (2005).
  • Gabrio BJ, Stein SW, Velasquez DJ. A new method to evaluate plume characteristics of hydrofluoroalkane and chlorofluorocarbon metered dose inhalers. Int. J. Pharm.186(1), 3–12 (1999).
  • Newman SP, Weisz AW, Talaee N, Clarke SW. Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique. Thorax46(10), 712–716 (1991).
  • Dalby R, Spallek M, Voshaar T. A review of the development of Respimat Soft Mist Inhaler. Int. J. Pharm.283(1–2), 1–9 (2004).
  • Singh S, Loke YK, Enright PL, Furberg CD. Mortality associated with tiotropium mist inhaler in patients with chronic obstructive pulmonary disease: systematic review and meta-analysis of randomised controlled trials. BMJ342, d3215 (2011).
  • Tashkin DP, Celli B, Senn S et al. A 4-year trial of tiotropium in chronic obstructive pulmonary disease. N. Engl. J. Med.359(15), 1543–1554 (2008).
  • Chrystyn H, Price D. Not all asthma inhalers are the same: factors to consider when prescribing an inhaler. Prim. Care Respir. J.18(4), 243–249 (2009).
  • Haughney J, Price D, Barnes NC, Virchow JC, Roche N, Chrystyn H. Choosing inhaler devices for people with asthma: current knowledge and outstanding research needs. Respir. Med.104(9), 1237–1245 (2010).
  • Clarke SW, Pavia D, Newman SP. Influence of different inhalation modes on the efficacy of pressurized aerosol bronchodilators. Eur. J. Respir. Dis. Suppl.119, 79–88 (1982).
  • Pedersen S, Hansen OR, Fuglsang G. Influence of inspiratory flow rate upon the effect of a Turbuhaler. Arch. Dis. Child.65(3), 308–310 (1990).
  • Newman S, Steed K, Hooper G, Kallen A, Borgstrom L. Comparison of gamma scintigraphy and a pharmacokinetic technique for assessing pulmonary deposition of terbutaline sulphate delivered by pressurized metered dose inhaler. Pharm. Res.12(2), 231–236 (1995).
  • Leach CL, Davidson PJ, Boudreau RJ. Improved airway targeting with the CFC-free HFA-beclomethasone metered-dose inhaler compared with CFC-beclomethasone. Eur. Respir. J.12(6), 1346–1353 (1998).
  • Leach CL, Davidson PJ, Hasselquist BE, Boudreau RJ. Lung deposition of hydrofluoroalkane-134a beclomethasone is greater than that of chlorofluorocarbon fluticasone and chlorofluorocarbon beclomethasone : a cross-over study in healthy volunteers. Chest122(2), 510–516 (2002).
  • De Backer W, Devolder A, Poli G et al. Lung deposition of BDP/formoterol HFA pMDI in healthy volunteers, asthmatic, and COPD patients. J. Aerosol Med. Pulm. Drug Deliv.23(3), 137–148 (2010).
  • Hamid Q, Song Y, Kotsimbos TC et al. Inflammation of small airways in asthma. J. Allergy Clin. Immunol.100(1), 44–51 (1997).
  • Leach C, Colice GL, Luskin A. Particle size of inhaled corticosteroids: does it matter? J. Allergy Clin. Immunol.124(6 Suppl.), S88–S93 (2009).
  • Vanden Burgt JA, Busse WW, Martin RJ, Szefler SJ, Donnell D. Efficacy and safety overview of a new inhaled corticosteroid, QVAR (hydrofluoroalkane-beclomethasone extrafine inhalation aerosol), in asthma. J. Allergy Clin. Immunol.106(6), 1209–1226 (2000).
  • Bell J. Why optimise inhaler technique in asthma and COPD? Br. J. Prim. Care Nurs.2, 37–39 (2008).
  • Chrystyn H. Is inhalation rate important for a dry powder inhaler? Using the In-Check Dial to identify these rates. Respir. Med.97(2), 181–187 (2003).
  • Borgstrom L, Bondesson E, Moren F, Trofast E, Newman SP. Lung deposition of budesonide inhaled via Turbuhaler: a comparison with terbutaline sulphate in normal subjects. Eur. Respir. J.7(1), 69–73 (1994).
  • Palander A, Mattila T, Karhu M, Muttonen E. In vitro comparison of three salbutamol containing multidose dry powder inhalers: Buventol Easyhaler®, Inspiryl Turbuhaler® and Ventoline Diskus®. Clin. Drug Investig.20(1), 25–33 (2000).
  • Newman SP, Pavia D, Garland N, Clarke SW. Effects of various inhalation modes on the deposition of radioactive pressurized aerosols. Eur. J. Respir. Dis. Suppl.119, 57–65 (1982).
  • Voshaar T, App EM, Berdel D et al. [Recommendations for the choice of inhalatory systems for drug prescription]. Pneumologie55(12), 579–586 (2001).
  • Nsour WM, Alldred A, Corrado J, Chrystyn H. Measurement of peak inhalation rates with an in-check meter to identify an elderly patient’s ability to use a turbuhaler. Respir. Med.95(12), 965–968 (2001).
  • Dolovich MB, Ahrens RC, Hess DR et al. Device selection and outcomes of aerosol therapy: Evidence-based guidelines: American College of Chest Physicians/American College of Asthma, Allergy, and Immunology. Chest127(1), 335–371 (2005).
  • Anderson P. Patient preferences for and satisfaction with inhaler devices. Eur. Respir. Rev.14(96), 109–116 (2005).
  • Giraud V, Roche N. Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability. Eur. Respir. J.19(2), 246–251 (2002).
  • Burton AJ. Asthma inhalation devices: what do we know? Br. Med. J.288(6431), 1650–1651 (1984).
  • Interiano B, Guntupalli KK. Metered-dose inhalers. Do health care providers know what to teach? Arch. Intern. Med.153(1), 81–85 (1993).
  • Hanania NA, Wittman R, Kesten S, Chapman KR. Medical personel’s knowledge of and ability to use inhaling devices. Metered-dose inhalers, spacing chambers, and breath-actuated dry powder inhalers. Chest105(1), 111–116 (1994).
  • Basheti I, Reddel HK, Armour CL, Bosnic-Anticevich SZ. Pharmacists’ understanding of patient education on metered-dose inhaler technique. Ann. Pharmacother.34(11), 1249–1256 (2007).
  • Assi K, Chrystyn H. The different resistance of dry powder inhalers (DPIs). Am. J. Respir. Crit. Care Med.163(5), A443 (2001).
  • Chodosh S, Flanders JS, Kesten S, Serby CW, Hochrainer D, Witek TJ Jr. Effective delivery of particles with the HandiHaler dry powder inhalation system over a range of chronic obstructive pulmonary disease severity. J. Aerosol Med.14(3), 309–315 (2001).

Websites

Inhaler technique and training in people with chronic obstructive pulmonary disease and asthma

To obtain credit, you should first read the journal article. After reading the article, you should be able to answer the following, related, multiple-choice questions. To complete the questions (with a minimum 70% passing score) and earn continuing medical education (CME) credit, please go to http://www.medscape.org/journal/expertrespiratory. Credit cannot be obtained for tests completed on paper, although you may use the worksheet below to keep a record of your answers. You must be a registered user on Medscape.org. If you are not registered on Medscape.org, please click on the New Users: Free Registration link on the left hand side of the website to register. Only one answer is correct for each question. Once you successfully answer all post-test questions you will be able to view and/or print your certificate. For questions regarding the content of this activity, contact the accredited provider, [email protected]. For technical assistance, contact [email protected]. American Medical Association’s Physician’s Recognition Award (AMA PRA) credits are accepted in the US as evidence of participation in CME activities. For further information on this award, please refer to http://www.ama-assn.org/ama/pub/category/2922.html. The AMA has determined that physicians not licensed in the US who participate in this CME activity are eligible for AMA PRA Category 1 Credits™. Through agreements that the AMA has made with agencies in some countries, AMA PRA credit may be acceptable as evidence of participation in CME activities. If you are not licensed in the US, please complete the questions online, print the AMA PRA CME credit certificate and present it to your national medical association for review.

Activity Evaluation: Where 1 is strongly disagree and 5 is strongly agree

1. Your patient is a 22-year-old woman with recently diagnosed asthma. She requires treatment with an inhaled corticosteroid plus short-acting inhaled albuterol for rescue therapy. What should you consider regarding different types of inhaler before writing her a prescription?

  • A Spacers are ineffective in improving drug delivery among persons using pMDIs

  • B Extra-fine particle pMDIs require a higher dose of corticosteroid

  • C BA-MDIs require the patient to generate at least moderate inspiratory flow

  • D The Accuhaler has consistently been demonstrated to be the easiest DPI to use

2. What is the best particle size for this patient’s inhaled corticosteroid and β2-agonist to ensure the best treatment efficacy?

  • A <1 µm

  • B 4 µm

  • C 12 µm

  • D ≥15 µm

3. What can you tell this patient regarding the use of her inhalers?

  • A DPIs require a slow and steady inspiratory effort

  • B pMDIs require a fast and deep inhalation

  • C Faster inspiratory flow rates reduce the impaction of aerosols in the oropharynx

  • D Lung deposition from dry powder devices increases as inspiratory flow increases

4. The patient leaves with her prescription and returns for a follow-up visit 4 weeks later. At this time, she reports that she still has frequent symptoms of shortness of breath and poor exercise tolerance. What is the next best step in her care?

  • A Assess compliance and aggravating factors for her asthma

  • B Check her inhaler technique

  • C Consider changing her inhaler

  • D Increase the dose of her inhaled corticosteroid

Notes

Data taken from Citation[105].

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.