39
Views
3
CrossRef citations to date
0
Altmetric
Original Research

Evaluation of interface quality in organ-cultured lamellar corneal transplants

, , , , , , & show all
Pages 967-972 | Published online: 17 Jul 2012

Abstract

Background

With increasing numbers of lamellar keratoplasties, eye banks are challenged to deliver precut lamellar donor tissue. In Europe, the most common technique of corneal storage is organ culture which requires a deswelling process before surgical processing. The aim of this study was to investigate the influence of different deswelling times on the cutting plane quality after microkeratome-assisted lamellar dissection.

Methods

Eight paired donor corneas (16 specimens) not suitable for transplantation were organ cultured under standard conditions at the Eye Bank of the Ludwig-Maximilians Universität, Munich, Germany. Pairs of corneal buttons were analyzed during the deswelling process in dextrane-containing medium. While one cornea was cut at an early time point during the deswelling process and put back into deswelling medium thereafter, the partner cornea was completely deswollen and dissected after 72 hours. Specimens were then further processed for scanning electron microscopy. Surface quality was assessed both digitally using Scanning Probe Imaging Processing software, and manually by three blinded graders.

Results

The corneal buttons processed at the beginning of the deswelling process had a smoother surface when compared to the partner cornea that was cut at the end of the deswelling process. In our setting, no relevant difference was detectable between manual and automated microkeratome dissection.

Conclusion

For lamellar keratoplasty, organ-cultured corneas should be processed at an early stage during the deswelling process. We interpret the smoother dissection plane during early deswelling as a result of mechanical properties in a highly hydrated cornea.

Introduction

Lamellar keratoplasty is becoming an increasingly applied surgical procedure.Citation1Citation3 The reasons are that new concepts of posterior lamellar keratoplasty (ie, Descemet’s stripping endothelial keratoplasty or deep posterior lamellar keratoplasty) have been introduced and developed by Melles et al,Citation4,Citation5 Terry and Oustey,Citation6 and Price.Citation7 Furthermore, modern microkeratomes have been applied for anterior lamellar keratoplasty resulting in more predictable cutting depth and surface quality.Citation8Citation13 As the numbers of lamellar keratoplasty procedures are increasing, eye banks are increasingly asked to provide precut lamellar corneal tissue. With relative shortage of corneas,Citation14 precut lamellar processing allows two lamellar grafts from one cornea. Several studies have been conducted showing the advantages and disadvantages of preserving precut donor tissue in cold storage.Citation15Citation19

In Europe, the most commonly used storage method is organ culture.Citation20 This method offers distinct advantages over cold storage such as valid assessment of the number of vital endothelial cellsCitation21 and control of sterility.Citation22Citation24 Moreover, it allows long storage times of more than 30 days.Citation25 Disadvantages of organ culture are the high costs as well as the need of a deswelling process prior to corneal transplantation.Citation26,Citation27 This deswelling process is necessary given that significant corneal swelling occurs during organ culture. Deswelling is usually performed by applying a hyperosmolaric medium (ie, 5% dextran-containing medium) for an optimal time of around 32 hours.Citation28

Similar to laser-assisted in situ keratomileusis (LASIK) and other refractive techniques, the smoothness of the interface between the donor’s and the recipient's tissue is of major importance for the visual outcome of lamellar keratoplasty.Citation29 The aim of the current study is to evaluate the lamellar dissection plane quality at different stages during the deswelling process of organ cultured donor corneas.

Materials and methods

Institutional Review Board approval was obtained in January 2010.

Cornea procurement

Eight cornea pairs (16 corneas) of seropositive donors not suitable for transplantation were obtained according to the Guidelines of the European Eye Bank Association.Citation30 After slit lamp evaluation was conducted to ensure that the corneas were not scarred, whole eyes were thoroughly cleansed in 0.9% NaCl solution, immersed in 5% polyvinylpyrrolidone iodine, and rinsed again with sodium chloride solution. Corneoscleral discs were removed, fixed on a cornea disc holder, and stored in 50 mL tissue culture flasks (Primaria™ Tissue Culture Flask; Falcon-Becton Dickinson Lab ware, Franklin Lakes, NJ).

Organ culture storage

Organ culture medium consisted of Eagle’s minimum essential medium with Earle’s salts and 25 mM Hepes buffer (GIBCO, Glasgow, UK), containing 2% fetal calf serum, 2 mM glutamine, 100 U/mL penicillin, 0.1 mg/mL streptomycin, and 0.25 μg/mL amphotericin B. Corneas were cultured in a standard incubator at 37°C with the medium changed every 10 days. Deswelling was performed by placing the cornea discs in deswelling medium (Eagle’s minimum essential medium with Earle’s salts, and 25 mM Hepes buffer, which contains 2% fetal calf serum, 2 mM glutamine, 100 U/mL penicillin, 0.1 mg/ml streptomycin, 0.25 μg/mL amphotericin B, and 5% dextran 500) (distribution of mol weights: 425–575 kDA Sigma-Aldrich, Munich, Germany).

Evaluation of interface quality at different deswelling periods

After transferring the paired corneas into the deswelling medium, one was dissected after 72 hours, a duration which has been established to provide maximal deswelling.Citation28 The corresponding corneas were cut at earlier time points during the deswelling process (ie, 0 hours and 48 hours). After corneal dissection, the specimens were placed back into the deswelling medium ().

Figure 1 Flowchart of the study design.

Notes: Eight paired human corneas not suitable for transplantation were examined. While one cornea of the donor was cut after a variable deswelling time (0 hours, or 48 hours) and thereafter placed back into deswelling medium, the other cornea was processed after 72 hours of deswelling. SEM was performed after 72 hours in deswelling medium for each cornea and surface roughness of SEM images was compared thereafter by two methods.
Abbreviation: SEM, scanning electron microscopy.
Figure 1 Flowchart of the study design.

Lamellar preparation of donor corneas

In order to evaluate possible eye bank settings, two different types of microkeratomes were used.

Manual microkeratome pass

For the present study, a manual-guided microkeratome (Moria ONE, Antony, France) in combination with the artificial anterior chamber system (ALTK; Moria ONE) was used. A free cap lamellar dissection was performed by operating a precalibrated microkeratome head of 350 μm. The oscillation rate was 15000 rpm. The pressure of the anterior chamber was set at 60 mmHg and controlled by tonometry (Barraquer tonometer).

Two corneas were processed at 0 hours deswelling, three at 48 hours deswelling. Corneas were processed pairwise (ie, the corresponding five corneas were cut in the same manner at 72 hours).

Automated microkeratome pass

In a second setting, we used the AMADEUS™ 2 microkeratome in conjunction with the MOZART™ anterior chamber system (SIS Surgical Instrument Systems, Port, Switzerland). In all donor corneas, an 8.5 mm suction ring with a 350 μm cutting head was applied. The blade oscillation rate was 11000 rps and the advance rate was 1.5 mm/sec. The infusion bottle height was set at 200 cm to achieve >60 mmHg of pressure inside the artificial anterior chamber. The pressure was measured using a Barraquer tonometer. The “free cap” modus on the microkeratome control unit was activated. After corneal dissection, the specimen was placed back into deswelling medium ().

Six corneas were processed using automated pass (variable swelling times: 0 hours [one] and 48 hours [two]). The corresponding corneas were processed at 72 hours.

Electron microscopy

Corneal specimens for scanning electron microscopy (SEM) were postfixed in osmium tetroxide 2% (Dalton’s fixative), dehydrated in ethanol, dried to the critical point, sputter-coated in gold, and photographed using a ISM-35 CF electron microscope (JEOL, Tokyo, Japan).

SEM images were acquired from the central corneal bed, and additional images of the stromal bed of the cap were taken using manually guided microkeratome. Caps of mechanically cut corneas were not evaluated due to the increased likelihood of bacterial contamination in our setting.

Assessment of corneal interface quality

Roughness Average Score (RAS)

The central 100 X SEM image of the corneal interface was analyzed with the Scanning Probe Image Processor software (SPIP v.4.8.1; Image Metrology, Lyngby, Denmark) as published previously.Citation10 In brief, this software allows for an assessment of surface smoothness by calculating the height of surfaces from the fractal dimensions. For each sample, the analysis of the surface was performed by carrying out the Roughness Average Score (RAS) function of the software.

Individual surface roughness analysis (Individual scoring)

Individual Scoring (IS) was performed as published previously. Citation10 Images were graded by three masked observers who were asked to rate the overall smoothness or roughness of the images, while noting chatter lines and tissue tags of the stromal bed. The photographs were labeled 1–9 without disclosing the group assignment, and were presented in a random order to the masked observers. Each sample was graded as follows: 1 = smoothest samples among all; 2 = next smoothest; 3 = median group; 4 = rough, but not worst; 5 = roughest samples among all. Of each sample, the mean grading from all three observers was calculated.

Statistical analysis

Statistical analysis was performed using the Statistical Package for the Social Sciences version 19.0 (SPSS, Inc., Chicago, IL). For calculation of differences in IS, a series of paired samples t-tests were applied because observer grading as mentioned above was based upon normal distribution. For analysis of RAS, non-parametric tests were computed.

Results

Reproducibility of interface quality assessment

To evaluate the reproducibility of the interface assessment, both methods (RAS and IS) were compared (see ). Spearman’s rank correlation coefficient was calculated to be rs = 0.66.

Figure 2 Comparison of the two methods used to interpret surface quality (IS by blinded graders and RAS using the SPIP software [Image Metrology, Lyngby, Denmark]).

Note: There was a correlation of these two methods with Spearman’s rank correlation coefficient (r2 = 0.66).
Abbreviations: SPIP, Scanning Probe Image Processor; IS, individual score; RAS, roughness average score.
Figure 2 Comparison of the two methods used to interpret surface quality (IS by blinded graders and RAS using the SPIP software [Image Metrology, Lyngby, Denmark]).

Overall analysis

Overall 16 surfaces were analyzed: three obtained at 0 hours deswelling; five at 48 hours deswelling; and eight after 72 hours of deswelling. Surface roughness analysis showed a trend of smoother interface when cutting the cornea after the shortest deswelling time (0 hours) (IS and RAS analysis) (RAS 0 hours: 16.5 [mean], 16.1[median], standard deviation 1.1; RAS 48 hours: 17.4 [mean], 18.3 [median], ±2.9; RAS 72 hours: 21.0 [mean], 22.5 [median], ±6.0 ; IS 0 hours: 2.8 [mean], ±1.5; IS 48 hours: 2.9 [mean], ±0.7, IS 72 hours: 3.4 [mean], ±1.0) (see ). Cutting corneas after 72 hours (longest deswelling period) resulted in the roughest surface (RAS and IS analysis); however, the difference between the groups was not statistically significant. Corneas processed after 48 hours showed a rougher surface than corneas cut before the deswelling process (0 hours) both in the IS and RAS analysis. A statistically significant difference was obtained only for IS between 0 hours and 48 hours (t-test for paired samples, P = 0.001). However, the difference of surface quality between 48 and 72 hours of deswelling was only minimal (see ).

Figure 3 Analysis of surface quality of all specimens cut at 0 hours, 48 hours, and 72 hours of deswelling.

Notes: Computerized analysis (RAS): A, mean (blue), median (red) as well as the results of three blinded graders (IS): B revealed a trend of smoother dissection plane of corneas processed during early deswelling (0 hours). For difference between 0 hours and 48 hours a statistically significant P-value (P < 0.01) was calculated using paired t-tests.
Abbreviations: RAS, roughness average score; IS, individual scoring.
Figure 3 Analysis of surface quality of all specimens cut at 0 hours, 48 hours, and 72 hours of deswelling.

Comparison of mechanic versus automated microkeratome pass

All data obtained were additionally analyzed according to manual and automated dissection. There was no statistically significant difference between the two groups (Fisher’s exact test).

Discussion

The trend away from full thickness penetrating keratoplasty to lamellar keratoplasty and the relative shortage of donor tissue has raised the question of whether eye banks should provide precut lamellar donor tissue.Citation15,Citation31Citation33 If this were realized, the anterior and posterior sections of a single cornea could be used for different recipients.

While several studies are available for precut donor material in cold storage,Citation15,Citation16,Citation34,Citation35 little is known about lamellar preparation in organ culture. In Europe, organ culture is the most common storage method for corneas.Citation20 There are several advantages of organ culture including the valid assessment of cell vitality; however, a deswelling process before transplantation is needed. On the other hand, similar to LASIK, the surface quality of the transplanted corneal lamella may play an important role for the visual outcome.Citation29

We designed this study to determine what time point of microkeratome dissection during deswelling after organ culture provides the best surface quality. There was a statistically significant smoother interface upon individual scoring for corneas processed before the deswelling process as compared to corneas processed at a later time point. Although the two methods used showed good reproducibility, we failed to detect a statistically significant advantage for software processed surface analysis. This might be due to different testing of the data for statistical reasons and due to small numbers. However, both individual scoring and computerized roughness analysis methods revealed a trend of smoother interface in earlier processed corneas with no differences between manual and automated microkeratome dissection.

One possible explanation for this finding could be the anatomy of the cornea – in the anterior stroma thin collagen lamellae run obliquely to the corneal surface.Citation36,Citation37 One could speculate that these lamellae are tenser in a swollen state, thus providing a better condition for dissection. Additionally, a more edematous state of the cornea leads to a larger space between the collagen fibrils therefore minimizing the number of damaged fibrils during the microkeratome pass. We believe this should result in a smoother interface.

Another reason could be the fact that small irregularities which occur during the microkeratome pass may diminish due to the volume reduction of the corneal stroma during the deswelling process.

We are aware of the fact that the limited count of investigated corneas is a weak point in our study. Statistical analysis did not show a significant difference for all data obtained, mainly due to the small numbers of corneal pairs used in the study. However, as we investigated human corneas under realistic eye bank conditions, there are only a limited amount of human corneas available to undertake such a study.

In conclusion, our findings support the notion that lamellar dissection of edematous corneas may result in a smoother cutting plane than dissection at the end of the deswelling process in organ cultured corneas. This finding should be taken into account when implementing the supply of precut lamellar corneal tissue into an eye bank setting while working with organ culture. Further studies are needed to ensure that our findings regarding the cutting plane quality goes along with equal accuracy of donor lamellar thickness.

Disclosure

The authors report no conflicts of interest in this work.

References

  • TanDTMehtaJSFuture directions in lamellar corneal transplantationCornea2007269 Suppl 1S21S2817881911
  • TanDTParthasarathyADeep anterior lamellar keratoplasty for keratoconusCornea20072681025102617721317
  • AnshuAParthasarathyAMehtaJSHtoonHMTanDTOutcomes of therapeutic deep lamellar keratoplasty and penetrating keratoplasty for advanced infectious keratitis: a comparative studyOphthalmology2009116461562319243833
  • MellesGREgginkFALanderFA surgical technique for posterior lamellar keratoplastyCornea19981766186269820943
  • MellesGRde SeraJPEgginkCACruysbergJRBinderPSBilateral, anterior stromal ring opacity of the corneaBr J Ophthalmol19988255225259713059
  • TerryMAOusleyPJRapid visual rehabilitation after endothelial transplants with deep lamellar endothelial keratoplasty (DLEK)Cornea200423214315315075883
  • PriceFWJrAir lamellar keratoplastyRefract Corneal Surg1989542402432488812
  • SaraybaMAIgnacioTSTranDBBinderPSA 60 kHz IntraLase femtosecond laser creates a smoother LASIK stromal bed surface compared to a Zyoptix XP mechanical microkeratome in human donor eyesJ Refract Surg200723433133717455827
  • SaraybaMATungsiripatTSweetPMChuckRSA portable microkeratome for harvesting the human anterior corneal surfaceCornea200423544344615220727
  • SaraybaMAIgnacioTSBinderPSTranDBComparative study of stromal bed quality by using mechanical, IntraLase femtosecond laser 15- and 30-kHz microkeratomesCornea200726444645117457194
  • SaraybaMAJuhaszTChuckRSFemtosecond laser posterior lamellar keratoplasty: a laboratory modelCornea200524332833315778607
  • BinderPSLambertRWKoepnickRGLittlefieldTRComparison of the UniversalKeratome and the Automated Corneal ShaperCataract Refract Surg199622911751188
  • BinderPSMooreMLambertRWSeagristDMComparison of two microkeratome systemsJ Refract Surg19971321421539109070
  • GolchetGCarrJHarrisMGWhy don’t we have enough cornea donors? A literature review and surveyOptometry200071531832810998945
  • KitzmannASGoinsKMReedCPadnick-SilverLMacsaiMSSutphinJEEye bank survey of surgeons using precut donor tissue for Descemet stripping automated endothelial keratoplastyCornea200827663463918580252
  • ChenESTerryMAShamieNHoarKLFriendDJPrecut tissue in Descemet’s stripping automated endothelial keratoplasty donor characteristics and early postoperative complicationsOphthalmology2008115349750218221999
  • TerryMASaadHAShamieNEndothelial keratoplasty: the influence of insertion techniques and incision size on donor endothelial survivalCornea2009281243119092400
  • TerryMAShamieNChenESPhillipsPMHoarKLFriendDJPrecut tissue for Descemet’s stripping automated endothelial keratoplasty: vision, astigmatism, and endothelial survivalOphthalmology2009116224825619091414
  • RoseLBricenoCAStarkWJGloriaDGJunASAssessment of eye bank-prepared posterior lamellar corneal tissue for endothelial keratoplastyOphthalmology2008115227928617599413
  • PelsLMHTulloAEuropean Eye Bank Association Directory2000
  • SperlingSEvaluation of the endothelium of human donor corneas by induced dilation of intercellular spaces and trypan blueGraefes Arch Clin Exp Ophthalmol1986225–44284343530885
  • ThuretGCarricajoAChiquetCSensitivity and rapidity of blood culture bottles in the detection of cornea organ culture media contamination by bacteria and fungiBr J Ophthalmol200286121422142712446379
  • ThuretGCarricajoAVautrinACEfficiency of blood culture bottles for the fungal sterility testing of corneal organ culture mediaBr J Ophthalmol200589558659015834090
  • ZanettiEBruniAMucignatGCamposampieroDFrigoACPonzinDBacterial contamination of human organ-cultured corneasCornea200524560360715968169
  • RedbrakeCSallaSFrantzAChanges in human donor corneas preserved for longer than 4 weeksCornea199817162659436881
  • van der WantHJPelsESchuchardYOlesenBSperlingSElectron microscopy of cultured human corneas. Osmotic hydration and the use of a dextran fraction (dextran T 500) in organ cultureArch Ophthalmol198310112192019266197050
  • BorderieVMBaudrimontMLopezMCarvajalSLarocheLEvaluation of the deswelling period in dextran-containing medium after corneal organ cultureCornea199716922152239071536
  • WolfAHWelge-LüenUCPriglingerSOptimizing the deswelling process of organ cultured corneasCornea6200928552452919421045
  • VinciguerraPAzzoliniMAiraghiPRadicePDe MolfettaVEffect of decreasing surface and interface irregularities after photorefractive keratectomy and laser in situ keratomileusis on optical and functional outcomesJ Refract Surg1998142 SupplS199S2039571553
  • Alvarez de ToledoJAWPonzinDTuloAEEBA Minimum StandardsEuropean Eye Bank Association Homepage [article on the Internet]. 2007 [cited 2007]. http://www.europeaneyebanks.org/portalAccessed. June 26, 2012
  • GorovoyMSPrecut tissue for descemet stripping automated endothelial keratoplastyCornea200827663263318580251
  • PriceFWJrPrecut tissue for descemet stripping automated endothelial keratoplastyCornea200827663063118580250
  • TerryMAPrecut tissue for descemet stripping automated endothelial keratoplasty: complications are from technique, not tissueCornea200827662762918580249
  • PriceMOBaigKMBrubakerJWPriceFWJrRandomized, prospective comparison of precut vs surgeon-dissected grafts for descemet stripping automated endothelial keratoplastyAm J Ophthalmol20081461364118439566
  • BrownJSWangDLiXIn situ ultrahigh-resolution optical coherence tomography characterization of eye bank corneal tissue processed for lamellar keratoplastyCornea200827780281018650667
  • KomaiYUshikiTThe three-dimensional organization of collagen fibrils in the human cornea and scleraInvest Ophthalmol Vis Sci1991328224422582071337
  • OjedaJLVentosaJAPiedraSThe three-dimensional microanatomy of the rabbit and human cornea. A chemical and mechanical microdissection-SEM approachJ Anat2001199Pt 556757611760887