Infraclavicular sensor site: A new promising site for transcutaneous capnography

, , , , , , & show all
Pages 340-342 | Received 09 Apr 2011, Accepted 14 Feb 2012, Published online: 24 Mar 2012
 

Abstract

Background. Transcutaneous measurement of carbon dioxide is routinely done at the earlobe site. In patients receiving non invasive ventilation or in the intensive care setting with necklines, an alternate measurement site would be useful. We started to use the infraclavicular site for transcutaneous measurements of carbon dioxide using a new digital sensor. Aim. Comparison of transcutaneous carbon dioxide with arterial carbon dioxide at the infraclavicular site. Methods. We retrospectively compared transcutaneous carbon dioxide at the infraclavicular site with arterial carbon dioxide in 50 samples. The Sentec Digital Monitoring System (Sentec AG, Therwil, Switzerland) was used. The V-Sign digital sensor was placed on the infraclavicular site at the medial two third and one third point from the sternoclavicular joint and acromioclavicular joint. Results. When comparing PcCO2 with PaCO2 values, the Bland-Altman analysis revealed a bias of 0.02 kPa (95% CI: [− 0.1; 0.14]) with a precision of 0.42 kPa. Linear regression analysis describes the relationship between the two methods. The slope of the linear model was 0.85 ± 0.04 and the intercept was 0.77 ± 0.21 (RSE = 0.37 , R2 = 0.91). Conclusion. The measurement of transcutaneous carbon dioxide at the infraclavicular site is feasible with a digital sensor and has a good correlation with the carbon dioxide values obtained from the arterial blood gas. The findings of the current study form the basis for further clinical studies for its regular application in clinical use.

Declaration of interest: The authors report no conflict of interest. The authors alone are responsible for the content and writing of the paper.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 200.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.