Evaluation of NGAL TestTM on Cobas 6000

, &
Pages 20-26 | Received 31 Jul 2013, Accepted 12 Oct 2013, Published online: 15 Nov 2013
 

Abstract

Background. Neutrophil Gelatinase-Associated Lipocalin (NGAL) is a promising biomarker for acute kidney injury (AKI). Our objectives were to evaluate the NGAL TestTM from Bioporto for both urine NGAL and plasma NGAL on the Cobas 6000 c501 (Roche Diagnostics, Rotkreuz, Switzerland) with matched measurements run on Hitachi 917, the method's linearity on the Cobas 6000 in urine, EDTA and Lithium-Heparin (Li-Hep), the influence of using EDTA or Li-Hep tubes and, finally, the impact of freezing and thawing on the sample. Methods. Forty matched samples of Li-Hep and EDTA plasma and 40 urine samples were analyzed for method, anticoagulant, and freeze-thaw comparisons. Linearity was assessed using high NGAL samples diluted in urine, EDTA, and Li-Hep plasma. Commercial internal controls were used for the imprecision study. Results. The Cobas 6000 measured identically with the Hitachi 917, however, not in EDTA plasma (MedianDifference = 17.50 μg/L, p < 0.0001). Freeze-thaw process reduced NGAL ((EDTA: MeanDifference = = 15.13 μg/L, p = 0.0014)(Li-Hep: MedianDifference = = 6.5 μg/L, p = 0.0129)). NGAL results were higher in Li-Hep plasma than in EDTA plasma ((Non-thawed: MedianDifference = = 14.5 μg/L, p < 0.0001), (Thawed: MedianDifference = = 21.5 μg/L, p = 0.0003)). Linearity agreements were observed in all three specimens. Imprecision (CV%) was below 3%. Conclusion. The NGAL TestTM can be applied on the Cobas 6000 with acceptable performance, although the Cobas 6000 measured higher than the Hitachi 917 in EDTA plasma. Though clinically insignificant, we found that the freeze-thaw process had a reduced effect. NGAL results were higher in Li-Hep tubes than in EDTA tubes. Thus, for blood samples we recommend use of EDTA tubes for NGAL measurements.

Declaration of interest: The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the paper.

All reagents, calibrators and controls were provided by BioPorto Diagnostics. For the laboratory work, the laboratory technician's salary was funded by BioPorto Diagnostics.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 200.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.