Enduragen Patch Grafts for Exposed Orbital Implants

, MD, PhD, , MD, , MD, PhD, , MD & , MD
Pages 92-95 | Received 21 Sep 2010, Accepted 24 Jan 2011, Published online: 26 Mar 2011
 

Abstract

Purpose: To present a new technique using the recently introduced Enduragen® material (Tissue Science Laboratories) as a patch graft for exposed ocular implants.

Methods: A retrospective, interventional, non-comparative case series of 3 patients who had Enduragen patch grafts for the closure of Tenon’s capsule and conjunctiva over exposed ocular implants. Medical records were reviewed and the following parameters were collected: age, gender, indication for surgery, type of surgery, laterality, type of orbital implant, complications after repair and length of follow-up.

Results: Three patients were identified, 2 males and 1 female. One patient had a secondary quad-motility implant with supertemporal exposure. The second patient had a secondary implant with a fistula at the lateral aspect of the socket. The third patient had a centrally exposed primary hydroxyapatite implant. All patients received Enduragen patch grafts to cover the implant. Follow up ranged from 40 to 43 months (mean, 41.3 months; SD, ± 1.5). None of the 3 patients had any signs of implant re-exposure at the time of the last post-operative visit. There were no intra-operative or early complications observed.

Conclusions: This consecutive case series suggests that Enduragen could be used as a safe and effective patch graft for exposed ocular implants. However, a larger prospective study with longer follow-up would be useful in further defining the indications and limitations of the Enduragen patch graft for the treatment of exposed orbital implants.

Declaration of interests: Dr. John D. McCann is the creator of the McCann Medical Matrix and has a financial interest in the software. Dr. Richard L. Anderson is the designer of the QUAD motility implant and has a financial interest in this product. There are no methods of funding to disclose. The authors alone are responsible for the content and writing of the paper.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 733.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.