Comparative study of three flexiVent system configurations using mechanical test loads

, , &
Pages 84-92 | Received 01 Apr 2014, Accepted 29 Sep 2014, Published online: 14 Nov 2014
 

ABSTRACT

The sole commercial system currently employing the forced oscillation technique (FOT) in small laboratory animals (flexiVent; SCIREQ Inc., Canada) was recently redesigned along with its operating software. Yet, many users still work with the legacy version or a mixed configuration. This study aimed to compare result accuracy and precision between three flexiVent system configurations and to quantify the impact of configuration changes on measured parameters. Physiologically relevant resistance or elastance were measured at 2.5 Hz on the following three system configurations using characterized mechanical test loads: (i) legacy flexiVentflexiVent v5.3.4 (Leg-fV5), (ii) legacy flexiVentflexiWare v7.2.1 (Leg-fW7), and (iii) flexiVent FX—flexiWare v7.2.1 (FX-fW7). Results demonstrated measurements of high precision that were consistent between system configurations. There was no statistical difference between system configurations in terms of measuring a predicted resistance. Measurements of elastance, on the other hand, were configuration-sensitive with FX-fW7 generating values that were closer to theoretical ones than the other two configurations. The largest impact on measurement outcomes was associated with the most noteworthy configuration change (i.e., software and hardware replacement). This effect was however constrained, with variations in the order of 3–5%, approximately. In conclusion, the latest version of the sole commercial pre-clinical FOT system currently available generated results that were equivalent or better than those acquired with two other system configurations. Given that configuration changes were associated with subtle parameter differences, best practice would recommend consistency within a study and reporting the full details of the system used.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.