Comparison of Application Systems for Autologous Serum Eye Drops

, , , &
Pages 571-579 | Received 24 Jun 2013, Accepted 05 Oct 2013, Published online: 08 Jan 2014
 

Abstract

Purpose: Autologous serum eye drops are used for therapy of severe ocular surface disorders by patients with visual and manual impairments. Until recently, they were prepared under sterile conditions from open blood sampling systems. Closed blood donation systems simplify production. This study compares handling and costs of a new day dosage vial (“Meise-vial”) and a single-dose tube system (“Maco-tube”) based on closed production systems with conventional dropper bottles.

Methods: Nonimpaired volunteers and patients with visual or manual impairment (n = 10 each group) single-handedly tested the applicators filled with 1.5 ml sterile isotonic saline solution. Participants rated convenience of opening the containers and applying eye drops on a scale from 1.0 (very good) to 6.0 (very bad). Number of retrievable drops was counted. Participants were asked which system they prefer, both with and without knowledge of the price for the systems.

Results: The median for convenience of opening (eye drop application) was 2.0 (1.0) for Meise-vials, 5.0 (4.0) for Maco-tubes, and 2.0 (2.0) for dropper bottles (p < 0.001). Median number of drops retrieved from the systems was 30.5 (vials), 2 (tubes), and 30 (bottles). Ranking did not differ between nonimpaired and impaired participants. Assuming equal prices, 16 participants chose Meise-vials, 14 dropper bottles, and no tubes. With knowledge of pricing, preference changed (p = 0.001), 20 participants (67%) opted for dropper bottles and 5 (17%) preferred the other containers.

Conclusion: Convenience of opening, applying eye drops, and number of drops retrieved was substantially better for dropper bottles and Meise-vials compared with Maco-tubes. Bottles and vials were equally well received. With regard to price, nonimpaired as well as impaired participants preferred dropper bottles. While closed systems simplify production, patients preferred dropper bottles for daily application of autologous serum eye drops for a number of reasons.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 555.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.