The new INNOVANCE® PFA P2Y cartridge is sensitive to the detection of the P2Y12 receptor inhibition

, , , , , , , , & show all
Pages 19-25 | Received 24 Jul 2010, Accepted 09 Aug 2010, Published online: 27 Sep 2010
 

Abstract

Insufficient response on antiplatelet medication has become an intensively discussed issue because of the risk factor of recurrent adverse cardiovascular events. However, the monitoring of antiplatelet therapy requires appropriate, robust and reliable test methods. For the measurement of thienopyridine effects, the manufacturer of the PFA-100® System provides the INNOVANCE® PFA P2Y cartridge. We tested this cartridge for its capacity to detect the inhibition of the P2Y12 receptor, which is the target for thienopyridine medication (e.g. clopidogrel). We compared the INNOVANCE® PFA P2Y results with those obtained by the receptor specific flow cytometric vasodilator stimulated phosphoprotein (VASP) assay that expresses the status of the P2Y12 receptor as “platelet reactivity index” (PRI). The in vitro addition of the P2Y12 receptor antagonist cangrelor (AR-C69931MX) to citrated human whole blood resulted in a dose-dependent prolongation of closure times (CTs) of the INNOVANCE® PFA P2Y cartridge correlating with decreased PRI levels. In volunteers, the intake of a 600 mg clopidogrel loading dose caused an increase of the CTs in all volunteers, although some of these volunteers were identified as “poor responders” by the VASP assay (no significant reduction of PRI levels). In 50 patients with stable coronary artery disease undergoing percutaneous coronary intervention (PCI) and under dual antiplatelet therapy, the new cartridge had a detection rate of 84% (CT 106 s as cut-off) for clopidogrel medication. After dividing the 50 patients into two groups according to their response to clopidogrel INNOVANCE® PFA P2Y recognized all “responders” (defined by a PRI > 50%) using >106 s as cut-off but the specificity for a “good response” was only 42% because several “poor responders” (defined by a PRI > 50%) also showed CTs above the cut-off. The best correlation (substantial agreement) between the results of INNOVANCE® PFA P2Y and of the VASP phosphorylation assay was achieved using CT > 200 s and PRI < 55% as cut-offs. Then, the sensitivity of INNOVANCE® PFA P2Y was 97% and the specificity for a “good response” 65%. In summary, INNOVANCE® PFA P2Y showed a high sensitivity for the detection of P2Y12 receptor blockade, but had only a limited specificity for a “good response” to clopidogrel. Therefore, this new cartridge is a useful tool to rule out P2Y12 receptor inhibition, if normal or only slightly prolonged CTs are obtained. Its predictive value for risk assessment of thromboembolic events, e.g. after coronary stent implantation, needs to be evaluated in clinical trials.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.