Validation of intravascular ultrasound for measurement of aortic diameters: Comparison with multi-detector computed tomography

, , , , , , , , , & show all
Pages 289-295 | Received 22 Jan 2015, Accepted 03 May 2015, Published online: 12 Jun 2015
 

Abstract

Introduction: Intravascular ultrasound (IVUS) provides real-time imaging of aortic pathology during aortic interventions. The objective of the present study was to validate IVUS measurements using computed tomography (CT) angiography in a sufficiently large cohort. Material and methods: From October 2010 to February 2014, 57 consecutive patients with acute aortic syndrome underwent both IVUS and spiral CT for a total of 509 comparable thoracic aorta segments. Minimum, maximum, and mean diameters were determined at each measurement point. Results: IVUS measurements of the thoracic aorta (aortic root, brachiocephalic trunk, left common carotid artery, left subclavian artery) ranged from 18–48.5 (mean 33.0) mm, versus 18–48.4 (mean 31.7) mm on CT, with a significant mean difference of 5.1% (p < 0.05). The correlation between methods was generally good, but IVUS tended toward larger diameters than CT in the aortic arch, especially the left subclavian artery. In 78% of measurement sites, total mean diameters were larger on IVUS measurements of the thoracic aorta than on CT measurements. Conclusion: IVUS is a reliable tool for measuring aortic diameter, especially in the descending part of the aorta. However, its pitfalls must be considered to prevent choosing an incorrectly sized stent graft in the acute setting of thoracic endovascular aortic repair.

Declaration of interests: RAJ and RE have received speaker’s honoraria from Volcano Corporation.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 344.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.