Are there any differences in three-dimensional placental vascular indices obtained using conventional power Doppler and high-definition flow imaging?

, , , , &
Pages 1664-1667 | Received 01 Oct 2011, Accepted 19 Dec 2011, Published online: 14 Feb 2012
 

Abstract

Objective: The purpose of this study was to determine whether there are differences in values and reproducibility of three-dimensional (3D) vascular indices obtained on placental volumes using power Doppler (PD) or high-definition flow imaging (HDFI) techniques. Methods: A prospective study was performed on 121 uncomplicated singleton pregnancies at 11 + 0 to 13 + 6 weeks of gestation. Two placental volumes were acquired from each pregnancy. Vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were then analyzed and compared. In order to assess the reproducibility of the measurements, two additional placental volumes obtained with both PD and HDFI were acquired in 31 pregnancies and the agreement assessed by intraclass correlation coefficients. Inter-observer variability was assessed by analyzing all the volumes by two observers blinded to each other’s. Results: A significant relationship was observed between the vascular indices values obtained with the two techniques (VI Pearson’s r = 0.891 p < 0.001; FI r = 0.769 p < 0.001; VFI r = 0.847 p < 0.001). The median values of VI, FI and VFI were significantly higher when obtained with HDFI imaging. In serial recordings, the ICCs resulted higher when volumes were acquired with HDFI rather than with PD techniques. Similarly, HDFI demonstrated a higher inter-observer reproducibility. Conclusions: 3D vascular indices calculated using HDFI are higher than those calculated using conventional PD. Although the relationship between the two methods is high, HDFI shows a better reproducibility suggesting its potential clinical application.

Declaration of Interest: The authors report no conflicts of interest.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.