Effect of static force on bone conduction hearing thresholds and comfort

, &
Pages 632-635 | Received 30 Nov 2010, Accepted 24 Dec 2010, Published online: 21 Apr 2011
 

Abstract

Abstract

Objective: To assess the effect of the static force of a bone vibrator on the results of bone conduction (BC) threshold measurements and comfort. Design: BC thresholds were determined for 40 participants using the standardized P-3333 headband and a leather adjustable headstrap with variable static forces (2.4, 3.4, 4.4, 5.4 N). Comfort ratings were examined using a five-point Likert scale. Results: Mean BC thresholds were within ± 2 dB across all conditions; differences may be considered small enough to be clinically insignificant. Participants experienced significantly greater discomfort with the P-3333 versus the adjustable headstrap. The mean static force of the P-3333 varied considerably and was higher in situ than the calibration standard of 5.4 N. Conclusions: The results suggest that future revisions of relevant international and national standards should address the use of an adjustable headstrap and a static force less than 5.4 N.

Sumario

Objetivo: Evaluar el efecto de la fuerza estática de un vibrador óseo en los resultados de las mediciones de los umbrales por conducción ósea (BC) y sobre la comodidad. Diseño: Se determinaron los umbrales BC en 40 participantes utilizando la diadema estandarizada P-3333 y una banda cefálica ajustable con fuerzas estáticas variables (2.4, 3.4, 4.4, 5.4 N). La calificación de la comodidad se examinó con una escala Likert de cinco puntos. Resultados: Los umbrales promedio estuvieron en los ± 2dB a través de todas las condiciones; las diferencias pueden ser consideradas lo suficientemente pequeñas para ser clínicamente insignificantes. Los participantes experimentaron una molestia mucho mayor con la P-3333 que con la banda cefálica ajustable. La fuerza estática de la P-3333 varió considerablemente y fue mayor in situ que en el estándar de calibración de 5.4 N. Conclusiones: Los resultados sugieren que las revisiones de los estándares internacionales y nacionales deben dirigir la atención al uso de las bandas cefálicas ajustables y una fuerza estática menor que 5.4 N.

Acknowledgements

The authors thank Dr. Stephen Pallett for assistance.

Declaration of interest: The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the paper.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 194.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.