1,065
Views
119
CrossRef citations to date
0
Altmetric
Research Article

European multi-centre study of the Nucleus Hybrid L24 cochlear implant

, , , , , , , , , , , , , , , , & show all
Pages 838-848 | Received 29 Oct 2012, Accepted 30 Apr 2013, Published online: 02 Sep 2013
 

Abstract

Objectives: To investigate the preservation of residual hearing in subjects who received the Nucleus Hybrid L24 cochlear implant. To investigate the performance benefits up to one year post-implantation in terms of speech recognition, sound quality, and quality of life. Design: Prospective, with sequential enrolment and within-subject comparisons. Post-operative performance using a Freedom Hybrid sound processor was compared with that of pre-operative hearing aids. Study sample: Sixty-six adult hearing-impaired subjects with bilateral severe-to-profound high frequency hearing loss. Results: Group median increase in air-conduction thresholds in the implanted ear for test frequencies 125–1000 Hz was < 15 dB across the population; both immediately and one year post-operatively. Eighty-eight percent of subjects used the Hybrid processor at one year post-op. Sixty-five percent of subjects had significant gain in speech recognition in quiet, and 73% in noise (≥ 20 percentage points/2 dB SNR). Mean SSQ subscale scores were significantly improved (+ 1.2, + 1.3, + 1.8 points, p < 0.001), as was mean HUI3 score (+ 0.117, p < 0.01). Combining residual hearing with CI gave 22−26 %age points mean benefit in speech recognition scores over CI alone (p < 0.01). Conclusions: Useful residual hearing was conserved in 88% of subjects. Speech perception was significantly improved over preoperative hearing aids, as was sound quality and quality of life.

Acknowledgements

The authors acknowledge the hard work of the unlisted members of clinical teams, and the subjects recruited to the study. We thank the journal's reviewers for their helpful comments.

Declaration of interest: This study was sponsored by Cochlear AG, Basel, Switzerland. CJ and JP are employees of Cochlear Corporation, the manufacturer of the device studied. The remaining authors report no conflicts of interest.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 194.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.