278
Views
26
CrossRef citations to date
0
Altmetric
Original Article

Osteosynthesis of femoral neck fracture: The sliding-screw-plate with or without compression

, , &
Pages 620-623 | Published online: 08 Jul 2009
 

Abstract

In a prospective study of 220 displaced femoral neck fractures treated with a sliding-screw-plate, the cases were allocated to osteosynthesis with or without compression. In surviving patients followed for at least 1 year, union occurred in 57/85 with compression and 58/71 without compression. At 2 years, necrosis was radiographically evident in 9/37 and 7/36 united fractures. Thus, compression cannot be recommended when displaced femoral neck fractures are treated with a sliding-screw-plate.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.