References
- Briggs RJ, Tykocinski M, Stidham K. Cochleostomy site: implications for electrode placement and hearing preservation. Acta Otolaryngol 2005; 125: 870–6
- Todt I, Basta D, Ernst A. Does the surgical approach in cochlear implantation influence the occurrence of postoperative vertigo?. Otolaryngol Head Neck Surg 2008; 138: 8–12
- Steenerson RL, Gary LB, Wynens MS. Scala vestibuli cochlear implantation for labyrinthine ossification. Am J Otol 1990; 11: 360–3
- Kiefer J, Weber A, Pfennigdorff T, von Ilberg C. Scala vestibuli insertion in cochlear implantation: a valuable alternative for cases with obstructed scala tympani. ORL J Otorhinolaryngol Relat Spec 2000; 62: 251–6
- Bacciu S, Bacciu A, Pasanisi E, Vincenti V, Guida M, Barbot A, et al. Nucleus multichannel cochlear implantation in partially ossified cochleas using the Steenerson procedure. Otol Neurotol 2002; 23: 341–5
- Aschendorff, A, Kromeier, J, Klenzner, T, Laszig, R. Quality control after insertion of the nucleus contour and contour advance electrode in adults. Ear Hear 2007;28(2 Suppl):75S–79S.
- Skinner MW, Holden TA, Whiting BR, Voie AH, Brunsden B, Neely JG, et al. In vivo estimates of the position of advanced bionics electrode arrays in the human cochlea. Ann Otol Rhinol Laryngol Suppl 2007; 197: 2–24
- Roland PS, Wright CG, Isaacson B. Cochlear implant electrode insertion: the round window revisited. Laryngoscope 2007; 117: 1397–402
- Adunka OF, Buchman CA. Scala tympani cochleostomy I: results of a survey. Laryngoscope 2007; 117: 2187–94
- Adunka OF, Radeloff A, Gstoettner WK, Pillsbury HC, Buchman CA. Scala tympani cochleostomy II: Topography and histology. Laryngoscope 2007; 117: 2195–200
- Hüttenbrink KB, Zahnert T, Jolly C, Hofmann G. Movements of cochlear implant electrodes inside the cochlea during insertion: an x-ray microscopy study. Otol Neurotol 2002; 23: 187–91
- Postnov A, Zarowski A, De Clerck N, Vanpoucke F, Offeciers FE, Van Dyck D, et al. High resolution micro-CT scanning as an innovative tool for evaluation of the surgical positioning of cochlear implant electrodes. Acta Otolaryngol 2006; 126: 467–74
- Lane JI, Driscoll CL, Witte RJ, Primak AN, Lindell EP. Scalar localization of the electrode array after cochlear implantation: a cadaveric validation study comparing 64-slice multidetector computed tomography with microcomputed tomography. Otol Neurotol 2007; 28: 191–4
- Wagner, J, Rademacher, G, Ernst, A, Todt, I., Evaluation of cochlear implant electrode position in the temporal bone by 64-slice computed tomography. HNO 2008, (in press).
- Aschendorff A, Kubalek R, Hochmuth A, Bink A, Kurtz C, Lohnstein P, et al. Imaging procedures in cochlear implant patients – evaluation of different radiological techniques. Acta Otolaryngol Suppl 2004; 552: 46–9
- Aschendorff A, Kubalek R, Turowski B, Zanella F, Hochmuth A, Schumacher M, et al. Quality control after cochlear implant surgery by means of rotational tomography. Otol Neurotol 2005; 26: 34–7
- Lane JI, Witte RJ, Driscoll CL, Shallop JK, Beatty CW, Primak AN. Scalar localization of the electrode array after cochlear implantation: clinical experience using 64-slice multidetector computed tomography. Otol Neurotol 2007; 28: 658–62
- Nadol JB, Jr, Shiao JY, Burgess BJ, Ketten DR, Eddington DK, Gantz BJ, et al. Histopathology of cochlear implants in humans. Ann Otol Rhinol Laryngol 2001; 110: 883–91
- Stöver T, Issing P, Graurock G, Erfurt P, ElBeltagy Y, Paasche G, et al. Evaluation of the advance off-stylet insertion technique and the cochlear insertion tool in temporal bones. Otol Neurotol 2005; 26: 1161–70