References
- Håkansson B, Tjellström A, Rosenhall U, et al. The bone-anchored hearing aid. Principal design and a psychoacoustical evaluation. Acta Otolaryngol. 1985;100(3–4):229–239.
- Wazen JJ, Spitzer JB, Ghossaini SN, et al. Transcranial contralateral cochlear stimulation in unilateral deafness. Otolaryngol Head Neck Surg. 2003;129(3):248–254.
- Kompis M, Pfiffner F, Krebs M, et al. Factors influencing the decision for Baha in unilateral deafness: the Bern Benefit in single-sided deafness questionnaire. Adv Otorhinolaryngol. 2011;71:103–111.
- Kurz A, Flynn M, Caversaccio M, et al. Speech understanding with a new implant technology: a comparative study with a new nonskin penetrating Baha system. Biomed Res Int. 2014;2014:1.
- Rigato C, Reinfeldt S, Håkansson B, et al. Effect of transducer attachment on vibration transmission and transcranial attenuation for direct drive bone conduction stimulation. Hear Res. 2019;381:107763.
- Mertens G, Desmet J, Snik AFM, et al. An experimental objective method to determine maximum output and dynamic range of an active bone conduction implant: the bonebridge. Otol Neurotol. 2014;35:1126–1130.
- Wimmer W, von Werdt M, Mantokoudis G, et al. Outcome prediction for Bonebridge candidates based on audiological indication criteria. Auris Nasus Larynx. 2019;46(5):681–686.
- Kuk F, Peeters H, Lau C, et al. Effect of maximum power output and noise reduction on speech recognition in noise. J Am Acad Audiol. 2011;22(5):265–273.
- Rahne T, Plontke SK. Device-based treatment of mixed hearing loss: An audiological comparison of current hearing systems. HNO. 2016;64(2):91–100.
- van Barneveld DCPBM, Kok HJW, Noten JFP, et al. Determining fitting ranges of various bone conduction hearing aids. Clin Otolaryngol. 2018;43(1):68–75.
- Zwartenkot JW, Snik AF, Mylanus EA, et al. Amplification options for patients with mixed hearing loss. Otol Neurotol. 2014;35(2):221–226.
- Bosman AJ, Kruyt IJ, Mylanus EAM, et al. On the evaluation of a superpower sound processor for bone-anchored hearing. Clin Otolaryngol. 2018;43(2):450–455.
- Bosman AJ, Snik FM, Mylanus EA, et al. Fitting range of the BAHA Intenso. Int J Audiol. 2009;48(6):346–352.
- Hol MK, Nelissen RC, Agterberg MJ, et al. Comparison between a new implantable transcutaneous bone conductor and percutaneous bone-conduction hearing implant. Otol Neurotol. 2013;34(6):1071–1075.
- Kurz A, Flynn M, Good T, et al. Influence of loudness compression on hearing with bone anchored hearing implants. Int J Med Pharm Sci Eng. 2014;8(1):1–6.
- Carlsson P, Håkansson B, Ringdahl A. Force threshold for hearing by direct bone conduction. J Acoust Soc Am. 1995;97(2):1124–1129.
- Kompis M, Krebs M, Häusler R. Verification of normative values for the Swiss version of the Freiburg speech intelligibility test. HNO. 2006;454:445–450.
- Wagener KB, Brand T. Development and evaluation of a German sentence test Part III: Evaluation of the Oldenburg sentence test. Audiol. Acoust. 1999;38:86–95.
- Munziger M. Reference values for speech reception thresholds and assessment of noise diffusivity in multi-channel noise. Master thesis, Medical School, University of Bern 2017.
- Pfiffner F, Kompis M, Stieger C. Bone anchored hearing aids: correlation between pure tone thresholds and outcome in three users groups. Otol Neurotol. 2009;30(7):884–890.